10-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
10-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
10-2000Hz, 4 minutes sweep and 98m/s² (10G) acceleration, 3 directions, 0.5h for each, in non-operation
980m/s² (100G), 6ms, 3 directions, 3 times for each, in non-operation
1.5
18 x 4 x 11.8
In CE-0926: Vin=5V, and Io1=Io2=50mA.
In CE-0927: Vin=3.3V, nominal output voltage, Io=300mA.
In CE-0928: Vin=5.0V, nominal output voltage, Io=300mA.
In CE-0929/0930/0932: Vin=3.3V, nominal output voltage, Io=150mA.
In CE-0931: Vin=3.3V, Io1=Io2=40mA.
For the output side (Io2) of dual-output models (CE-0926/0931), refer to the items of output voltage setting in the instructions.
The maximum output power value is that of nominal output voltage x maximum output current.
Max power total regulation (% ) is the regulation of the set output voltage including load change, input change, and temperature change.
Condition of Io2 for dual-output models (CE-0926/0931): 0.5 x Io1 < Io2 < 1.5 x Io2
In 20MHz, Ta=25°
C.
With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Outline Drawing
Metal case
8-ø0.8
Cut-through hole
1.3
Recommended measurements for board
mounting Pattern prohibited
1.4
1.6
area (CE-0929 only)
1
1
2
3
4
8
7
6
5
18±0.3
0.15±0.1
P=2±0.3
Unit: mm
Case is connected to GND.
Pattern (resist processing)
4max.
(19.4)
15.4
1
CE-09xx
TDK-Lambda
MADE IN JAPAN
Lot No.
11.8±0.3
P P
1.4
P
11
1
Dimensions in m
1 2
9.4
2
Derating Curve
Output power (%)
100
80
60
40
20
0
–40
0
50
80
Ambient temperature (°
C)
Output power derating by ambient temperature
・All specifications are subject to change without notice.
CE-09xx
CE-09xx Specifications
ITEMS/UNIT
MODEL
CE-0970
CE-0994
CE-0972
CE-0993
CE-0995
Input
Output
Function
Environment
Mechanical
Voltage Range Nominal:5VDC
(*1)
Efficiency (typ)
(*2)
Nominal Voltage
Maximum Current
(*3)
Maximum Power
Maximum Line Regulation
Within input voltage range (typ)
Maximum Load Regulation (0-100%)(typ)
Temperature Coefficient (-10 to 50°
C)(typ)
(*4)
Max Power Total Regulation (max)
Maximum Ripple & Noise (typ)
(*5)
Maximum Ripple & Noise (max)
(*5)
Acceptable Output Capacitorco
(*6)
Over Current Protection
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Weight
Size (W x H x D)
V
%
V
mA
W
DC4.5-5.5
82
3.3
360
0.05%
85
12
100
1.2
0.5%
1%
3
140
350
170
15
80
-5
160
0.02%
0.1%
0.3
100
72
-12
66
0.8
0.05%
-15
53
75
-24
33
250
300
22
6.8
Not available
Not available
Not available
℃
-10 to +70
℃
-40 to +85
%
RH 10-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
%
RH 10-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
10-500Hz, 15 minutes sweep and 98m/s² (10G) acceleration, 3 directions, 2h for each, in non-operation
980m/s² (100G), 6ms, 3 directions, 3 times for each, in non-operation
g
1.2
mm
17.5 x 4.3 x 11.8
%
%
mVp-p
mVp-p
μ
F
0.1%
0.3
120
250
68
Available
∓
5
(*1) In nominal input voltage, maximum output current, and Ta=25°
C.
(*2) 15V in CE 0994 is the value when Vset and +Vset are short-circuited. -15V in CE 0993 is the value when Vset and +Vset are short-circuited.
(*3) The maximum output power value is between -10° and +50° For use outside this temperature rage, derating is needed.
C
C.
(*4) Temperature coefficient in -10° - +50°
C
C.
(*5) Frequency range in measurement (50MHz). Ripple & noise value is that in the condition where a specified external output capacitor Co is attached to the output termi-
nal.
(*6) Use an external output capacitor with 3Ωmax. impedance and 0.06 max. loss angle. Recommended capacitor: TE series (MATSUSHITA)
With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Outline Drawing
Metal case
8-ø0.8
Cut-through hole
8
7
6
5
1.3
Recommended measurements for board mounting
1.0
0.65±0.15
(Board thickness)
17.5
4.3max.
P=2.0
Allowable tolerance is 0.3
if not specified separately.
Unit: mm
14.9
(18.9)
(0.7)
・Case is connected to GND.
1
2
3
4
1.4
Derating Curve
Output power (%)
100
80
60
50
40
20
30
50
70 80
Ambient temperature (°
C)
Output power derating by ambient temperature
・All specifications are subject to change without notice.