Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9269 Coax - 93 Ohms
For more Information
please call
1-800-Belden1
Description:
22 AWG solid .025" bare copper-covered steel conductor, semi-solid polyethylene insulation, bare copper
braid shield (95% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material
1
22
Solid
Dia. (mm)
BCCS - Bare Copper Covered Steel 0.635
Insulation
Insulation Material:
Insulation Material
Dia. (mm)
Semi-Solid PE - Semi-Solid Polyethylene 3.7084
Outer Shield
Outer Shield Material:
Type Outer Shield Material Coverage (%)
Braid BC - Bare Copper
95
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cabling
Overall Nominal Diameter:
6.071 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-40°C To +80°C
60°C (UL AWM Style 1478)
50.599 Kg/Km
373.649 N
63.500 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
AWM Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
CM, CL2
CM
UL Style 1478 (30 V 60°C)
Yes
Yes
Yes
01/01/2004
Yes
Page 1 of 3
05-10-2011
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9269 Coax - 93 Ohms
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
PMSHA Specification:
Customer Part Number Reference Specification:
RG Type:
Yes
Yes
Yes
SC-182/3
IBM P/N 323921
62A/U
Flame Test
UL Flame Test:
UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N):
Plenum Number:
No
89269, 87269, 82269
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
93
Nom. Inductance:
Inductance (µH/m)
0.380596
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
44.2935
Nominal Velocity of Propagation:
VP (%)
84
Nominal Delay:
Delay (ns/m)
3.97001
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
135.177
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
9.5149
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
1
10.00
50.00
100.00
200.00
400.00
700.00
900.00
1000.00
0.9843
2.95
6.23
8.86
12.47
17.39
23.95
26.90
28.54
Max. Operating Voltage - UL:
Voltage
300 V RMS (CM)
150 V RMS (CL2)
30 V RMS (UL AWM Style 1478)
Max. Operating Voltage - Non-UL:
Page 2 of 3
05-10-2011
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9269 Coax - 93 Ohms
Voltage
750 V RMS
Related Documents:
No related documents are available for this product
Put Ups and Colors:
Item #
9269 A8RU1000
9269 003U1000
9269 010U1000
9269 010U500
9269 0101000
9269 0101640
9269 0102000
9269 0103280
9269 010500
9269 0105000
9269 060U1000
Notes:
C = CRATE REEL PUT-UP.
Putup
305 MT
305 MT
305 MT
152 MT
305 MT
500 MT
610 MT
1,000 MT
152 MT
1,524 MT
305 MT
Ship Weight
16.329 KG
16.329 KG
16.329 KG
8.391 KG
17.237 KG
27.524 KG
34.473 KG
55.048 KG
7.711 KG
83.915 KG
16.329 KG
Color
BEIGE, SNOW
ORANGE
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
CHROME
C
C
C
C
C
Notes
Item Desc
RG-62A/U TYPE COAX
RG-62A/U TYPE COAX
RG-62A/U TYPE COAX
RG-62A/U TYPE COAX 306 2.09
RG-62A/U TYPE COAX
RG-62A/U TYPE COAX
RG-62A/U TYPE COAX
RG-62A/U TYPE COAX
RG-62A/U TYPE COAX
RG-62A/U TYPE COAX
RG-62A/U TYPE COAX
Revision Number: 1
© 2011 Belden, Inc
All Rights Reserved.
Revision Date: 03-07-2008
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
05-10-2011