Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8418 Multi-Conductor - Microphone/Musical Instrument Cable
For more Information
please call
1-800-Belden1
Description:
Mic, 20 AWG stranded (26x34) high-conductivity TC conductors, rubber insulation, cotton wrap, rayon
braid, TC braid shield (85% coverage), EPDM rubber jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
8
20
26x34
Dia. (in.)
High Conductivity TC - Tinned Copper .037
Insulation
Insulation Material:
Insulation Material
Wall Thickness (in.) Dia. (in.)
.083
EPDM - Ethylene Propylene Diene Monomer Rubber .023
Outer Shield
Outer Shield Material:
Type Outer Shield Material Coverage (%)
Braid TC - Tinned Copper
85
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
EPDM - Ethylene Propylene Diene Monomer Rubber .037
Overall Cabling
Overall Cabling Lay Length & Direction:
Length (in.) Twists (ft.)
2.92
4.1
Overall Cabling Color Code Chart:
Number Color
1
2
3
4
5
6
7
8
Blue
Orange
Black
White
Brown
Green
Red
Yellow
Overall Cabling Separator Material:
Overall Nominal Diameter:
Rayon Braid, Cotton Serve
0.381 in.
Mechanical Characteristics (Overall)
Operating Temperature Range:
Non-UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
-50°C To +90°C
60°C
100 lbs/1000 ft.
116 lbs.
Page 1 of 3
05-10-2011
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8418 Multi-Conductor - Microphone/Musical Instrument Cable
Min. Bend Radius (Install)/Minor Axis:
3.800 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
52
Nom. Inductance:
Inductance (µH/ft)
0.18
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
30
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
55
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
10.2
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
2.4
Max. Operating Voltage - Non-UL:
Voltage
600 V RMS
Max. Recommended Current:
Current
2.8 Amps per conductor @ 25°C
Related Documents:
No related documents are available for this product
Put Ups and Colors:
Item #
8418 010100
8418 010250
Notes:
C = CRATE REEL PUT-UP.
Putup
100 FT
250 FT
Ship Weight
11.000 LB
25.000 LB
Color
BLACK
BLACK
C
Notes
Item Desc
8 #20 EPDM BRD EPDM
8 #20 EPDM BRD EPDM
Page 2 of 3
05-10-2011
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8418 Multi-Conductor - Microphone/Musical Instrument Cable
Revision Number: 1
© 2011 Belden, Inc
All Rights Reserved.
Revision Date: 05-14-2007
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
05-10-2011