DUAL GN SERIES
PANEL MOUNT
Features
•
•
•
•
•
•
•
Current rating 25 and 40 Amps
Output voltage 24-280 VAC and 48-660 VAC
Direct bond copper substrate
Back to back dual SCR output
4000 VAC optical isolation
Zero Voltage and Instantaneous Turn-On
UL/cUL Recognized, CE Compliant
SPECIFICATIONS
Product Selection
1/4” Quick Connect 280 VAC
Control Voltage
4-15 VDC
17-32 VDC
25 A
84140000
84140410
1/4” Quick Connect 660 VAC
25 A
84140500
84140510
Locking Connector 280 VAC
25 A
84140800
84140810
40 A
84140200
84134210
40 A
84140600
84140610
40 A
84140900
84140910
Output Specifications
(1)
Description
Operating Voltage [Vrms]
Transient Voltage(t=1 min.) [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage
(@ max. line voltage) [mArms]
280 VAC
24-280
550
0.1
660 VAC
48-600
1000
0.25
Page 1
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
Output Specifications
(1)
Description
Maximum Load Current [Arms]
Minimum Load Current [mArms]
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
1 Second surge current (50/60 Hz @ Ta=25°C) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
Maximum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
25 A
25
100
275/300
85
1.4
0.6
380/370
500
40 A
40
100
710/750
150
1.3
0.4
2520/2320
500
Input Specifications
(1)
Description
Control Voltage Range [Vdc]
Minimum Turn-On Voltage [Vdc]
Must Turn-Off Voltage [Vdc]
Minimum Input Current (for on-state) [mA]
Maximum Input Current [mA]
Nominal Input Impedance [Ohms]
Maximum Turn-On Time [msec]
(2)
Maximum Turn-Off Time [msec]
84140x0x
4-15
4
1
7.5
34
500
1/2 Cycle
1/2 Cycle
84140x1x
17-32
17
1
13
24
1500
General Specifications
(1)
Description
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Input to Output Isolation
Input/Output to Ground Isolation
Input to Output Capacitance
Operation Frequency
Housing Material
Weight (typical)
Parameters
-40 to 80°C
-40 to 100 °C
4000 Vrms
2500 Vrms
8 pF
47 to 63 Hz
UL94 V-0 (self extinguishing)
3.2 oz (91.5g)
MECHANICAL SPECIFICATIONS
(1)
Tolerance: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
1.78
[45.3]
0.18
[4.7]
0.56
[14.3]
1.17
[29.7]
1.00
[25.4]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
p
l
i
^f
q
a
b
^
=
v
p
o
q
b
i
1.87
[47.5]
1.21
[30.6]
Input A
+
-
+ Input B
0.86
[21.8]
2.30
[58.4]
1.31
[33.2]
-
0.60
[15.2]
0.74
[18.8]
Pin .025 SQ
.100 CENTERS
Mating Connector for 841408xxx and 841409xxx
Molex # 50-57-9404 without pins
Crimp Pins Molex # 16-02-0103
0.45
[11.5]
(4 places)
Page 2
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
WIRING DIAGRAM
EQUIVALENT CIRCUIT BLOCK DIAGRAMS
THERMAL DERATE INFORMATION
Page 3
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
ORDERING OPTIONS
Example : 84140010
84140
0
1
0
Family
1/4” Quick Connect 280 VAC
1/4” Quick Connect 660 VAC
Locking Connector 280 VAC
Rated Load Current
1/4” Quick Connect 280 VAC
0 :
25 Amp/Zero Voltage Turn-On
1 :
25 Amp/Instantaneous Turn-On
2 :
40 Amp/Zero Voltage Turn-On
3 :
40 Amp/Instantaneous Turn-On
1/4” Quick Connect 660 VAC
5 :
25 Amp
6 :
40 Amp
Locking Connector 280 VAC
8 :
25 Amp
9 :
40 Amp
Control Voltage
1/4” Quick Connect 280 VAC
0 :
4-15 VDC
1 :
17-32 VDC
1/4” Quick Connect 660 VAC
0 :
4-15 VDC
1 :
17-32 VDC
Locking Connector 280 VAC
0 :
4-15 VDC
1 :
17-32 VDC
Operating Voltage
1/4” Quick Connect 280 VAC
0 :
24-280 VAC
1/4” Quick Connect 660 VAC
0 :
48-660 VAC/Zero Voltage Turn-On
1 :
48-660 VAC/Instantaneous Turn-On
Locking Connector 280 VAC
0 :
24-280 VAC/Zero Voltage Turn-On
1 :
24-280 VAC/Instantaneous Turn-On
GENERAL NOTES
(1)
(2)
All parameters at 25°C unless otherwise specified.
Turn-on time for Instantaneous turn-on versions is 0.02 msec.
For additional information or specific questions, contact Crydom Technical Support.
Page 4
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
AGENCY APPROVALS & CERTIFICATIONS
EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:
Certified according to EN 62314:2006
IEC 61000-4-2 Electrostatic Discharge Level 3
IEC 61000-4-4 Electrically Fast Transients Level 3
IEC 61000-4-5 Electrical Surges Level 3
WARNINGS
RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
• The product’s side panels may be hot, allow the product to cool before touching
• Follow proper mounting instructions including torque values
• Do not allow liquids or foreign objects to enter this product
Failure to follow these instructions can result in serious injury, or equipment damage.
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
• Disconnect all power before installing or working with this equipment
• Verify all connections and replace all covers before turning on power
Failure to follow these instructions will result in death or serious injury.
Page 5
Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that
incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible
for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have
been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that
specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements,
improvements and other changes to its data sheets or components without notice.
Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO
OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND
NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS
ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE
OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS
ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET
ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD
TO SENSATA DATA SHEETS OR USE THEREOF.
All products are sold subject to Sensata’s terms and conditions of sale supplied at
www.sensata.com
SENSATA ASSUMES NO LIABILITY
FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY
RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS,
AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION
OR SUPPORT THAT MAY BE PROVIDED BY SENSATA.
Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA.
CONTACT US
Americas
+1 (877) 502 5500
sales.crydom@sensata.com
Europe, Middle East & Africa
+44 (1202) 416170
ssr-info.eu@sensata.com
Asia Pacific
sales.isasia@list.sensata.com
China
+86 (21) 2306 1500
Japan
+81 (45) 277 7117
Korea
+82 (31) 601 2004
India
+91 (80) 67920890
Rest of Asia
+886 (2) 27602006
ext 2808
Copyright © 2018 Sensata Technologies, Inc.
Rev:12/04/18 ECN 20395 FDE-07-01 Rev. B
www.sensata.com