RP
RPM6000 Series
RPM6000
MILITARY/ COTS TO 60A
NON-GRND & GRND RETURNS
MIL-STD-461/ DO-160
RADIUS POWER
Your Power Partner
MIL/COTS DC EMI Power Line Filter
SPECIFICATIONS
Operating Freq.
Max. Operating Voltage
Ambient Temperature
Hipot Rating (L-G)
Terminals (-T)
Applications
:
:
:
:
:
:
DC
400VDC
-40 to 70C
1800VDC
S: 5/10/20/30A (M5)
50/60A (M6)
Mil-461/ DO-160 (2
Line systems w/ non-
ground and ground
return
FREQ (MHz)
CM(dB)
DM(dB)
TYPICAL INSERTION LOSS, dB
(50/50ohm)
.01
22
28
.15
38
48
.5
1
10
40
45
45
52
50
50
30
35
30
Call for other termination types (e.g. Circular Mil-
Connectors, etc.)
SCHEMATIC
PART NUMBER/ ORDERING
RPM6000
-X
(Amps)
5
10
20
30
50
60
-T
S
Weight
LBS (KG)
Typ.
1.0 (0.4)
1.0 (0.4)
2.7 (1.2)
2.7 (1.2)
6.0 (2.7)
8.5 (3.9)
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
151
RP
RADIUS POWER
Your Power Partner
RPM6000
Mechanical Dimensions
5/10Amp
20/30Amp
50Amp
60Amp
TYPICAL TOLERANCE: +/-0.02 (0.50)
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
www.radiuspower.com
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
152