LH15-20BxxMU series ----- is a compact size power converter offered by Mornsun. It features universal input voltage, taking both DC and AC
Input voltage, low power consumption, high efficiency, high reliability, safer isolation. Meets EN60601-1, ANSI/AAMI ES60601-1,
CAN/CSA-C22.2 No. 60601-1 standards (2xMOPP), and widely used in medical, industrial, instruments, telecommunication and civil
applications. For harsh EMC environment, the application circuit in the datasheet is strongly recommended.
Selection Guide
Certification
Part No.
LH15-20B05MU
LH15-20B12MU
CSA/CE
LH15-20B15MU
LH15-20B18MU
LH15-20B24MU
15W
Output Power
14W
Nominal Output Voltage and
Current (Vo/Io)
5V/2800mA
12V/1250mA
15V/1000mA
18V/833mA
24V/625mA
Efficiency
(230VAC, %/Typ.)
78
83
83
84
86
Max. Capacitive
Load(µF)
8000
4000
3000
2000
800
Input Specifications
Item
Input Voltage Range
Input frequency*
Input current
Inrush current
Leakage current
Recommended External Input
Fuse (Chassis mounting, DIN-Rail
mounting package series include fuse)
Hot Plug
*Medical Certification Input frequency range:47-63 Hz
Operating Conditions
AC input
DC input
115VAC
230VAC
115VAC
230VAC
Min.
85
100
47
--
--
--
--
Typ.
--
--
--
--
--
10
20
Max.
264
370
440
0.37
0.22
--
--
Unit
VAC
VDC
Hz
A
0.1mA RMS typ./264VAC/60Hz
2A/250V, slow fusing
Unavailable
Output Specifications
Item
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise*
Temperature Coefficient
20MHz bandwidth (peak-peak value)
Full load
Operating Conditions
Min.
--
--
--
--
--
Typ.
±2
±0.5
±1
50
±0.02
Max.
--
--
--
100
--
mV
%/°C
%
Unit
2017.04.25-A/2
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH15-20BxxMU Series
Short Circuit Protection
Over-current Protection
5VDC Output
Over-voltage Protection
12 /15VDC Output
18VDC Output
24VDC Output
Stand-by Power Consumption
Min. Load
Hold-up Time
115VAC input
230VAC input
--
0
--
--
--
--
15
80
Continuous, self-recovery
≥110%Io
self-recovery
≤7.5VDC
≤20VDC
≤25VDC
≤30VDC
0.1
--
--
--
W
%
ms
Note: * Ripple and noise are measured by “parallel cable” method, please see AC-DC Converter Application Notes for specific operation.
General Specifications
Item
Isolation Voltage
Storage Temperature
Storage Humidity
Welding Temperature
Switching Frequency
Power Derating
Safety Standard
Safety Certification
Safety Class
Insulation Level
MTBF
Primary to secondary
-40℃ to -25℃
+55℃ to +70℃
Wave-soldering
Manual-welding
--
3.3
Input-output
Operating Temperature
Operating Conditions
Test time: 1min Leakage current≦5mA
Min.
4000
-40
-40
--
Typ.
--
--
--
--
Max.
--
+70
+85
95
Unit
VAC
°C
%RH
260 ± 5℃; time: 5 - 10s
360 ± 10℃; time: 3 - 5s
65
--
--
--
kHz
%/°C
3.3
--
--
EN60601-1, ANSI/AAMI ES60601-1,
CAN/CSA-C22.2 No. 60601-1
EN60601-1, ANSI/AAMI ES60601-1,
CAN/CSA-C22.2 No. 60601-1
CLASSⅡ
2xMOPP
MIL-HDBK-217F@25°C≥ 300,000 h
Physical Specifications
Casing Material
Horizontal package
Dimension
A2 chassis mounting
A4 Din-Rail mounting
Horizontal package
Weight
Cooling method
A2 chassis mounting
A4 Din-Rail mounting
Black flame-retardant and heat-resistant plastic (UL94 V-0)
62.00*45.00* 22.50mm
96.10*54.00*31.00mm
96.10*54.00*35.60 mm
85g (Typ.)
135g (Typ.)
175g (Typ.)
Free air convection
EMC Specifications
EMI
CE
RE
ESD
RS
EFT
EMS
Surge
CS
Voltage dips, short
interruptions and voltage
variations immunity
EN55011(CISPR11) / EN55022(CISPR22) CLASS B
EN55011(CISPR11) / EN55022(CISPR22) CLASS B
IEC/EN61000-4-2
IEC/EN61000-4-3
IEC/EN61000-4-4
IEC/EN61000-4-4
IEC/EN61000-4-5
IEC/EN61000-4-5
IEC/EN61000-4-6
IEC/EN61000-4-11
Contact ±6KV/Air ±8KV
10V/m
±2KV
±4KV (See Fig. 2 for recommended circuit)
line to line ±1KV
line to line ±2KV (See Fig. 2 for recommended circuit)
10Vr.m.s
0%,70%
Perf. Criteria B
perf. Criteria A
perf. Criteria B
perf. Criteria B
perf. Criteria B
perf. Criteria B
perf. Criteria A
perf. Criteria B
2017.04.25-A/2
Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH15-20BxxMU Series
Product Characteristic Curve
O u tp u t P o w e r P e rc e n ta g e ( % )
O u t p u t P o w e r P e rc e n t (% )
Te m p e ra t u r e D e ra t in g C u r v e
100
80
60
50
40
20
-4 0
-25
55
70
A m b ie n t t e m p e ra t u r e (
℃
)
In p u t v o lt a g e : 8 5 - 2 6 4 VA C
100-370VD C
In p u t V o lt a g e D e ra tin g C u r v e
100
80
75
60
40
20
85
100
100
120
240
340
I n p u t V o lt a g e
264
370
VA C
VDC
A m b ie n t t e m p e r a t u r e : 2 5
℃
O u tp u t P o w e r P e rc e n ta g e( % )
A ltitu d e D e r a tin g C u r v e
10 0
80
60
40
20
0
30 00
A ltitu d e (m )
50 00
Note:
①When
input 85-100VAC/100-120VDC, it need to be voltage derated on basis of temperature derating;
②Altitude
should be derated based on temperature derating when it is 3000 - 5000m;
③This
product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE.
Design Reference
1. Typical application circuit
A C (L)
FU S E
A C (L )
+ Vo
C1
C2
TVS
RL
Element model
LH15-20B05MU
LH15-20B12MU
LH15-20B15MU
LH15-20B18MU
LH15-20B24MU
C2(µF)
680
470
220
220
68
TVS1
SMBJ7.0A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ30A
AC -DC
A C (N )
A C (N )
- Vo
Fig. 1: Typical application circuit
Note:
Note: Output filtering capacitors C2 is electrolytic capacitor, it is recommended to use high frequency and low impedance electrolytic capacitor. For
capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitor voltage reduced to at least 80%. C1 is ceramic capacitor, which is
used to filter high-frequency noise, advice use 1
µ
F. TVS is a recommended component to protect post-circuits if converter fails. External input FUSE model is
recommended to use 2A/250V slow fusing.
2. EMC solution-recommended circuit
F US E
A C ( L)
C a n u se M O R N SU N
'
s F C -L X 1 D
LD M
LC M
A C ( L)
C Y1
+V o
C1
C2
TV S
RL
MOV 1
CX
A C -D C
C Y2
-V o
+
A C( N )
A C( N )
Fig 2: EMC Recommended circuit with higher requirements
2017.04.25-A/2
Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH15-20BxxMU Series
Element model
MOV1
CY1, CY2
CX
LCM
LDM
FC-LX1D
FUSE
Recommended value
S14K300
1nF/400VAC
0.1μF/275VAC
10mH, recommended to use MORNSUN’s FL2D-Z5-103
4.7μH/2A
2KV/4KV EMC filter
2A/250V slow fusing, necessary
3. For more information Please find the application note on
www.mornsun-power.com
Dimensions and Recommended Layout
A2 Dimensions
2017.04.25-A/2
Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH15-20BxxMU Series
A4 Dimensions
Note:
1. Packing information please refer to Product Packing Information which can be downloaded from
www.mornsun-power.com.
Packing
bag number of Horizontal package : 58220006, the Packing bag number of A2/A4 package:58220010;
2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all
parameters in the datasheet;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25
℃,
humidity<75% with nominal
4.
5.
6.
7.
input voltage and rated output load;
All index testing methods in this datasheet are based on our Company’s corporate standards;
The performance parameters of the product models listed in this manual are as above, but some parameters of non-standard model
products may exceed the requirements mentioned above. Please contact our technicians directly for specific information;
We can provide product customization service;
Specifications are subject to change without prior notice.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: info@mornsun.cn
2017.04.25-A/2
Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
EtherCAT(Ethernet for Control Automation Technology)是一种基于以太网的开发构架的实时工业现场总线通讯协议,EtherCAT是最快的工业以太网技术之一,同时它提供纳秒级精确同步。相对于设置了相同循环时间的其他总线系统,EtherCAT系统结构通常能减少25%-30%的CPU负载,EtherCAT的出现为系统的实时性能和拓扑的灵活性树立了新的标准。...[详细]
For healthcare professionals, accurate diagnosis and treatment are crucial for a clear picture of a person's health. However, healthcare professionals often rely on tests at medical facilities, cli...[详细]