Relay
Contact Data
Contact Form
Contact material
Contact rating
Maximum switching voltage
Maximum switching current
Maximum switching power
Minimum switching load
Maximum contact resistance (Standard type)
Maximum contact resistance (High sensitivity)
Life
Electrical
Mechanical
General Data
Minimum insulation resistance
Dielectric strength
: 1000MΩ 500V dc.
: 750V ac, 1 min between open contacts (Standard type).
500V ac, 1 min between open contacts (High sensitivity).
1000V ac. 1 min between coil and contacts.
: Maximum 7ms.
: Maximum 3ms.
: -25 to +70°C.
: 100,000 operations at nominal load.
: 15,000,000 operations.
: 2 form C
: AuAg overlay, Ag Alloy.
: 1A 120V ac/24V dc.
: 125V ac/30V dc.
: 2A (Standard type), 1A (High Sensitivity).
: 120VA, 30W.
: 5V dc, 10mA.
: 50mΩ (6V dc 0.1A).
: 100mΩ (6V dc 0.1A).
Operate time
Release time
Operate temperature
Shock Resistance
Endurance
Misoperation
Vibration Resistance
Endurance
Misoperation
Humidity
: 1000m/s
2
.
: 100m/s
2
.
: 10 to 55Hz, 1.5mm double amplitude.
: 10 to 55Hz, 1.5mm double amplitude.
: 35 to 95%RH, +40°C.
Page <1>
29/04/11 V1.1
Relay
Characteristic Chart Data
Life Curves
Maximum Switching Power
Contact Current (A)
Contact Voltage (V)
Important Notice :
This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of
it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces
all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use
made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted.
Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising)
is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Multicomp is the registered trademark of the Group. © Premier Farnell plc 2011.
Page <3>
29/04/11 V1.1