760146563 | Z-006-DN-5K-F06BK/20G/D
LazrSPEED® Indoor/Outdoor Low Smoke Zero Halogen Single Jacket All-
Dielectric Arid-Core Drop Cable
Product Classification
Portfolio
Product Type
Regional Availability
CommScope®
Fiber drop cable
Asia | Australia/New Zealand | EMEA | Latin America | North America
Standards And Qualifications
EN50575 CPR Cable EuroClass
Cable Qualification Standards
Dca | s2 | d1 | a1
ANSI/ICEA S-110-717 | EN 187105 | Telcordia GR-409
Representative Image
General Specifications
Cable Type
Construction Type
Subunit Type
Riser rated low smoke
Non-armored
Gel-filled
Construction Materials
page 1 of 3
March 26, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 9, 2019
760146563 | Z-006-DN-5K-F06BK/20G/D
Fiber Type Solution
Jacket Material
Total Fiber Count
Fiber Type
Fiber Type, quantity
Fibers per Subunit, quantity
Jacket Color
Jacket UV Resistance
OM4, LazrSPEED® 550
Low Smoke Zero Halogen (LSZH)
6
OM4, LazrSPEED® 550
6
6
Black
UV stabilized
Dimensions
Buffer Tube/Subunit Diameter
Cable Weight
Diameter Over Jacket
Subunit, quantity
2.00 mm | 0.08 in
30.0 lb/kft | 44.0 kg/km
6.10 mm | 0.24 in
1
Physical Specifications
Minimum Bend Radius, loaded
Minimum Bend Radius, unloaded
9.1 cm | 3.6 in
6.1 cm | 2.4 in
Tensile Load, long term, maximum
400 N | 90 lbf
Tensile Load, short term, maximum
1334 N | 300 lbf
Vertical Rise, maximum
927.0 m | 3041.3 ft
Flame Test Specifications
Flame Test Listing
Flame Test Method
NEC OFNR-LS (ETL) and c(ETL)
IEC 60332-3 | IEC 60754-2 | IEC 61034-2 | IEEE 383 | UL 1666 | UL 1685
Environmental Specifications
Environmental Space
Installation Temperature
Operating Temperature
Storage Temperature
Aerial, lashed | Buried | Low Smoke Zero Halogen (LSZH) | Riser
-20 °C to +60 °C (-4 °F to +140 °F)
-20 °C to +70 °C (-4 °F to +158 °F)
-40 °C to +75 °C (-40 °F to +167 °F)
Mechanical Test Specifications
Compression
Compression Test Method
Flex
Flex Test Method
Impact
10 N/mm | 57 lb/in
FOTP-41 | IEC 60794-1 E3
35 cycles
FOTP-104 | IEC 60794-1 E6
1.63 ft lb | 2.21 N-m
page 2 of 3
March 26, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 9, 2019
760146563 | Z-006-DN-5K-F06BK/20G/D
Impact Test Method
Strain
Strain Test Method
Twist
Twist Test Method
Water Penentration
Water Penentration Test Method
FOTP-25 | IEC 60794-1 E4
See long and short term tensile loads
FOTP-33 | IEC 60794-1 E1
10 cycles
FOTP-85 | IEC 60794-1 E7
24 h
FOTP-82 | IEC 60794-1 F5
Environmental Test Specifications
Cable Freeze
Cable Freeze Test Method
Drip
Drip Test Method
Heat Age Test Method
Low High Bend
Low High Bend Test Method
Temperature Cycle
Temperature Cycle Test Method
-2 °C | 28 °F
FOTP-98 | IEC 60794-1 F15
70 °C | 158 °F
FOTP-81 | IEC 60794-1 E14
IEC 60794-1 F9
-20 °C to +60 °C (-4 °F to +140 °F)
FOTP-37 | IEC 60794-1 E11
-20 °C to +70 °C (-4 °F to +158 °F)
FOTP-3 | IEC 60794-1 F1
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
CENELEC
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
EN 50575 compliant, Declaration of Performance (DoP) available
Included Products
CS -5K-LT (Product Component—not orderable)
—
LazrSPEED ® 550 OM4 Bend-Insensitive Multimode Fiber
CS-5K-
Component—
LazrSPEED®
Bend-
* Footnotes
Operating Temperature
Specification applicable to non-terminated bulk fiber cable
page 3 of 3
March 26, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 9, 2019