Stresses exceeding maximum ratings may damage the device. Maximum ratings are stress ratings only. Functional
operation above the recommended operating conditions is not implied. Extended exposure to stresses above the
recommended operating conditions may affect device reliability.
Electrical Characteristics
Parameter
Forward voltage
T
j
= 25°C
Test Conditions
I
F
= 200mA
Symbol
V
F
Maximum
1.5
Unit
V
http://www.element14.com
http://www.farnell.com
http://www.newark.com
Page <1>
06/04/11 V1.1
Zener Diode
1N746A-1N759A
Specification Table
V
Znom1)
Description
V
Zener Diode
Zener Diode
Zener Diode
Zener Diode
Zener Diode
Zener Diode
Zener Diode
Zener Diode
Zener Diode
Zener Diode
Zener Diode
Zener Diode
Zener Diode
Zener Diode
1)
I
ZT
mA
for
Z
ZT
Ω
28
24
23
22
I
R
µ
A
at
V
R
V
I
ZM2)
Part Number
mA
110
1N746A
1N747A
1N748A
1N749A
1N750A
1N751A
1N752A
1N753A
1N754A
1N755A
1N756A
1N757A
1N758A
1N759A
3.3
3.6
3.9
4.3
4.7
5.1
5.6
20
6.2
6.8
7.5
8.2
9.1
10
12
10
100
95
85
2
19
17
1
11
1
7
5
6
8
10
17
30
0.1
60
55
50
45
40
35
30
65
75
70
Tolerance and voltage designation (V
Z
)
The type numbers shown have a standard tolerance of ±5% on the nominal zener voltage, C for ±2%, D for ±1%.
2)
Maximum zener current ratings (I
ZM
)
Maximum zener current ratings are based on maximum zener voltage of the individual units and JEDEC 250 mW rating.
http://www.element14.com
http://www.farnell.com
http://www.newark.com
Page <2>
06/04/11 V1.1
Zener Diode
1N746A-1N759A
Characteristics (T
j
= 25°C unless otherwise specified)
http://www.element14.com
http://www.farnell.com
http://www.newark.com
Page <3>
06/04/11 V1.1
Zener Diode
1N746A-1N759A
http://www.element14.com
http://www.farnell.com
http://www.newark.com
Page <4>
06/04/11 V1.1
Zener Diode
1N746A-1N759A
Standard Glass case
JEDEC DO-35
Dimensions: Millimetres
Marking
Important Notice :
This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of
it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces
all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use
made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted.
Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising)