Halogen and Antimony Free. “Green” Device (Note 3)
Applications
Open and Close Detect for Flip/Slide Cellular Phones
Smart Cover or Dock Detect for Cellular Phones and Tablets
Cover or Display Switch in Portable PCs (such as Ultrabook™)
Display Switch for Portable PCs
On/Off switch for PDAs and Digital Cameras
Contactless Switch in Consumer Products
Notes:
1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS), 2011/65/EU (RoHS 2) & 2015/863/EU (RoHS 3) compliant.
2. See https://www.diodes.com/quality/lead-free/ for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green" and
Lead-free.
3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and
<1000ppm antimony compounds.
Ultrabook is a trademark of Intel Corporation or its subsidiaries in the U.S. and/or other countries.
6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
7. The absolute maximum V
DD
of 7V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to operate the
device at the absolute maximum rated conditions for any period of time.
Recommended Operating Conditions
(@T
A
= +25°C, unless otherwise specified.)
Symbol
V
DD
T
A
Parameter
Supply Voltage
Operating Temperature Range
Conditions
Operating
Operating
Rating
2.5 to 5.5
-40 to +85
Unit
V
°C
Electrical Characteristics
Symbol
V
OUT
I
OFF
(@ V
DD
= 3V, T
A
= +25°C, unless otherwise specified.)
Conditions
I
OUT
= 1mA
V
OUT
= 5.5V, B < Brp
During ‘Awake’ Period,
T
A
= +25°C, V
DD
= 3V
During ‘Awake’ Period,
T
A
= -40 to +85°C, V
DD
= 2.5 to 5.5V
During ‘Sleep’ Period,
T
A
= +25°C, V
DD
= 3V
During ‘Sleep’ Period,
T
A
= -40 to +85°C, Vdd = 2.5~5.5V
Average Supply Current ,
T
A
= +25°C, V
DD
= 3V
Average Supply Current ,
T
A
= -40 to +85°C, Vdd = 2.5 to 5.5V
Min
—
—
—
—
—
—
—
—
—
—
—
—
Typ
0.1
<0.1
3
3
5
5
8
8
300
75
75
0.1
Max
0.3
1
6
10
10
18
16
23
—
150
150
—
Unit
V
µA
mA
mA
µA
µA
µA
µA
kHz
µs
ms
%
Characteristic
Output On Voltage (V
OL
)
Output Leakage Current
I
DD
(awake)
I
DD
(sleep)
Supply Current
I
DD
(avg)
F
C
Tawake
Tperiod
D.C.
Note:
Chopping Frequency
Awake Time
Period
Duty Cycle
For Design Information Only
(Note 8)
(Note 8)
—
8. When power is initially turned on, V
DD
must be within its correct operating range (2.5V to 5.5V) to guaranteed the output sampling. The output state is
valid after the second operating cycle (typical 150ms).
控制器局部网CAN(Controller Area Network)属于现场总线的一种,是一种有效支持分布式控制或实时控制的串行通信网络,被公认为是最有前途的现场总线之一。 在工业控制系统中,电动执行器是电动单元组合仪表中一个很重要的执行单元。它由控制电路和执行机构两个在电路上完全独立的部分组成,可接收来自调节器的电控信号,将其线性地转换成机械转角或直线位移,用来操纵风门、挡板、阀门等...[详细]