These devices are intended for wave soldering or manual soldering.
they are not intended to be subject to surface mount processes under any circumstances.
The normal wave soldering process can be used with these devices where the device is subjected
to a maximum wave temperature of 260°C for a period of no more than 10 seconds. Within this
time and temperature range, the integrity of the device’s plastic body will not be compromised and
internal temperatures within the converter will not exceed 175°C. Care should be taken to control
manual soldering limits identical to that of wave soldering.
HPR0XXC
REV A (RoHS)
04/2006
Page 3
SAFE OPERATING AREA
600
500
LOAD CAPACITANCE vs INPUT RISE TIME
(5 Vout models)
60
LOAD CAPACITANCE vs INPUT RISE TIME
(15 Vout models)
50
Total Load Capacitance (uF)
Total Load Capacitance (uF)
400
40
300
30
SAFE OPERATING AREA
200
SAFE OPERATING AREA
20
100
10
0
0
5
10
15
20
25
30
35
Rise Time of Input Voltage (mS)
40
45
50
0
0
5
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
90
LOAD CAPACITANCE vs INPUT RISE TIME
(12 Vout models)
NOTES:
. When operated within the SAFE OPERATING AREA as defined
by the above curves, the output voltage of Hpr0xxC devices is
guaranteed to be within 95% of its steady-state value within 00
milliseconds after the input voltage has reached 95% of its steady-
state value.
2. For dual output models, total load capacitance is the sum of the
capacitances on the plus and minus outputs.
Total Load Capacitance (uF)
80
70
60
50
40
30
20
10
0
0
5
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
SAFE OPERATING AREA
ORDERING INFORMATION
HPR 10XX C
Device Family
HPR Indicates DC/DC Converter
Model Number
Selected from Table of Electrical Characteristics
RoHS Compliance
ABSOLUTE MAXIMUM RATINGS
Internal Power Dissipation.....................................................490mW
Short Circuit Duration......................................................Momentary
The information provided herein is believed to be reliable; however, C&D TeCHnOlOgieS assumes no responsibility for inaccuracies or omissions. C&D TeCHnOlOgieS assumes no responsibility for the use of
this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein
are implied or granted to any third party. C&D TeCHnOlOgieS does not authorize or warrant any C&D TeCHnOlOgieS product for use in life support devices/systems or in aircraft control applications.