Toggle Switches
Military
6.1
6.2
Introduction
Product Selection Guide
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V11-T6-2
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Military Purpose Toggles
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V11-T6-3
V11-T6-6
V11-T6-7
6.3
Illuminated AC Rated Toggles
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V11-T6-9
V11-T6-10
V11-T6-10
Illuminated AC Rated
6.4
General Purpose Toggles—AC Rated
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V11-T6-12
V11-T6-16
V11-T6-16
6.5
General Purpose Toggles—AC/DC Rated
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V11-T6-20
V11-T6-21
V11-T6-21
6.6
General Purpose AC/DC Rated
X Series Toggles
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V11-T6-24
V11-T6-25
V11-T6-25
V11-T6-26
6.7
Heavy Duty Hesitation Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V11-T6-27
V11-T6-29
V11-T6-29
6.8
X Series Toggles
Accessories
Mounting Hardware
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Decorator Facenuts
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Panel Seal
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacement Terminal Screws
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Indicating Plates
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V11-T6-31
V11-T6-33
V11-T6-33
V11-T6-33
V11-T6-34
6.9
Technical Data
Circuit Diagrams
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V11-T6-35
Volume 11—Vehicle and Commercial Controls
CA08100013E—October 2011 www.eaton.com
V11-T6-1
6.1
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
V11-T6-2
Product Selection
Circuit Diagram
Product Description
Product Selection
Circuit Diagram
Product Description
Toggle Switches
Toggle Switches
Introduction
Contents
Description
Military Purpose Toggles . . . . . . . . . . . . . . . . . . . .
Illuminated AC Rated Toggles . . . . . . . . . . . . . . . .
General Purpose Toggles—AC Rated. . . . . . . . . . .
General Purpose Toggles—AC/DC Rated. . . . . . . .
X Series Toggles . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy Duty Hesitation Switches . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V11-T6-3
V11-T6-9
V11-T6-11
V11-T6-20
V11-T6-24
V11-T6-27
V11-T6-31
V11-T6-35
Product Selection Guide
Toggle Switches
Military Purpose Toggles
Illuminated AC Rated Switches
General Purpose Toggles—
AC Rated
Page V11-T6-3
Page V11-T6-35
Eaton’s military purpose switches
are designed to meet the
requirements of MIL-S-83731
Page V11-T6-9
—
These illuminated switches
are available only in single-pole
circuitry. A two-pole base is utilized
with single-pole housing the lamp.
Page V11-T6-20
Page V11-T6-35
These AC rated toggle switches offer
the widest selection of features and the
design flexibility to meet a variety of
applications.
General Purpose Toggles—
AC/DC Rated
X Series Toggles
Heavy Duty Hesitation Switches
Page V11-T6-20
Page V11-T6-35
This line of switches employs a quick-
make/quick-break contact mechanism.
These switches are especially suited for
use in small motor applications.
Page V11-T6-24
—
Eaton’s new, competitively priced, AC
rated X Series toggles offer a standard
high rating for both single- and two-pole
applications.
Page V11-T6-27
Page V11-T6-35
The most common application
for this switch is to help prevent
motor damage resulting from
the high current generation by
counter EMF of the armature at the
time of reversing.
Volume 11—Vehicle and Commercial Controls
CA08100013E—October 2011 www.eaton.com
Toggle Switches
Military Purpose Toggles
6.2
Page
V11-T6-6
V11-T6-7
Military Purpose Toggles
Contents
Description
Military Purpose Toggles
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
6
6
6
6
6
6
6
6
6
Product Description
Eaton’s military purpose
switches are designed to
meet the requirements of
MIL-S-83731. Sealed
Switches have a silicone
rubber lever seal assembled
between the lever and the
bushing to resist the entrance
of contaminants such as
dust, sand or water into the
contact structure.
The switch mechanisms are
completely enclosed to resist
the entrance of contaminants
into the switch. All metal
parts are plated to resist
corrosion. The heavy duty
switches are offered in both
standard toggle lever and
lever lock versions. Circuit
designations are stamped on
the side of each switch.
Standards and
Certifications
●
6
6
6
6
6
6
6
6
Military
Solder Lug Terminals
MIL-S-83731
Product Selection
AC/DC Rated (Medium Duty) MIL-S-83731
Circuit with Toggle in …
UP
Position
Current
Ratings
Poles
and
Throw
CENTER
Position
DOWN
Position
(Keyway)
Base
Circuit
See
Page V11-T6-35
6
6
6
6
6
6
6
6
6
6
6
6
V11-T6-3
Dimension
“A”
Inches (mm)
Dimension
“B”
Inches (mm)
MIL-S-83731
with Sealed
Lever
Catalog
Number
Single-Pole
See
A
below
See
A
below
Two-Pole
See
B
below
See
C
below
2PST
ON
ON
OFF
ON
ON
NONE
NONE
NONE
NONE
NONE
OFF
MOM. OFF
MOM. ON
ON
MOM. ON
C
—
0.906 (23.01)
MS25100-22
MS25100-29
MS25100-30
MS25100-23
MS25100-26
8262K22
8262K29
8262K30
8262K23
8262K26
1PST
ON
ON
OFF
ON
ON
NONE
NONE
NONE
NONE
NONE
OFF
MOM. OFF
MOM. ON
ON
MOM. ON
A
—
0.906 (23.01)
MS25098-22
MS25098-29
MS25098-30
MS25098-23
MS25098-26
8261K22
8261K29
8261K30
8261K23
8261K26
1PDT
B
0.937 (23.80)
—
2PDT
D
0.937 (23.80)
—
Current Ratings
Current Capacity in Amperes
per Pole = 125 Vac, 60 Hz
Part Number
A
AII MS25098
B
MS25100-22, 29, 30
C
MS25100-23, 26
Resistive
Load
3.0
3.0
1.0
Inductive
Load
1.5
1.5
1.0
Volume 11—Vehicle and Commercial Controls
CA08100013E—October 2011 www.eaton.com
6.2
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
V11-T6-4
Toggle Switches
Military Purpose Toggles
AC Rated (Heavy Duty) MIL-S-83731 with Lever Seal
Circuit with Toggle in …
UP
Position
Current
Ratings
Poles
and
Throw
CENTER
Position
DOWN
Position
(Keyway)
Base
Circuit
See Page
V11-T6-35
Bushing
Length
“A”
Inches (mm)
Lever
Length
“B”
Inches (mm)
Screw Terminals
with Sealed Lever
MS Part
Number
Catalog
Number
Single-Pole
See
A
below
See
B
below
1PST
ON
ON
ON
ON
NONE
OFF
ON
ON
ON
MOM. ON
ON
NONE
OFF
NONE
MOM. OFF
OFF
NONE
OFF
NONE
NONE
OFF
OFF
OFF
NONE
MOM. OFF
NONE
MOM. ON
MOM. ON
ON
ON
MOM. ON
MOM. ON
MOM. ON
A
0.468 (11.89)
0.687 (17.45)
MS35058-22
MS35058-24
MS35058-29
MS35058-25
MS35058-28
MS35058-30
MS35058-21
MS35058-23
MS35058-26
MS35058-27
MS35058-31
8801K22
8801K23
8813K17
8813K18
8811K18
8811K17
8800K16
8810K15
8804K13
8812K14
8809K16
See
A
below
See
B
below
Two-Pole
See
C
below
See
D
below
1PDT
B
0.468 (11.89)
0.687 (17.45)
2PST
ON
ON
ON
ON
NONE
OFF
ON
ON
ON
MOM. ON
ON
ON
1
ON
1
MOM. ON
1
ON
1
ON
1
MOM. ON
1
NONE
OFF
NONE
MOM. OFF
OFF
NONE
OFF
NONE
NONE
OFF
OFF
ON
2
ON
2
ON
2
ON
3
ON
3
ON
3
OFF
NONE
MOM. OFF
NONE
MOM. ON
MOM. ON
ON
ON
MOM. ON
MOM. ON
MOM. ON
ON
4
MOM. ON
4
MOM. ON
4
ON
4
MOM. ON
4
MOM. ON
4
C
0.468 (11.89)
0.687 (17.45)
MS35059-22
MS35059-24
MS35059-29
MS35059-25
MS35059-28
MS35059-30
MS35059-21
MS35059-23
MS35059-26
MS35059-27
MS35059-31
MS25201-4
MS25201-5
MS25201-6
MS25201-7
MS25201-8
MS25201-9
8822K20
8822K21
8828K13
8828K12
8826K14
8826K15
8820K16
8824K14
8830K13
8834K5
8832K6
8860K4
8860K5
8860K6
8860K7
5
8860K8
5
8860K9
5
See
C
below
See
D
below
See
E
below
2PDT
D
0.468 (11.89)
0.687 (17.45)
1P3T
in a
2P base
See
Page V11-T6-35
0.468 (11.89)
0.687 (17.45)
Four-Pole
See
F
below
See
G
below
See
F
below
See
G
below
4PST
ON
ON
ON
NONE
OFF
ON
ON
ON
MOM. ON
ON
NONE
OFF
MOM. OFF
OFF
NONE
OFF
NONE
NONE
OFF
OFF
OFF
NONE
NONE
MOM. ON
MOM. ON
ON
ON
MOM. ON
MOM. ON
MOM. ON
E
0.468 (11.89)
0.687 (17.45)
—
MS25068-24
MS25068-25
MS25068-28
—
MS25068-21
MS25068-23
MS25068-26
MS25068-27
MS25068-31
7660K12
7660K13
7668K7
7666K9
7666K6
7662K7
7664K5
7674K5
7672K5
7670K6
4PDT
F
0.468 (11.89)
0.687 (17.45)
Current Ratings
Current Capacity in Amperes per Pole
28 Vdc
Switch
A
B
C
D
E
F
G
MS35058
MS35058
MS35059
MS35059
MS25201
MS25068
MS25068
Type of
Operation
Maintained
Momentary
Maintained
Momentary
ON-ON-ON
Maintained
Momentary
Lamp
Load
7
5
7
5
5
5
4
Resistive
Load
25
20
20
18
18
20
18
Inductive
Load
15
10
15
10
10
12
10
115 Vac, 60 Hz
Lamp
Load
—
—
—
—
2
—
—
Resistive
Load
10
10
20
11
11
—
—
Inductive
Load
10
7
—
—
8
—
—
115 Vac, 400 Hz
Lamp
Load
3
—
4
—
2
4
2
Resistive
Load
10
—
20
—
11
20
11
Inductive
Load
10
—
15
—
8
15
5
Notes
1
Across terminals 2-3 and 5-6.
2
Across terminals 1-2 and 5-6.
3
Across terminals 2-3 and 4-5.
4
Across terminals 1-2 and 4-5.
5
For “INDEPENDENT ON-ON-ON” circuit arrangement, see
Page V11-T6-35.
Volume 11—Vehicle and Commercial Controls
CA08100013E—October 2011 www.eaton.com
Toggle Switches
Military Purpose Toggles
6.2
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
AC Rated (Heavy Duty) MIL-S-83731 Lever Lock with Lever Seal
Circuit with Toggle in …
UP
Position
Current
Ratings
Poles
and
Throw
CENTER
Position
DOWN
Position
Base
Circuit
See
(Keyway) Page V11-T6-35
Lever
Lock
Bushing
Style
1
Screw Terminals
with Sealed Lever
Bushing
Length “A”
Inches (mm)
Lever Lock
Length “B”
Inches (mm)
MS Part
Number
Catalog
Number
Single-Pole
See
A
below
See
A
below
Two-Pole
See
B
below
Four-Pole
See
C
below
4PDT
ON
NONE
ON
F
4
0.562 (14.27)
1.000 (25.40)
MS25127-E3
8859K44
2PDT
ON
ON
ON
OFF
OFF
NONE
ON
ON
ON
C
1
2
4
0.562 (14.27)
1.000 (25.40)
MS25126-A1
MS25126-B1
MS25126-E3
8858K39
8858K40
8858K44
1PST
ON
ON
ON
ON
ON
ON
NONE
NONE
OFF
OFF
NONE
NONE
OFF
OFF
NONE
ON
ON
ON
A
3
4
5
2
3
4
0.562 (14.27)
1.000 (25.40)
MS25125-C2
MS25125-E2
MS25125-J4
MS25125-B1
MS25125-C3
MS25125-E3
8857K47
8857K48
8857K49
8857K40
8857K45
8857K44
1PDT
B
0.562 (14.27)
1.000 (25.40)
Indicates direction against which lever is locked.
Current Ratings
Current Capacity in Amperes per Pole
28 Vdc
Switch
A
MS25125
B
MS25126
C
MS25127
1
115 Vac, 60 Hz
Lamp
Load
—
—
—
Resistive
Load
—
—
—
Inductive
Load
—
—
—
115 Vac, 400 Hz
Lamp
Load
3
4
4
Resistive
Load
10
20
20
Inductive
Load
10
15
15
Type of
Operation
Maintained
Maintained
Maintained
Lamp
Load
5
7
5
Resistive
Load
20
20
20
Inductive
Load
15
15
15
Note
See illustrations below for lever lock bushing styles.
Lever Lock Bushing Styles
Style 1
Style 2
Style 3
Style 4
Style 5
Locked in Three
Positions
Locked in
Center Positions
Locked in
Keyway Side
Locked out of
Center Position
Locked in Center
and Side Opposite
Keyway
These illustrations are for pictoral representation only—keyway on right-hand side.
Volume 11—Vehicle and Commercial Controls
CA08100013E—October 2011 www.eaton.com
V11-T6-5