Oven Controlled Crystal Oscillator
OX-501
Preliminary
Features
6-Pin SMD package
Fast Warm-up
TCXO Replacement for better short term stability
Typical Applications
Base Stations
Test Equipment
Femto Basestation
Military Communication Equipment
Frequency Range
Standard Frequencies
10 MHz – 100 MHz
10; 12.8; 16.384; 19.44; 20.00; 30.72; 38.88; 51.84 MHz
Frequency stabilities
1
[AT Cut Crystal-Standard-10 to 100 MHz]
Parameter
vs. operating temperature range
(Referenced to +25°C)
Min
-100
-250
-250
Typ
Max
+100
+250
+250
Units
ppb
ppb
ppb
Units
ppm
ppb
ppb
ppb
ppb
ppb
minutes
Operating temperature range
-20 … +70°C
-20 … +70°C
-40… +85°C
Condition
at time of shipment, nominal EFC
V
S
± 5% static
Load ± 5% static
after 30 days of operation
≤
60MHz;
>60MHz;
after 30 days of operation
after 30 days of operation
Parameter
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging
vs aging
vs. aging
/ day
/ year
/ year
Min
-0.5
-20
-20
-10
-300
-500
Typ
Max
+0.5
+20
+20
+10
+300
+500
2
Warm-up Time
to
±
200ppb of
fi
nal frequency (1 hour
reading) @ +25°C
htttp://www.vectron.com
Vectron International•267 LowellRoad,
Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
OX-501 page: 1/5
Options
5
Frequency stabilities
1
[SC Cut Crystal-Option-10 to 52 MHz]
Parameter
vs. operating temperature range
(Referenced to +25°C)
Min
-30
-50
Typ
Max
+30
+50
Units
ppb
ppb
Operating temperature range
-20 … +70°C
-40… +85°C
Options
5
Parameter
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging
vs aging
vs. aging
/ day
/ year
/ year
Min
-0.2
-10
-10
-5.0
-100
-500
Typ
Max
+0.2
+10
+10
+5.0
+100
+500
2
Units
ppm
ppb
ppb
ppb
ppb
ppb
minutes
Condition
at time of shipment, nominal EFC
V
S
± 5% static
Load ± 5% static
after 30 days of operation
≤
60MHz;
>60MHz;
after 30 days of operation
after 30 days of operation
Warm-up Time
to ± 100ppb of
fi
nal frequency (1 hour
reading) @ +25°C
Supply Voltage (Vs)
Parameter
Supply voltage [Standard]
Power consumption
Min
3.135
Typ
3.3
Max
3.465
2.2
0.7
Units
VDC
Watts
Watts
Condition
during warm-up
steady state @ +25°C
RF Output
Parameter
Signal [Standard]
Load
Signal Level (Vol)
Signal Level (Voh)
Duty cycle
Min
Typ
HCMOS
15
Max
Units
pF
Condition
0.4
2.4
45
55
VDC
VDC
%
with Vs=3.3V and 15pF load
with Vs=3.3V and 15pF load
@ (Voh-Vol)/2
htttp://www.vectron.com
Vectron International•267 LowellRoad,
Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
OX-501 page: 2/5
Frequency Tuning (EFC)
Parameter
Tuning Range
Tuning Range
±5.0
±1.0
Linearity
Tuning Slope
Control Voltage Range
0.0
1.4
10%
Positive
2.8
VDC
with Vs=3.3V
Min
Typ
Max
±12
±3
Units
ppm
ppm
Condition
with AT cut Crystal
with SC cut Crystal
Fixed OCXO; No adjust
Additional Parameters
Parameter
Phase Noise
3
Min
Typ
Max
-65
-95
-120
-140
-145
Units
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
g
1
10
100
1
10
Hz
Hz
Hz
kHz
kHz
Condition
@ 10 MHz
Weight
Processing & Packing
8.0
Handling & Processing Note
Absolute Maximum Ratings
Parameter
Supply voltage (Vs)
Output Load
Operable temperature range
Storage temperature range
-55
-55
Min
Typ
Max
5.5
50
+85
+125
Units
V
pF
°C
°C
Condition
with Vs=5.0VDC
Notes:
1 Contact factory for improved stabilities or additional product options. Not all options and codes are available at all
frequencies.
2 Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage,
frequency control voltage, load, temperature (25°C)
3 Phase noise degrades with increasing output frequency.
4 Subject to technical modification.
5 Contact factory for availability.
htttp://www.vectron.com
Vectron International•267 LowellRoad,
Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
OX-501 page: 3/5
Options
5
Enclosure
OX-501
Height “H”
9,9
Pin Length “L”
N.A
Pin Connections
1 Electronic Frequency Control Input (EFC)
2 Enable
3 Ground (Case)
4 RF Output
5 Uref
6 Supply Voltage Input
Standard Shipping Methode (For OX-501 Type)
A
X
B
P
*bei W
≤ 24
mm
nur untere Lochreihe
∗by
W
≤
24 mm only lower hole line
Lage im Gurt
Position in tape
Pin 1
Abwickelrichtung
Unwinding direction
K
Gurtunterseite
Tape buttom side
Gurtoberseite
Tape upper side
Production tolerance complying DIN IEC 286-3
Enclosure Type
Typ OX-501
Tape width W [mm]
N.A
Quantity per meter
N.A
Quantity per reel
N.A
Dimension P
N.A
htttp://www.vectron.com
Vectron International•267 LowellRoad,
Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
OX-501 page: 4/5
Recommanded Reflow Profile
Profile Feature
Average ramp-up rate (T
L
to T
p
)
Preheat
-Temperature Min T
Smin
-Temperature Min T
smax
-Time (min to max) t
S
Pb-Free Assembly/
Sn-Pb Assembly
3°C/second max.
150°C
200°C
60-180 seconds
3°C/second max
217°C
60-150 seconds
max 260°C
Profile Feature
Time 25°C to Peak Temperature
Time maintainted above
-Temperature (T
L
)
-Time (t
L
)
Pb-Free Assembly/
Sn-Pb Assembly
8 minutes max.
217°C
60-150 seconds
T
Smax
to T
L
-Ramp-up Rate
Time maintainted above
-Temperature (T
L
)
-Time (t
L
)
Peak Temperature (T
P
)
Time within 5°C of actual Peak
Temperature (t
P
)
Ramp-down Rate
20-40 seconds
6°C/ second max
Note: All temperatures refer to topside of the package, measured on the package body surface.
How to order this product:
Use this worksheet to forward the following information to your factory representative :
Model
OX-501
Height
0
-
-
Supply Voltage
Code
B
RF Output
Code
A
Temperatur
Range
E
-
-
Stability
108
Frequency
Control
0
-
-
Frequency
10MHz
Model Code:
501: SMD Version
Height:
0:
9,9 mm
Supply Voltage Code:
E:
3,3 V
RF Output Code:
A:
HCMOS
Frequency Control:
0:
No Tuning
1:
±5.0...±12 ppm
2:
±1.0...±3.0 ppm
Temperature Range:
E:
-40...+85°C
J:
-20...+70°C
P:
0...+50°C
Stability Code:
258:
508:
107:
257:
±25ppb
±50ppb
±100ppb
±250ppb
htttp://www.vectron.com
Vectron International•267 LowellRoad,
Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
OX-501 page: 5/5