1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may
cause permanent damage to the device. This is a stress rating only and functional
operation of the device at these or any other conditions above those indicated in
the operational sections of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect reliability.
2. All device terminals except FCT162XXX Output and I/O terminals.
3. Output and I/O terminals for FCT162XXX.
GND
1
A
6
1
A
7
1
A
8
2
A
1
2
A
2
2
A
3
GND
1
B
6
1
B
7
1
B
8
2
B
1
2
B
2
2
B
3
CAPACITANCE
(T
A
= +25°C, f = 1.0MHz)
Symbol
C
IN
C
OUT
Parameter
(1)
Input Capacitance
Output Capacitance
Conditions
V
IN
= 0V
V
OUT
= 0V
Typ.
4.5
5.5
Max.
6
8
Unit
pF
pF
NOTE:
1. This parameter is measured at characterization but not tested.
GND
2
A
4
2
A
5
2
A
6
GND
2
B
4
2
B
5
2
B
6
PIN DESCRIPTION
Pin Names
xAx
xBx
xCLKAB, xCLKBA
xSAB, xSBA
xOEAB xOEBA
Description
Data Register A Inputs
Data Register B Outputs
Data Register B Inputs
Data Register A Outputs
Clock Pulse Inputs
Output Data Source Select Inputs
Output Enable Inputs
V
CC
2
A
7
2
A
8
V
CC
2
B
7
2
B
8
GND
2
SAB
2
CLK AB
GND
2
SBA
2
CLKBA
2
OEBA
2OEA B
SSOP/ TSSOP
TOP VIEW
2
IDT74FCT16652T/AT/CT
FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
INDUSTRIAL TEMPERATURE RANGE
FUNCTION TABLE
Inputs
xOEAB
L
L
X
H
L
L
L
L
H
H
H
xOEBA
H
H
H
H
X
L
L
L
H
H
L
xCLKAB
H or L
↑
↑
↑
H or L
↑
X
X
X
H or L
H or L
xCLKBA
H or L
↑
H or L
↑
↑
↑
X
H or L
X
X
H or L
xSAB
X
X
X
X
(2)
X
X
X
X
L
H
H
xSBA
X
X
X
X
X
X
(2)
L
H
X
X
H
xAx
Input
Input
Input
Unspecified
(1)
Output
Output
Input
Output
Data I/O
(1)
xBx
Input
Unspecified
(1)
Output
Input
Input
Input
Output
Output
Operation or Function
Isolation
Store A and B Data
Store A, Hold B
Store A in Both Registers
Hold A, Store B
Store B in Both Registers
Real Time B Data to A Bus
Stored B Data to A Bus
Real Time A Data to B Bus
Stored A Data to B Bus
Stored A Data to B Bus and
Stored B Data to A Bus
NOTES:
1. The data output functions may be enabled or disabled by various signals at the xOEAB or xOEBA inputs. Data input functions are always enabled, i.e. data at the bus pins
will be stored on every LOW-to-HIGH transition on the clocks inputs.
2. Select control = L: clocks can occur simultaneously.
Select control = H: clocks must be staggered to load both registers.
3. H = HIGH Voltage Level
L = LOW Voltage Level
X = Don't care
↑
= LOW-to-HIGH Transition
3
IDT74FCT16652T/AT/CT
FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
INDUSTRIAL TEMPERATURE RANGE
BUS
A
BUS
B
BUS
A
BUS
B
x
OEAB
x
OEBA
x
CLKAB
x
CLKBA
x
SAB
x
SBA
x
OEAB
x
OEBA
x
CLKAB
x
CLKBA
x
SAB
x
SBA
L
L
X
X
X
L
H
H
X
X
L
X
Real-Time Transfer
Bus B to A
Real-Time Transfer
Bus A to B
BUS
A
BUS
B
BUS
A
BUS
B
x
OEAB
x
OEBA
x
CLKAB
x
CLKBA
x
SAB
x
SBA
x
OEAB
x
OEBA
x
CLKAB
x
CLKBA
x
SAB
x
SBA
X
L
L
H
X
H
↑
X
↑
↑
X
X
X
X
X
X
H
L
H or L
H or L
H
H
X
↑
Storage from
A and/or B
Transfer Stored
Data to A and/or B
4
IDT74FCT16652T/AT/CT
FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
INDUSTRIAL TEMPERATURE RANGE
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Industrial: T
A
= –40°C to +85°C, V
CC
= 5.0V ±10%
Symbol
V
IH
V
IL
I
IH
I
IL
I
OZH
I
OZL
V
IK
I
OS
V
H
I
CCL
I
CCH
I
CCZ
Parameter
Input HIGH Level
Input LOW Level
Input HIGH Current (Input pins)
(5)
Input HIGH Current (I/O pins)
(5)
Input LOW Current (Input pins)
(5)
Input LOW Current (I/O pins)
(5)
High Impedance Output Current
(3-State Output pins)
(5)
Clamp Diode Voltage
Short Circuit Current
Input Hysteresis
Quiescent Power Supply Current
V
CC
= Max
V
IN
= GND or V
CC
V
CC
= Min., I
IN
= –18mA
V
CC
= Max., V
O
= GND
(3)
—
V
CC
= Max.
V
O
= 2.7V
V
O
= 0.5V
V
I
= GND
Test Conditions
(1)
Guaranteed Logic HIGH Level
Guaranteed Logic LOW Level
V
CC
= Max.
V
I
= V
CC
Min.
2
—
—
—
—
—
—
—
—
–80
—
—
Typ.
(2)
—
—
—
—
—
—
—
—
–0.7
–140
100
5
Max.
—
0.8
±1
±1
±1
±1
±1
±1
–1.2
–250
—
500
V
mA
mV
µA
µA
Unit
V
V
µA
OUTPUT DRIVE CHARACTERISTICS
Symbol
I
O
V
OH
Parameter
Output Drive Current
Output HIGH Voltage
V
CC
= Min.
V
IN
= V
IH
or V
IL
V
OL
I
OFF
Output LOW Voltage
Input/Output Power Off Leakage
(5)
V
CC
= Min.
V
IN
= V
IH
or V
IL
V
CC
= 0V, V
IN
or V
O
≤
4.5V
—
—
±1
µA
NOTES:
1. For conditions shown as Min. or Max., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at V
CC
= 5.0V, +25°C ambient.
3. Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
4. Duration of the condition can not exceed one second.
5. This test limit for this parameter is ±5µA at T
Definition of interactive projection system:
Interactive projection systems, also known as multimedia interactive projection, are available in floor, wall, and tabletop interactive projection....[详细]