Metre - Handset - Sine - CORNING - Year - Cable type +
Fibre count + Fibre type
Temperature Range
Installation and assembly
Operation
Storage
-5 °C to 50 °C
-30 °C to 70 °C
-40 °C to 70 °C
Family Spec Sheet 0084_EMEA_BEN
Page 2 | Revision date 2012-12-14
Outdoor stranded loose tube cable
(minibundle) with glass yarn armouring
A-DQ(BN)2Y 12–288 LT, 2.25 mm tubes
Mechanical Characteristics Cable
Fibre
Count
Fibres
per
Tube
6
12
12
12
12
12
12
Number
of Active
Tubes
2-4
2-6
8
10
12
16 - 18
24
Weight
Nominal
Outer
Diameter
10.9 mm
10.9 mm
12.3 mm
13.8 mm
15.3 mm
15.5 mm
17.6 mm
Min. Bend
Radius
Installation
215 mm
215 mm
245 mm
275 mm
305 mm
305 mm
305 mm
Min. Bend
Radius
Operation
160 mm
160 mm
185 mm
205 mm
230 mm
230 mm
265 mm
Max.
Crush Resistance
tensile
strength for
installation
4000 N
4000 N
4000 N
4000 N
4000 N
4000 N
4000 N
2000 N/10cm
2000 N/10cm
2000 N/10cm
2000 N/10cm
2000 N/10cm
2000 N/10cm
2000 N/10cm
12 - 24
24 - 72
96
120
144
192 - 216
288
91 kg/km
91 kg/km
116 kg/km
145 kg/km
180 kg/km
177 kg/km
232 kg/km
* Fibre count per tube, colour coding of fibres and/or buffer tubes, hybrid construction, jacket colour and/or printings deviating from standard design have no influ-
ence whatsoever on mechanical and optical characteristics.
Chemical characteristics
RoHS
Free of hazardous substances according to RoHS 2002/95/
Contact Customer Service at 00800-2676-4641 (00800-CORNING1) for other options.
*Maximum delivery length per drum is 4000 metres +3/-2% for Multimode fibres and 6000 metres +3/-2% for Single-mode fibres.
*Please notice that in the hybrid cables construction (different fibre types) the Multimode fibres are in sequence from the higher to the lower performance fol-
lowed by the Single-mode fibres.
*For ordering information regarding non-standard design cables please contact our Customer Service Centre. (See bottom of page for contact information.)
Corning Cable Systems GmbH & Co. KG · Leipziger Strasse 121 · 10117 Berlin, Germany