Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8737 Multi-Conductor - Single-Pair Cable
For more Information
please call
1-800-Belden1
Description:
22 AWG stranded (7x30) tinned copper conductors, PVC insulation, twisted pair, tinned copper spiral
wrapped shield (85% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (mm)
1
22
7x30
TC - Tinned Copper 0.762
Insulation
Insulation Material:
Insulation Material
Dia. (mm)
PVC - Polyvinyl Chloride 1.524
Outer Shield
Outer Shield Material:
Type
Outer Shield Material Coverage (%)
85
Spiral Serve TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter:
4.572 mm
Pair
Pair Color Code Chart:
Number Color
1
Black & Red
Pair Lay Length & Direction:
Lay Length (mm) Twists/ft. (twist/m)
36.575856
27.331
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-20°C To +80°C
80°C (UL AWM Style 2095)
26.788 Kg/Km
88.964 N
43.180 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
CMG
CMG
Page 1 of 3
02-24-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8737 Multi-Conductor - Single-Pair Cable
AWM Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
UL Style 2095 (300 V 80°C)
Yes
Yes
Yes
04/01/2005
Yes
Yes
Yes
Yes
Flame Test
CSA Flame Test:
FT4
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
49
Nom. Inductance:
Inductance (µH/m)
0.55777
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
131.24
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/m)
229.67
Nominal Velocity of Propagation:
VP (%)
66
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
52.496
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
38.3877
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
3 Amps per conductor @ 25°C
Related Documents:
No related documents are available for this product
Put Ups and Colors:
Item #
8737 060U1000
8737 060U500
Putup
305 MT
152 MT
Ship Weight
9.072 KG
4.763 KG
Color
CHROME
CHROME
Notes
Item Desc
1 PR#22 PVC SHLD PVC
2 #22 PVC SHLD PVC
Page 2 of 3
02-24-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8737 Multi-Conductor - Single-Pair Cable
8737 0601000
8737 060500
Notes:
C = CRATE REEL PUT-UP.
305 MT
152 MT
9.072 KG
4.536 KG
CHROME
CHROME
C
1 PR#22 PVC SHLD PVC
1 PR#22 PVC SHLD PVC
Revision Number: 1
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 04-16-2008
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
02-24-2012