Mid-high Voltage Ceramic Capacitors
Disk type with lead
Safety standard approved
CD series
Issue date:
October 2011
• All specifications are subject to change without notice.
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
(1/2)
Mid-high Voltage Ceramic Capacitors(Disk with Lead)
Safety Standard Approved CD Series
Conformity to RoHS Directive
REINFORCED INSULATION TYPE/Operating temperature range: –25 to +105°C(UL standard: –25 to +85°C)
CLASS 2 HIGH DIELECTRIC
FEATURES
• Flame-resistant reinforced outer insulation prevents fires, electri-
cal shock, and other potential hazards.
• Compliant with the safety standards of 11 countries.
• This ceramic capacitor meets European Class II (reinforced
insulation) Safety Standards VDE, SEV, SEMKO, BS. Since it is
rated at a withstand voltage of AC.4000V, it can be used in
single-unit configurations within European Class II devices.
• This product is compatible with halogen-free external resin
coating (we recommend halogen-free products as standard).
CAPACITANCE TEMPERATURE CHARACTERISTICS
AND TOLERANCE
Temperature characteristics
B(±10%)
E(+20, –55%)
Test temperature
range
–25 to +85°C
–25 to +85°C
Capacitance
tolerance
K(±10%)
M(±20%)
PRODUCT IDENTIFICATION
CD 12 -E 2GA 222 M Y N S A
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
(1) Type
(2) Shape
(3) Capacitance temperature characteristics
(4) Rated voltage
(5) Nominal capacitance
(6) Capacitance tolerance
(7) Class
(8) Lead type
(9) Safety standard
(10) Halogen-free compatible product
CAPACITANCE AND DIMENSIONS
Part No.
Halogen-free product
CD70-B2GA101KY
CD70-B2GA151KY
CD85-B2GA221KY
CD90-B2GA331KY
CD90-B2GA391KY
CD95-B2GA471KY
CD75-E2GA681MY
CD85-E2GA102MY
CD10-E2GA152MY
CD12-E2GA222MY
CD14-E2GA332MY
CD15-E2GA392MY
CD16-E2GA472MY
∗
∗
SA
Current product
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
CD70-B2GA101KY
CD70-B2GA151KY
CD85-B2GA221KY
CD90-B2GA331KY
CD90-B2GA391KY
CD95-B2GA471KY
CD75-E2GA681MY
CD85-E2GA102MY
CD10-E2GA152MY
CD12-E2GA222MY
CD14-E2GA332MY
CD15-E2GA392MY
CD16-E2GA472MY
∗
S
Capacitance
temperature
characteristics
S
S
S
S
S
S
S
S
S
S
S
S
Capacitance
(pF)
100
150
220
330
390
470
680
1,000
1,500
2,200
3,300
3,900
4,700
Capacitance
tolerance
K(±10%)
K(±10%)
K(±10%)
K(±10%)
K(±10%)
K(±10%)
M(±20%)
M(±20%)
M(±20%)
M(±20%)
M(±20%)
M(±20%)
M(±20%)
Dimensions(mm)
D max. T max. F
7.0
7.0
8.5
9.0
9.0
9.5
7.5
8.5
10.0
11.5
13.5
14.5
15.5
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
10+2, –1
10+2, –1
10+2, –1
10+2, –1
10+2, –1
10+2, –1
10+2, –1
10+2, –1
10+2, –1
10+2, –1
10+2, –1
10+2, –1
10+2, –1
d
0.6±0.05
0.6±0.05
0.6±0.05
0.6±0.05
0.6±0.05
0.6±0.05
0.6±0.05
0.6±0.05
0.6±0.05
0.6±0.05
0.6±0.05
0.6±0.05
0.6±0.05
B(±10%)
E(+20, –55%)
: Lead shape symbol
LIST OF STANDARD LEAD SHAPES
The lead type is indicated by the letter which is the 15th character of the product name.
Example) TDK Product Name:
CD12-E2GA222MYNSA
N: Lead type (Vertical kink, Short)
Dimensions in mm
Long lead
Symbol G
D
T
4max.
Short lead
Symbol N
D
T
4max.
d
5±1
F
Vertical kink
25min.
F
d
• We recommend using a vertical kink type.
• For bulk products, we recommend a short lead type with the symbol N.
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
• All specifications are subject to change without notice.
005-03 / 20111003 / e4b3_cd.fm
(2/2)
HALOGEN-FREE PRODUCT
MARKINGS
Item
1. Series
2. Nominal capacitance
3. Capacitance tolerance
4. Rated voltage Eac
5. Sub-class of safety performance
6. TDK’s logogram
7. Date code
∗
∗
Marking examples
CD
222(2200pF)
M(±20%)
(AC.250V)
250V
X1Y1
15 (2011.5)
∗
CD222M
250
X1Y1
15
(Marking position is reference.)
Year and month of production: last digit of year + month denoted by 1, 2, 3, 4, 5, 6, 7, 8, 9, O (October), N (November), or D (December).
The expression has become simplified due to a revision in the standards.
INTERNATIONALLY CERTIFIED STATUS / IEC60384-14 EN60384-14 Approved
Safety
standard
BSI
VDE
SEV
SEMKO
NEMKO
DEMKO
FIMKO
IMQ
SAA
UL
CSA
CQC
Standard No.
of IEC
IEC 60065
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60065
—
Standard No.
BS EN 60065
BS EN60384-14
EN 60384-14
EN 60384-14
EN 60384-14
EN 60384-14
EN 60384-14
EN 60384-14
EN 60384-14
AS3250
UL 1414
Temperature Insulation
characteristics sub-class
B, E
B, E
B, E
B, E
B, E
B, E
B, E
B, E
B, E
B, E
B, E
B, E
X1, Y1
X1, Y1
X1, Y1
X1, Y1
X1, Y1
X1, Y1
X1, Y1
X1, Y1
—
(X, Y)
(X, Y)
X1, Y1
Rated voltage
Eac(V)
250
250
250
250
250
250
250
250
400
250
250
250
Approval report No.
Japan
Taiwan
KM37103
40029780
10.0121
912465
P09211658
315294-01
FI 25522
V3691
CS6268
E37861
2278970
(LR 35801)
CQC10001051611
KM37103
40029780
10.0121
912465
P09211658
315294-01
FI 25522
V3691
CS6268
E37861
2278970
(LR 35801)
CQC10001051638
Xiamen
KM37103
40029780
10.0121
912465
P09211658
315294-01
FI 25522
V3691
CS6268
E37861
2278970
(LR 35801)
CQC03001004816
IEC 60384-14 CAN/CSA-E60384-14
IEC 60384-14 GB-T 14472-1998
• Certificate numbers shall be changed owing to the revisions of the related standards.
CURRENT PRODUCT
MARKINGS
Item
1. Series
2. Nominal capacitance
3. Capacitance tolerance
4. Rated voltage Eac
5. Withstand voltage Eac
6. Sub-class of safety performance
7. TDK’s logogram
8. Date code
9. Regulatory body safety standards compliance markings
BSI
(U.K.)
SEMKO
(Sweden)
VDE
(Germany)
∗
Marking examples
CD
222(2200pF)
M(±20%)
(AC.250V)
250V
(AC.4kV )
T4KV
X1Y1
15 (2011.5)
∗
(Marking position of the monogram is reference.)
NEMKO
(Norway)
IMQ
(Italy)
Front
CD222M
250V
X1Y1
Back
BSI
T4KV
TJ508
94
BSI
SEV
(Switzerland)
UL
(U.S.A.)
CSA
(Canada)
TJ508
FIMKO
(Finland)
DEMKO
(Denmark)
Year and month of production: last digit of year + month denoted by 1, 2, 3, 4, 5, 6, 7, 8, 9, O (October), N (November), or D (December).
INTERNATIONALLY CERTIFIED STATUS / IEC60384-14 EN60384-14 Approved
Safety
standard
BSI
VDE
SEV
SEMKO
NEMKO
DEMKO
FIMKO
IMQ
SAA
UL
CSA
Standard No.
of IEC
IEC 60065
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60384-14
IEC 60065
—
—
Standard No.
BS EN 60065
BS EN60384-14
EN60384-14
EN60384-14
EN60384-14
EN60384-14
EN60384-14
EN60384-14
EN60384-14
AS3250
UL 1414
CSA C22.2 No.0 & No.1
Temperature
characteristics
B, E
B, E
B, E
B, E
B, E
B, E
B, E
B, E
B, E
B, E
B, E
Insulation
sub-class
X1, Y1
X1, Y1
X1, Y1
X1, Y1
X1, Y1
X1, Y1
X1, Y1
X1, Y1
—
(X, Y)
(X, Y)
Rated voltage
Eac(V)
250
250
250
250
250
250
250
250
400
250
250
Approval report No.
Japan
Taiwan
226495
138526
09.0963
915564
P09211509
315180-01
FI 25452
V3691
6268
E37861
LR35801
226495
138550
09.0963
915564
P09211509
315180-01
FI 25452
V3691
6268
E37861
LR65972
Xiamen
226495
124321
09.0963
915396
P08209310
314712-02
FI 24307
V3691
6268
E37861
LR65972
• Certificate numbers shall be changed owing to the revisions of the related standards.
• For more information about products with other capacitance or other data, please contact us.
• All specifications are subject to change without notice.
005-03 / 20111003 / e4b3_cd.fm