RoHS
Compliant
Broadband CATV, 10dB Coupler
5-1000 MHz
Features
•
•
•
•
•
•
Surface mount
Typical coupling +10dB
260°C reflow compatible
RoHS* compliant
RoHS version of MACPES0034.
Available on tape and reel, reel quantity 2000
MACPCT0039
V1P
Schematic
Description
M/A-COM’s MACPCT0039 is a 10dB broadband
Coupler in a low cost, surface mount package. It of-
fers low loss, good isolation, good input/output
matching and exceptional coupling repeatability.
Ideally suited for high volume CATV/Broadband
applications.
Pin Configuration
Pin No.
1
2
3
4
5
Case Style: SM-138
Function
Input
Ground
Coupled
Isolated (external 75 Ohms termination)
Output
Ordering Information
Part Number
MACPCT0039TR
MACP-007982-CT39TB
Package
2000 piece reel
Customer Test Board
Dimensions in inches [mm] Tolerance: .xx ± .02, .xxx ± .010
Note: Reference Application Note
M513
for reel size information.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
ADVANCED:
Data Sheets contain information regarding a product M/A-COM Technology Solutions
•
North America
Tel: 800.366.2266 •
Europe
Tel: +353.21.244.6400
is considering for development. Performance is based on target specifications, simulated results,
•
India
Tel: +91.80.4155721
•
China
Tel: +86.21.2407.1588
and/or prototype measurements. Commitment to develop is not guaranteed.
Visit www.macomtech.com for additional data sheets and product information.
PRELIMINARY:
Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.
RoHS
Compliant
Broadband CATV, 10dB Coupler
5-1000 MHz
MACPCT0039
V1P
Electrical Specifications: T
A
= 25°C, Z
0
= 75Ω
1
Parameter
Coupling
Coupling Flatness
Main Line Loss
Test Conditions
5 - 870 MHz
870 - 1000 MHz
5 - 1000 MHz
5—500 MHz
500 - 870 MHz
870 - 1000 MHz
5 - 1000 MHz
5 - 1000 MHz
5 - 1000MHz
5 - 500 MHz
500 - 1000 MHz
Units
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Min
-
-
-
-
-
-
18
18
18
25
20
Typ
10
10
-
0.9
1.2
1.6
20
20
20
30
23
Max
± 0.5
±0.9
1.0
1.3
1.5
1.8
-
-
-
-
Input Return Loss
Output Return Loss
Coupling Return Loss
Isolation
Absolute Maximum Ratings
1,2
Parameter
Max Input Power
DC current
Operating Temperature
Storage Temperature
Recommended PCB Configuration
Absolute Maximum
250mW
30mA
-40°C to +85°C
-55°C to +100°C
1. Exceeding any one or combination of these limits may cause
permanent damage to this device.
2. M/A-COM does not recommend sustained operation near
these survivability limits.
2
ADVANCED:
Data Sheets contain information regarding a product M/A-COM Technology Solutions
•
North America
Tel: 800.366.2266 •
Europe
Tel: +353.21.244.6400
is considering for development. Performance is based on target specifications, simulated results,
•
India
Tel: +91.80.4155721
•
China
Tel: +86.21.2407.1588
and/or prototype measurements. Commitment to develop is not guaranteed.
Visit www.macomtech.com for additional data sheets and product information.
PRELIMINARY:
Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.
RoHS
Compliant
Broadband CATV, 10dB Coupler
5-1000 MHz
Typical Performance Curves T
A
= 25°C, Z
0
= 75Ω
Coupling
-5
-6
-7
-8
-9
MACPCT0039
V1P
Main Line Loss
0.0
-0.2
-0.4
-0.6
-0.8
dB
dB
5
204
403
602
801
1000
-10
-11
-12
-13
-14
-15
-1.0
-1.2
-1.4
-1.6
-1.8
-2.0
5
204
403
602
801
1000
Frequency (MHz)
Frequency (MHz)
Isolation
0
-5
-10
Input Return Loss
0
-5
-10
dB
dB
-15
-20
-25
-30
-35
5
204
403
602
801
1000
-15
-20
-25
-30
-35
5
204
403
602
801
1000
Frequency (MHz)
Frequency (MHz)
Output Return Loss
0
-5
-10
Coupling Return Loss
0
-5
-10
-15
dB
-20
-25
-30
-35
dB
-15
-20
-25
-30
-40
-45
5
204
403
602
801
1000
-35
5
204
403
602
801
1000
Frequency (MHz)
Frequency (MHz)
3
ADVANCED:
Data Sheets contain information regarding a product M/A-COM Technology Solutions
•
North America
Tel: 800.366.2266 •
Europe
Tel: +353.21.244.6400
is considering for development. Performance is based on target specifications, simulated results,
•
India
Tel: +91.80.4155721
•
China
Tel: +86.21.2407.1588
and/or prototype measurements. Commitment to develop is not guaranteed.
Visit www.macomtech.com for additional data sheets and product information.
PRELIMINARY:
Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.