Features
Regulated
Converters
●
●
●
●
●
●
●
Connector Set available
Class II Power Supply
Universal Input Voltage Range
compact 4“ x 2“ size
3kVAC Isolation
OCP, OVP, SCP
Standby Power ErP conform (<0.5W)
POWERLINE
AC/DC-Converter
with 3 year Warranty
Description
The RAC48/OF series offers compact AC/DC open frame power supplies
with universal AC input (90-264VAC) and fully protected DC outputs which
are trimmable to compensate for voltage drops on the output connections.
The power supplies are CB, UL, and CE certified and ErP conform.
Uses include industry controls, test and measurement systems and energy
efficient products.
Selection Guide
Part
Number
Input Output
Output
Voltage Adj.
Range Voltage Current Range Range *
(VAC)
(VDC)
(A)
(V)
RAC48-05S/OF 90-264
5
0-8
4.8-5.2
RAC48-12S/OF 90-264
RAC48-15S/OF 90-264
RAC48-24S/OF 90-264
12
15
24
0-4
0-3.2
0-2
11.4-12.6
14.2-16
23-25
Output
Power
(W)
40
48
48
48
Efficiency Max.
typ.
Capacitive
%
Load
79
18800µF
82
84
85
18800µF
12700µF
4700µF
48 Watt
Open Frame
Single Output
* refer to „Package Style and Pinning“
Specifications
(typical at 25°C and 230VAC)
Input Voltage Range
Rated Power
Input Frequency Range (for AC Input)
Operating Frequency
Input Current (full load)
Inrush Current (Cold Start)
No Load Power Consumption
Start-up Time (at cold first start)
Rise Time
Hold Time
Leakage Current
Output Voltage Accuracy
Output Ripple and Noise (20MHz limited)
115VAC/230VAC
Full Load
115VAC, Full Load
230VAC, Full Load
240VAC
24VDC
5VDC
12VDC
15VDC
(measured with 0.1μF & 47μF parallel capacitor)
90-264VAC or 127-370VDC
48 Watts max.
47-63Hz
65kHz typ.
115VAC
230VAC
115VAC
230VAC
1.5A max.
1A max.
30A typ.
60A typ.
<0.5W
500ms
<30ms
13ms typ.
60ms typ.
<0.75mA
±1%
±2%
80mVp-p max.
120mVp-p max.
2011/65/EU
6/6
RoHS
E196683
CB-Report
UL-60950-1 Certified
EN-60950-1 Certified
EN-55022 Certfied
EN-55024 Certified
RAC48/OF
Derating-Graph
(Ambient Temperature)
100
Output Power (%)
80
50
60
40
20
0
0
20
50
-20
70
Ambient Temperature Range (°C)
(includes Line-, Load-regulation and Set-up Tolerance)
05, 12, 15VDC
150mVp-p max.
200mVp-p max.
3kVAC / 1 minute
1.5kVAC / 1 minute
0.5kVAC / 1 minute
100 MΩ
Hiccup Mode, Automatic Restart
5.75-6.5VDC
13.5-15VDC
16.9-18.75VDC
27-30VDC
continued on next page
24VDC
I/P to O/P
I/P to FG
O/P to FG
Isolation Voltage
Isolation Resistance
Short Circuit Protection
Over Voltage Protection
500VDC
5VDC
12VDC
15VDC
Latch Mode, re-power on to recover
Over Load Protection
24VDC
115-150% rated output power, Hiccup Mode, Automatic Restart
www.recom-power.com
REV: 3/2017
PA-53
POWERLINE
AC/DC-Converter
Specifications
(typical at 25°C and 230VAC)
Operating Temperature Range
Storage Temperature Range
Operation Humidity
Storage Humidity
Vibration
Weight
Dimensions (LxWxH)
Package Quantity
Package Dimensions Carton (LxWxH)
MTBF
Certifications:
General Safety
IEC/EN General Safety
EMC
(using MIL-HDBK-217F, 25°C)
non-condensing
Full Load without derating
with derating
RAC48-xx/OF
Series
-20°C to +50°C
-20°C to +70°C
-40°C to +80°C
20% - 90% RH
10% - 90% RH
10-500Hz, 2G, 10 Min. along X, Y and Z
145g
101.6 x 50.8 x 30mm
30pcs / carton
325 x 270 x 220mm
>450 x 10³ hours
UL-60950-1 2nd
IEC/EN-60950-1 2nd
EN55022, Class B
EN55024
FCC, Part 15, Class B
EN61000-3-2
EN61000-3-3
EN61000-4-2, 3, 4, 5, 6, 8, 11, Critertia A
EN61000-6-3
2004/125/EC
Conducted and Radiated
Immunity
Harmonics
Report: E196683
Report: PSE103-0658
Report: HA080035-SCCE
Report: HA080035-SCCE
Report: HA080035-SBFD
Report: HA080035-SCCE
ErP
Emission
Report: HA080035-SCCE
complies to European Directive for Energy Related Products
Input Voltage vs Load
100
Output Power [%]
80
60
40
20
0
90 110 115
230
264
RAC48/OF
Input Voltage [VAC]
Package Style and Pinning
101.6
95.3
POWER LED
2
1
1
3
4
VR
3.175
TRIM
AC Input Connector (CN1):
Pin#
Terminal
1 AC/N
WST I39606PS-2
or equivalent
2 AC/L
Mating Housing
WST P3-I39606
or equivalent
50.8
44.5
CN1
CN2
2
A
B
3.175
F.G.
F.G.
4x
3.3
DC Output Connector (CN2):
Pin#
Terminal
1, 2 V+
WST I39606PS-2
or equivalent
3, 4 V-
Mating Housing
WST P4-I39606
or equivalent
Notes
Note1:
Mounting holes A, B must be grounded for EMI (Filter Ground).
Note:
Detail information about the connectors on www.wst.com.tw
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-54
30
REV: 3/2017
www.recom-power.com