SY Cable
Specifications:
Conductor
Insulation
Screen
Inner jacket
Outer sheath
Nominal Voltage
Test voltage
Temperature range (static)
Temperature range (flexing)
Bending radius
Flame Retardant
Core colour
:
:
:
:
:
:
:
:
:
:
:
:
Bare copper, fine wire, IEC 228 class 5 VDE 0295
PVC compound
Galvanized Steel wire screening
PVC compound
PVC compound
300 / 500 V
4,000 V
-30 +70°C
-5 +70°C
15 × D
IEC 332-1
Cores black with continuous white figure imprint earth conductor green / yellow
Specification Table
Description
Cable, CTRL, SY, 4 Core, 0.75mm, 50m
4 × 0.75
Cable, CTRL, SY, 4 Core, 0.75mm, 100m
Cable, CTRL, SY, 4 Core, 1mm, 50m
4×1
Cable, CTRL, SY, 4 Core, 1mm, 100m
Cable, CTRL, SY, 4 Core, 1.5mm, 50m
4 × 1.5
Cable, CTRL, SY, 4 Core, 1.5mm, 100m
Cable, CTRL, SY, 4 Core, 2.5mm, 50m
Cable, CTRL, SY, 4 Core, 4mm, 50m
Cable, CTRL, SY, 5 Core, 0.75mm, 50m
Cable, CTRL, SY, 5 Core, 1mm, 50m
Cable, CTRL, SY, 5 Core, 2.5mm, 50m
Cable, CTRL, SY, 5 Core, 4mm, 50m
4 × 2.5
4×4
5 × 0.75
5×1
5 × 2.5
5×4
10.8
12.7
8.9
9.2
11.7
14.1
9.3
10979400-100M
10998700-50M
10994200-50M
10988500-50M
10997800-50M
10997900-50M
10999000-50M
8.7
10998400-100M
10979400-50M
8.1
10985000-100M
10998400-50M
Number of
Cores x Cores Section
(mm
2
)
Outer Diameter
(mm)
Part Number
10985000-50M
Important Notice :
This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of
it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces
all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use
made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted.
Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising)
is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Pro-POWER is the registered trademark of the Group. © Premier Farnell plc 2011.
www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
17/05/11 V1.1