1.2.
1.3.
1.4.
1.5.
Type name:
Number of poles:
Operating temperature range:
Storage temperature range:
MQF 100.0-0400/06
2
-40°C to +105°C
-55°C to +125°C
2.
Electric values
fo:
fc at +25°C:
100.0 MHz
100.0 MHz
2.1. Nominal centre frequency
Center frequency
2.2.
Pass band
2.2.1. Pass band between 3 dB:
2.2.2. Ripple in pass band:
2.2.3. Insertion loss:
2.3. Stop band
1.5kHz
> fc 2.0 kHz
< 1.0 dB at fc 1.0 kHz
< 6.0 dB
2.3.1. fc 18 kHz
2.3.2. fc 33 kHz
2.3.3. Alternate attenuation at fo -910 kHz
> 15 dB
> 30 dB
> 30 dB except spurious
2.4. Terminating impedance R//C ( input and output ): 500
2.5. Maximum input power, working / non-damaged
// 0.8 pF
0 / +10 dBm
• M100A1
yyww
according to Vectron CF001
3.
Marking:
4.
Environment conditions:
5.
Packing
Drawing out direction
maximum 1000 pcs. / reel
Marking
Marking
Marking
Marking
Marking
Marking
Marking
Marking
Tape dimension ( mm )
Trailer
leader part ( 400mm min, )
cover tape
200mm min.
carrier tape
150mm min.
components placed
carrier tape
160mm min.
cover tape
240mm min.
Marking
Drawing out direction ( leading direction )
Tape ( all dimensions in mm )
P2
Marking
Marking
Marking
Marking
Marking
Marking
Marking
Marking
Marking
W: 16.0 ± 0.1
Po:
4.0 ± 0.1
P1:
8.0 ± 0.1
P2:
2.0 ± 0.1
Do:
1.5 +0.1 / -0
D1:
1.6 +0.1 / -0
E:
1.75 ± 0.1
F:
7.5 ± 0.1
Ko:
1.7 ± 0.1
Ao:
5.6 ± 0.1
Bo:
7.6 ± 0.1
t:
0.3 ± 0.05
P1
Po
t
D1
Do
E
F
W
Ao
Ko
Bo
W2
Reel ( all dimension in mm )
A:
C:
N:
W1:
W2:
ø 178 ± 2
ø 13 ± 0.5
ø 60 ± 1
17.5 ± 1.5
21.5 ± 1.5
C
N
A
W1
______________________________________________________________________
Edited by: