Operating Temperature Range ........................... -40°C to +85°C
Junction Temperature ......................................................+150°C
Storage Temperature Range ............................ -65°C to +150°C
Lead Temperature (soldering, 10s) ................................. +300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Package Information
PACKAGE TYPE: 6 µDFN
Package Code
Outline Number
L611+1
21-0147
For the latest package outline information and land patterns (footprints), go to
www.maximintegrated.com/packages.
Note that a “+”,
“#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing
pertains to the package regardless of RoHS status.
Electrical Characteristics
PARAMETER
Operating Voltage
Quiescent Current
Latchoff Current (Note 2)
Shutdown Current
Shutdown Reverse Leakage
Forward-Current Limit
(VIN = +2.3V to +5.5V, TA = -40°C to +85°C, unless otherwise noted. Typical values are at VIN = +3.3V, TA = +25°C.) (Note 1)
SYMBOL
V
IN
I
Q
I
LATCH
I
SHDNRV
I
FWD
I
SHDN
CONDITIONS
V
ON
= V
IN
, I
OUT
= V
IN
= +2.3V to +5.0V
0, switch on
V
IN
= +5.0V to +5.5V
V
ON
= V
IN
= 3.3V, after an overcurrent fault
(MAX4826/MAX4828/MAX4830)
V
ON
= 0, I
OUT
= 0mA
V
ON
= 0, V
IN
= +2.3V, V
OUT
= +5.5V
(MAX4826/MAX4827/MAX4830/MAX4831)
R
L
= 10Ω
(MAX4828/MAX4829) R
L
= 5Ω
V
OUT
- V
IN
< 0.5V
(MAX4826/MAX4827/MAX4830/MAX4831)
V
OUT
- V
IN
< 0.5V (MAX4828/MAX4829)
MAX4826–MAX4829
MAX4830/MAX4831
V
ON
= V
IN
or GND
V
IN
= +5.5V, V
ON
= 0, V
OUT
= 0
Rising edge
T
A
= +25°C, I
OUT
= 20mA
On-Resistance
R
ON
T
A
= -40°C to
+85°C,
I
OUT
= 20mA
(MAX4826–MAX4829)
(MAX4830/MAX4831)
(MAX4826–MAX4829)
(MAX4830/MAX4831)
2.0
MIN
2.3
TYP
65
8
0.01
0.01
50
100
MAX
5.5
100
120
15
1
1
120
240
120
1.0
0.5
-1
0.01
1.8
100
0.7
1.4
1.0
2.0
1.3
2.6
V
Ω
240
10.0
5.0
+1
1
2.2
mA
mA
µA
µA
V
mV
UNITS
V
µA
µA
µA
µA
mA
Reverse-Current Limit
No-Load Threshold
ON Input Leakage
Off-Switch Leakage
Undervoltage Lockout
Undervoltage Lockout Hysteresis
I
REV
I
NLTH
I
ONLK
I
SWLK
UVLO
UVLO
HYS
ON Input-Logic-High Voltage
V
IH
www.maximintegrated.com
Maxim Integrated
│
2
MAX4826–MAX4831
50mA/100mA Current-Limit Switches
with NO-LOAD Flag in µDFN
Electrical Characteristics (continued)
PARAMETER
ON Input-Logic-Low Voltage
FFLG, NOLD
Output-Logic-Low
Voltage
FFLG, NOLD
Output-High
Leakage Current
Thermal Shutdown
Thermal-Shutdown Hysterisis
DYNAMIC
Turn-On Time
Turn-Off Time
Blanking Time
Short-Circuit Current-Limit
Response Time
No-Load-Detection Response
Time
Retry Time
t
BLANK
SYMBOL
V
IL
(VIN = +2.3V to +5.5V, TA = -40°C to +85°C, unless otherwise noted. Typical values are at VIN = +3.3V, TA = +25°C.) (Note 1)
CONDITIONS
I
SINK
= 1mA
V
IN
= V
FFLG
= V
NOLD
= +5.5V
+150
15
ON from low to high; I
OUT
= 10mA,
C
L
= 0.1µF (Note 3)
ON from high to low; I
OUT
=10mA,
C
L
= 0.1µF (Note 3)
Overcurrent fault
V
ON
= V
IN
= +3.3V, short circuit applied to
OUT
I
OUT
falling step signal from 15mA to 0mA,
C
L
= 0.1µF
Overcurrent fault (Figure 2) (Note 4)
50
30
14
5
60
196
840
60
MIN
TYP
MAX
0.8
0.4
1
UNITS
V
V
µA
°C
°C
µs
ns
ms
µs
µs
ms
t
RETRY
Note 1:
All parts are 100% tested at T
A
= +25°C. Limits at T
A
= -40°C to +85°C are guaranteed by design.
Note 2:
Latchoff current does not include the current flowing into
FFLG
and
NOLD.
Note 3:
Turn-on time is defined as the time taken for the current through the switch to go from 0mA to full load. Turn-off time is
defined as the time taken for the current through the switch to go from full load to 0mA.
Note 4:
Retry time is typically 14x the blanking time.
Typical Operating Characteristics
(VIN = +3.3V, TA = +25°C, unless otherwise noted.)
QUIESCENT SUPPLY CURRENT
vs. SUPPLY VOLTAGE
MAX4826 toc01
MAX4826 toc02
80
SUPPLY CURRENT (µA)
70
60
50
40
30
20
10
0
V
ON
= V
IN
V
IN
= +2.3V TO +5.5V
80
SUPPLY CURRENT (µA)
70
60
50
40
30
20
10
V
ON
= V
IN
V
IN
= 5V
V
IN
= 3.3V
V
ON
= V
IN
LATCHOFF CURRENT (µA)
V
IN
= 5V
V
IN
= 3.3V
2.3
2.7
3.1
3.5
3.9
4.3
4.7
5.1
5.5
0
-40
-15
10
35
60
85
-40
-15
10
35
60
85
SUPPLY VOLTAGE (V)
TEMPERATURE (°C)
TEMPERATURE (°C)
www.maximintegrated.com
Maxim Integrated
│
3
MAX4826 toc03
90
90
QUIESCENT SUPPLY CURRENT
vs. TEMPERATURE
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
LATCHOFF CURRENT
vs. TEMPERATURE
MAX4826–MAX4831
50mA/100mA Current-Limit Switches
with NO-LOAD Flag in µDFN
Typical Operating Characteristics (continued)
(VIN = +3.3V, TA = +25°C, unless otherwise noted.)
SHUTDOWN SUPPLY CURRENT
vs. TEMPERATURE
MAX4826 toc04
MAX4826 toc05
SHUTDOWN LEAKAGE CURRENT (nA)
SHUTDOWN SUPPLY CURRENT (nA)
1
0.1
V
IN
= 5V
0.01
V
IN
= 3.3V
1
0.1
V
IN
= 5V
0.01
V
IN
= 3.3V
REVERSE LEAKAGE CURRENT (nA)
1
0.1
0.01
0.001
V
ON
= V
IN
= OV
V
OUT
= 5V
0.001
0.001
0.0001
-40
-15
10
35
60
85
0.0001
-40
-15
10
35
60
85
0.0001
-40
-15
10
35
60
85
TEMPERATURE (°C)
TEMPERATURE (°C)
TEMPERATURE (°C)
MAX4826 toc07
LATCHOFF-LEAKAGE CURRENT (nA)
V
ON
= V
IN
= 3.3V
0.1
V
IN
= 5V
0.01
V
IN
= 3.3V
NORMALIZED R
ON
1.0
0.8
0.6
0.4
0.2
OUTPUT CURRENT (mA)
1
1.2
MAX4826 toc08
250
200
150
100
50
0
MAX4826/MAX4827/MAX4830/MAX4831
MAX4828/MAX4829
0.001
0.0001
-40
-15
10
35
60
85
0
-40
-15
10
35
60
85
0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3
V
IN
- V
OUT
(V)
TEMPERATURE (°C)
TEMPERATURE (°C)
MAX4826 toc10
FFLG-BLANKING
TIME (ms)
TURN-ON/OFF TIMES (µs)
10
1
0.1
ON
35
30
25
20
15
10
V
IN
= 3.3V
V
IN
= 5V
OFF
0.01
I
LOAD
= -10mA
-40
-15
10
35
60
85
TEMPERATURE (°C)
0.001
-40
-15
10
35
60
85
TEMPERATURE (°C)
MAX4826 toc11
100
SWITCH TURN-ON/OFF TIMES
vs. TEMPERATURE
40
FFLG-BLANKING
TIMEOUT
vs. TEMPERATURE
www.maximintegrated.com
Maxim Integrated
│
4
MAX4826 toc09
10
LATCHOFF-LEAKAGE CURRENT
vs. TEMPERATURE
NORMALIZED ON-RESISTANCE
vs. TEMPERATURE
1.4
300
OUTPUT CURRENT
vs. OUTPUT VOLTAGE
MAX4826 toc06
10
10
SHUTDOWN LEAKAGE CURRENT
vs. TEMPERATURE
10
SHUTDOWN REVERSE LEAKAGE CURRENT
vs. TEMPERATURE
MAX4826–MAX4831
50mA/100mA Current-Limit Switches
with NO-LOAD Flag in µDFN
Typical Operating Characteristics (continued)
(VIN = +3.3V, TA = +25°C, unless otherwise noted.)