Monitoring Relays
1-Phase AC/DC Current/Voltage
Type S 180
• AC/DC current/voltage control relay
• Code module for 7 current ranges (1 mA - 5A)
• Code module for 13 voltage ranges (50 mV - 500 V)
• Switch for selection of AC/DC measuring
• Built-in adjustable timer function: delay on operate
and delay on release
• Maximum or minimum level detection
• Latching at set point possible
• Output: 10 A SPDT relay
• Plug-in type module
• S-housing
• LED-indication for power supply and output ON
• AC power supply
Product Description
Universal AC/DC current and
plug-in voltage metering relay.
Built-in time delay with both
delay on operate and on rele-
ase. Exchangeable module for
different ranges and values.
Latch function and external
adjustment of hysteresis. For
a wide range of applications.
Ordering Key
Housing
Type
Output
Power supply
S 180 156 024
Type Selection
Plug
Circular
Output
SPDT
Supply: 24 VAC
S 180 156 024
Supply: 115 VAC
S 180 156 115
Supply: 230 VAC
S 180 156 230
Type Selection - Volt. Code Module
Type
SMK8001 50mV
SMK8001 60mV
SMK8001 100mV
SMK8001 150mV
SMK8001 1V
SMK8001 2.5V
SMK8001 4V
p
SMK8001 10V
SMK8001 25V
SMK8001 50V
SMK8001 150V
SMK8001 300V
SMK8001 500V
Voltage
range
10-50 mV
12-60 mV
20-100 mV
30-150 mV
0.2-1 V
0.5-2.5 V
0.8-4 V
p
, MI
input
2-10 V
5-25 V
10-50 V
30-150V
60-300 V
100-500 V
Max.
voltage
1V
1V
2V
2V
10 V
30 V
50 V
p
50 V
100 V
150 V
250 V
500 V
600 V
Input im-
pedance
1 kΩ
1 kΩ
4.7 kΩ
10 kΩ
70 kΩ
70 kΩ
70 kΩ
470 kΩ
470 kΩ
470 kΩ
1 MΩ
1 MΩ
1 MΩ
Ordering Key
Code module
Type
Measuring range
SMK8001 50mV
Type Selection - Cur. Code Module
Type
SMK8002 1mA
SMK8002 20mA
SMK8002 100mA
SMK8002 500mA
SMK8002 1A
SMK8002 2A
SMK8002 5A
Current
range
0.2-1 mA
4-20 mA
20-100 mA
100-500 mA
0.2-1 A
0.4-2 A
1-5 A
Max.
current
10 mA
100 mA
500 mA
2A
5A
6A
10 A
Input im-
pedance
102
Ω
5.11
Ω
1.0
Ω
0.1
Ω
0.1
Ω
20 mΩ
10 mΩ
Range equal rms value of a sinusoidal voltage, except
SMK8001 4V
p
.
Specifications are subject to change without notice (08.03.01)
1
S 180
Input Specifications
Input
Pins 5 V/A
Pins 6 5 A range
Pins 7 V/A
Latching
+ DC/AC phase
+ DC/AC phase
- DC/AC neutral
Interconnection of pins
8 & 9 latching at set level
Output Specifications
Output
Rated insulation voltage
Contact ratings
(AgCdO)
Resistive loads
AC 1
DC 1
or
Small inductive loads AC 15
DC 13
Mechanical life
Electrical life
AC 1
SPDT relay
250 VAC (rms)
(cont./elect.)
µ (micro gap)
10 A/250 VAC (2500 VA)
1 A/250 VDC (250 W)
10 A/25 VDC (250 W)
2.5 A/230 VAC
5 A/24 VDC
≥
30 x 10
6
operations
≥
2.5 x 10
5
operations
(at max. load)
≤
7200 operations/h
Supply Specifications
Power supply AC types
Rated operational voltage
Through pins 2 & 10 024
115
230
Voltage interruption
Dielectric voltage
Rated impulse withstand volt.
Overvoltage cat. III (IEC 60664)
(IEC 60038)
20-28 VAC, 45 to 65 Hz
90-130 VAC, 45 to 65 Hz
190-270 VAC, 45 to 65 Hz
≤
40 ms
None (supply/elect.)
4 kV (1.2/50 µs) (line/neutral),
no direct connection to
electronics
2.5 VA
Operating frequency
Dielectric strength
Dielectric voltage
≥
2 kVAC (rms) (cont./elect.)
Rated impulse withstand volt. 4 kV (1.2/50 µs) (cont./elect.)
(IEC 60664)
Rated operational power
General Specifications
Power ON delay
Reaction time
Indication for
Power supply ON
Output ON
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Weight
Approvals
CE Marking
≤
500 ms
τ
= 0.3 s, worst case reaction
time may be up to 5 x
τ
LED, green
LED, red
(IEC 60947-1)
IP 20 B (IEC 60529)
2 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
200 g
UL, CSA
Yes
Mode of Operation
S 180 is an AC/DC current/
voltage metering relay. The 7
current and 13 voltage ranges
are selected by means of dif-
ferent code modules. AC/DC
metering and delay on oper-
ate/delay on release timer
functions are selected by DIP-
switch behind the code mod-
ule. Inversion of the output is
possible by interconnecting
pins 9 and 11. Latching and
extension of hysteresis are
possible by interconnecting or
adding a resistor between pins
8 and 9.
Example 1 - Delay on
operate, max. level detection
The relay operates when the
measured value exceeds set
point for more than the set
time. The relay releases when
the measured value drops
below set point less hyster-
esis. If the relay is latched it
remains ON once it has been
activated. Example 1 is a so-
called lower min. level guard
when the relay is not latched.
Example 2 - Delay on re- le-
ase, max. level detection
The relay operates when the
measured value exceeds set
point. The relay releases when
the measured value drops
below set point less hyster-
esis for more than the set
time. Example 2 is a so called
min. level guard when the re-
lay is not latched.
Example 3 - Delay on
release, min. level detection
The relay releases when the
measured value exceeds set
point for more than the set
time. The relay operates when
the measured value drops
below set point less hyster-
esis. If the relay is latched it
remains ON once it has been
activated. Example 3 is a so-
called max. level guard when
the relay is not latched.
Example 4 - Delay on
release, min. level detection
The relay releases when the
measured value exceeds set
point. The relay operates
when the measured value
drops below set point less hy-
steresis for more than the set
time. Example 4 is a so- cal-
led max. level guard when the
relay is not latched.
Latching can be released by
opening the contact between
pins 8 and 9 or by interrupting
supply voltage.
2
Specifications are subject to change without notice (08.03.01)