MCC
TM
Micro Commercial Components
omponents
20736 Marilla Street Chatsworth
!"#
$
% !"#
RS801M
THRU
RS807M
8 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
RS-6M
I
A
K
J
D
F
O
G
P
H
H
E
M
C
N
B
L
•
•
•
•
•
•
Features
Low Leakage
Low Forward Voltage
Any Mounting Position
Silver Plated Copper Leads
Surge Overload Rating Of 300 Amps
UL Recognized File # E165989
Maximum Ratings
•
•
Operating Junction Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
MCC
Catalog
Number
RS801M
RS802M
RS803M
RS804M
RS805M
RS806M
RS807M
Maximum
Recurrent
Peak Reverse
Voltage
RS801M
50V
RS802M
100V
RS803M
200V
RS804M
400V
RS805M
600V
RS806M
800V
RS807M
1000V
Device
Marking
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000v
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum Forward
Voltage Drop Per
Element
I
F(AV)
I
FSM
8.0A
300A
T
A
= 65°C
8.3ms, half sine
DIM
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
DIMENSIONS
INCHES
MIN
MAX
1.169
1.193
.697
.800
.669
.708
.197
.150
.165
.091
.106
.035
.043
.287
.303
.173
.189
.425
.441
.134
.150
.122
.134
.098
.114
.023
.031
.078
.094
.386
.402
MM
MIN
MAX
29.70
30.30
17.70
20.30
17.00
18.00
5.00
3.80
4.20
2.30
2.70
0.90
1.10
7.30
7.70
4.40
4.80
10.80
11.20
3.40
3.80
3.10
3.40
2.50
2.90
0.60
0.80
2.00
2.40
9.80
10.20
NOTE
V
F
1.1V
I
FM
= 4.0A;
T
J
= 25°C
Maximum DC
Reverse Current At
I
R
10µA
T
J
= 25°C
Rated DC Blocking
1mA
T
J
= 100°C
Voltage
*Pulse test: Pulse width 300
µsec,
Duty cycle 1%
Revision: 5
www.mccsemi.com
2004/04/14
RS801M thru RS807M
Figure 1
Typical Forward Characteristics
100
60
40
20
10
6
4
2
Amps
1
.6
.4
.2
.1
.06
.04
.02
.01
.2
.4
.6
.8
1.0
1.2
1.
25°
C
10
6
4
2
1
.6
.4
.2
µAmps
.1
.06
.04
.02
.01
.006
.00
4
.002
.001
20
40
T
J
=100°C
MCC
Micro Commercial Components
Figure 2
Typical Reverse Characteristics
TM
T
J
=25°C
60
80
Volts
100
120
140
Volts
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
12
Figure 4
Peak Forward Surge Current
300
250
200
150
10
8
Amps
6
4
Amps
100
50
2
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
25
50
75
100
125
150
0
1
2
4
6
8 10
Cycles
20
40
00
60 80 100
0
Average Forward Rectified Current - Amperes
versus
Case Temperature -
°C
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Revision: 5
www.mccsemi.com
2004/04/14