HLMP-HG65, HLMP-HM65, HLMP-HB65
Precision Optical Performance Red Green and Blue
New 5mm Standard Oval LEDs
Data Sheet
Description
These Precision Optical Performance Oval LEDs are spe-
cifically designed for full color/video and passenger infor-
mation signs. The oval shaped radiation pattern and high
luminous intensity ensure that these devices are excellent
for wide field of view outdoor applications where a wide
viewing angle and readability in sunlight are essential.
The package epoxy contains both UV-A and UV-B inhibi-
tors to reduce the effects of long term exposure to direct
sunlight.
Features
x
Well defined spatial radiation pattern
x
High brightness material
x
Available in Red, Green and Blue color
Red AlInGaP 626 nm
Green InGaN 525nm
Blue InGaN 470nm
x
Superior resistance to moisture
x
Standoff Package
x
Tinted and diffused
x
Typical viewing angle 40° x 100°
Applications
x
Full color signs
Package Dimensions
NOTE:
1.
MEASURED
AT
BASE
OF
LENS.
1.30 ± 0.20
0.051 ± 0.008
0.70
MAX.
0.028
0.50 ± 0.10
0.020 ± 0.004 SQ TYP.
3.80 ± 0.20
0.150 ± 0.008
10.80 ± 0.50
0.425 ± 0.020
5.20
± 0.20
0.205 ± 0.008
CATHODE
LEAD
24.00
MIN.
0.945
MIN.
2.54 ± 0.30
0.10 ± 0.012
1.00
MIN.
0.039
7.00 ± 0.20
0.276 ± 0.008
1.02
MAX.
0.040
MAx.
Notes:
All dimensions in millimeters (inches).
Tolerance is ± 0.20mm unless other specified
CAUTION:
INGaN devices are Class 1C HBM ESD sensitive per JEDEC Standard. Please observe appropriate
precautions during handling and processing. Refer to Application Note AN – 1142 for additional details.
Device Selection Guide
Part
Number
HLMP-HG65-VY0xx
HLMP-HM65-Y30xx
HLMP-HB65-QU0xx
Color
and
Dominant
Wavelength
Od
(nm) Typ
Red 626
Green 525
Blue 470
Luminous Intensity Iv
(mcd) at
20
mA-Min
[1]
1150
1990
460
Luminous Intensity Iv
(mcd) at
20
mA-Max
[1]
2400
5040
1150
Tolerance for each intensity limit is ± 15%.
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package and it is tested in pulsing condition.
Part Numbering System
HLMP-H x
65
- x x x xx
Packaging
Option
ZZ:
Flexi Ammopack
DD: Ammopacks
Color
Bin
Selection
0: Open distribution
Maximum
Intensity
Bin
0: No maximum intensity
limit
Minimum
Intensity
Bin
Refer to Device Selection Guide.
Standoff/Non Standoff
5: Standoff
Color
G: Red 626
M: Green 525
B: Blue 470
Package
H: 5mm Standard Oval 40° x
100°
Note:
Please refer to AB 5337 for complete information about part numbering system.
2
Absolute
Maximum
Ratings
T
J
= 25°C
Parameter
DC Forward Current
[1]
Peak Forward Current
Power Dissipation
Reverse Voltage
LED Junction Temperature
Operating Temperature Range
Storage Temperature Range
Notes:
1. Derate linearly as shown in Figure 4.
2. Duty Factor 30%, frequency 1KHz.
3. Duty Factor 10%, frequency 1KHz.
Red
50
100
[2]
120
5 (I
R
= 100 μA)
130
-40 to +100
-40 to +100
Green and Blue
30
100
[3]
116
5 (I
R
= 10 μA)
110
-40 to +85
-40 to +100
Unit
mA
mA
mW
V
°C
°C
°C
Electrical / Optical Characteristics
T
J
= 25°C
Parameter
Forward Voltage
Red
Green
Blue
Reverse Voltage
Red
Green & blue
Dominant Wavelength
[1]
Red
Green
Blue
Peak Wavelength
Red
Green
Blue
Thermal Resistance
Luminous Efficacy
[2]
Red
Green
Blue
Symbol
V
F
Min.
1.8
2.8
2.8
Typ.
2.1
3.2
3.2
Max.
2.4
3.8
3.8
Units
V
Test
Conditions
I
F
= 20 mA
V
R
5
5
V
I
F
= 100 μA
I
F
= 10 μA
nm
I
F
= 20 mA
626
525
470
634
516
464
240
150
530
65
630
540
480
nm
Peak of Wavelength of Spectral
Distribution at I
F
= 20 mA
LED Junction-to-Pin
Emitted Luminous Power/Emitted
Radiant Power
O
d
618
520
460
O
PEAK
RT
J-PIN
K
V
°C/W
lm/W
Notes:
1. The dominant wavelength is derived from the chromaticity Diagram and represents the color of the lamp
2. The radiant intensity, Ie in watts per steradian, may be found from the equation Ie = I
V
/K
V
where I
V
is the luminous intensity in candelas and
K
V
is
the luminous efficacy in lumens/watt.
3