date
page
05/03/2013
1 of 3
MODEL:
CT-1205C-SMT
│
DESCRIPTION:
MAGNETIC BUZZER INDICATOR
FEATURES
• high sound pressure level
• washable
• internally driven
RoHS
SPECIFICATIONS
parameter
rated voltage
operating voltage
current consumption
rated frequency
sound pressure level
dimensions
weight
material
terminal
operating temperature
storage temperature
RoHS
Note:
conditions/description
min
4.0
2,100
typ
5.0
max
7.0
30
units
Vdc
Vdc
mA
Hz
dBA
mm
g
2,400
94
2.0
2,700
at 10 cm (A-weight free air), rated voltage
12.8 x 12.8 x 10.0
PPS (S-206)
SMT type (Sn plating)
90
-30
-40
yes
70
85
°C
°C
Add suffix “-TR” to the model for tape & reel packaging
SOLDERABILITY
parameter
reflow soldering
conditions/description
see reflow profile
min
typ
max
260
units
°C
PeakTemp 260°C
255°C
20~40sec
217°C
C
150°C
2
00°C
60~180sec
60 ~150
sec
Time [sec]
cui.com
CUI Inc
│
MODEL:
CT-1205C-SMT
│
DESCRIPTION:
MAGNETIC BUZZER INDICATOR
date
05/03/2013
│
page
2 of 3
MECHANICAL DRAWING
units: mm
tolerance: ±0.5 mm
RECOMMENDED
PCB LAYOUT
(Top View)
CT-1205C
0112
CHINA
PERFORMANCE CURVES
Voltage vs. Sound Pressure Level
Voltage vs. Current Consumption
MEASUREMENT METHOD
cui.com
CUI Inc
│
MODEL:
CT-1205C-SMT
│
DESCRIPTION:
MAGNETIC BUZZER INDICATOR
date
05/03/2013
│
page
3 of 3
REVISION HISTORY
rev.
1.0
1.01
1.02
description
initial release
new template applied, corrected performance curves
updated part number, added TR package option
date
09/21/2006
12/18/2012
05/03/2013
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.