A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet – MK06 Reed Sensors
www.standexmeder.com
MK06 Series
Reed Sensors
Features: High Power Switches, Various Case Sizes and Operate Sensitivities Available
Applications: On/Off Control Switch, Position Detection, Switching Element & Others
Markets: Appliance, Telecommunication, Security, Medical, Industry & Others
Part Description:
MK 06-0-X
Size
Magnetic Sensitivity
B, C, D, E, H, I, K
Switch Model
66
10
200
0.5
1.0
150
0.25
0.7
0.05
10
10
0.3
87
10
200
0.4
0.5
150
0.23
0.6
0.05
10
9
0.2
90
10
175
0.5
1.0
150
0.2
0.7
1.5
10
9
1.5
4, 5, 6, 7, 8, 10
Customer Options
Contact Data
Rated Power (max.)
Any DC combination of V&A not to exceed their individual max.’s
Unit
W
V
A
A
mOhm
kVDC
ms
ms
Ohm
pF
Switching Voltage (max.)
DC or peak AC
Switching Current (max.)
DC or peak AC
Carry Current (max.)
DC or peak AC
Contact Resistance (max.)
@ 0.5V & 50mA
Breakdown Voltage (min.)
According to EN60255-5
Operating Time (max.)
Incl. Bounce; Measured with w/ Nominal Voltage
Release Time (max.)
Measured with no Coil Excitation
Insulation Resistance (typ.)
Rh<45%, 100V Test Voltage
Capacitance (typ.)
@ 10kHz across open Switch
USA:
Europe:
Asia:
+1.866.782.6339
+49.7731.8399.0
+86.21.37820625
│
salesusa@standexmeder.com
│ info@standexmeder.com
│ salesasia@standexmeder.com
Version 01
27.01.2015
Modifications in the sense of technical progress are reserved.
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet – MK06 Reed Sensors
Housing and Lead Specifications
Housing Material
Case Color
Sealing Compound
Lead Design
PBT Glass Fibre Reinforced
Blue
Epoxy Resin
THT
www.standexmeder.com
MK06 Reed Sensor
Environmental Data
Shock Resistance (max.)
1/2 sine wave duration 11ms
Unit
30
20
-20 to 85
-35 to 85
260
g
g
°C
°C
°C
Vibration Resistance (max.)
Operating Temperature
Storage Temperature
Soldering Temperature (max.)
5 sec. max.
Life Test Data
*Load increase reduces life expectancy of Reed Switches
Handling & Assembly Instructions
Use proper lead clamping or heat sinking techniques to
prevent mechanical and/or heat stress during, soldering, and
welding
Mechanical shock as the result of dropping the reed sensor
may cause immediate or post-installation failure
Glossary Magnetic Sensitivity
Glossary Contact Form
Form A
Form B
Form C
NO = Normally Open Contacts
SPST = Single Pole Single Throw
NC = Normally Closed Contacts
SPST = Single Pole Single Throw
Changeover
SPDT = Single Pole Double Throw
AT Range
05 – 10
10 – 15
15 – 20
20 – 25
25 – 30
30 – 35
35 - 40
Sensitivity
(Form A)
A
B
C
D
E
F
G
Sensitivity
(Form C)
H
I
K
USA:
Europe:
Asia:
+1.866.782.6339
+49.7731.8399.0
+86.21.37820625
│
salesusa@standexmeder.com
│ info@standexmeder.com
│ salesasia@standexmeder.com
Version 01
27.01.2015
Modifications in the sense of technical progress are reserved.
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet – MK06 Reed Sensors
Dimensions
www.standexmeder.com
USA:
Europe:
Asia:
+1.866.782.6339
+49.7731.8399.0
+86.21.37820625
│
salesusa@standexmeder.com
│ info@standexmeder.com
│ salesasia@standexmeder.com
Version 01