74AUP1G158
Rev. 6 — 26 October 2020
Low-power 2-input multiplexer; inverting
Product data sheet
1. General description
The 74AUP1G158 is a single 2-input inverting multiplexer. Schmitt-trigger action at all inputs
makes the circuit tolerant of slower input rise and fall times. This device ensures very low static
and dynamic power consumption across the entire V
CC
range from 0.8 V to 3.6 V. This device is
fully specified for partial power down applications using I
OFF
. The I
OFF
circuitry disables the output,
preventing the potentially damaging backflow current through the device when it is powered down.
2. Features and benefits
•
•
•
•
•
•
•
Wide supply voltage range from 0.8 V to 3.6 V
Overvoltage tolerant inputs to 3.6 V
Low static power consumption; I
CC
= 0.9 μA (maximum)
Latch-up performance exceeds 100 mA per JESD 78 Class II Level B
Low noise overshoot and undershoot < 10 % of V
CC
I
OFF
circuitry provides partial Power-down mode operation
Complies with JEDEC standards:
•
JESD8-12 (0.8 V to 1.3 V)
•
JESD8-11 (0.9 V to 1.65 V)
•
JESD8-7 (1.2 V to 1.95 V)
•
JESD8-5 (1.8 V to 2.7 V)
•
JESD8-B (2.7 V to 3.6 V)
ESD protection:
•
HBM JESD22-A114F Class 3A exceeds 5000 V
•
MM JESD22-A115-A exceeds 200 V
•
CDM JESD22-C101E exceeds 1000 V
Multiple package options
Specified from -40 °C to +85 °C and -40 °C to +125 °C
•
•
•
3. Ordering information
Table 1. Ordering information
Type number
Package
Temperature range
74AUP1G158GW
74AUP1G158GM
74AUP1G158GN
74AUP1G158GS
-40 °C to +125 °C
-40 °C to +125 °C
-40 °C to +125 °C
-40 °C to +125 °C
Name
SC-88
XSON6
XSON6
XSON6
Description
plastic surface-mounted package; 6 leads
Version
SOT363
plastic extremely thin small outline package; no leads; SOT886
6 terminals; body 1 × 1.45 × 0.5 mm
extremely thin small outline package; no leads;
6 terminals; body 0.9 × 1.0 × 0.35 mm
extremely thin small outline package; no leads;
6 terminals; body 1.0 × 1.0 × 0.35 mm
SOT1115
SOT1202
Nexperia
74AUP1G158
Low-power 2-input multiplexer; inverting
4. Marking
Table 2. Marking
Type number
74AUP1G158GW
74AUP1G158GM
74AUP1G158GN
74AUP1G158GS
[1]
Marking code
[1]
aU
aU
aU
aU
The pin 1 indicator is located on the lower left corner of the device, below the marking code.
5. Functional diagram
I1
1
6
4
Y
001aae018
I0
3
6
3
1
G1
1 MUX
1
S
4
001aae019
Fig. 1.
Logic symbol
1
3
SELECTOR
6
S
001aae020
Fig. 2.
IEC logic symbol
S
I1
I0
MULTIPLEXER
OUTPUTS
4
Y
I1
Y
I0
001aae021
Fig. 3.
Functional diagram
Fig. 4.
Logic diagram
6. Pinning information
6.1. Pinning
74AUP1G158
74AUP1G158
I1
GND
I0
1
2
3
001aae022
I1
1
6
S
I1
GND
74AUP1G158
1
2
3
6
5
4
S
V
CC
Y
6
5
4
S
V
CC
GND
2
5
V
CC
Y
I0
3
4
Y
I0
001aae023
001aae024
Transparent top view
Transparent top view
Fig. 5.
Pin configuration SOT363
(SC-88)
Fig. 6.
Pin configuration SOT886
(XSON6)
Fig. 7.
Pin configuration SOT1115
and SOT1202 (XSON6)
74AUP1G158
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2020. All rights reserved
Product data sheet
Rev. 6 — 26 October 2020
2 / 16
Nexperia
74AUP1G158
Low-power 2-input multiplexer; inverting
6.2. Pin description
Table 3. Pin description
Symbol
I1
GND
I0
Y
V
CC
S
Pin
1
2
3
4
5
6
Description
data input from source 1
ground (0 V)
data input from source 0
multiplexer output
supply voltage
common data select input
7. Functional description
Table 4. Function table
H = HIGH voltage level; L = LOW voltage level; X = don’t care.
Input
S
L
L
H
H
I1
X
X
L
H
I0
L
H
X
X
Output
Y
H
L
H
L
8. Limiting values
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
V
CC
I
IK
V
I
I
OK
V
O
I
O
I
CC
I
GND
T
stg
P
tot
[1]
[2]
Conditions
V
I
< 0 V
[1]
V
O
< 0 V
Active mode and Power-down mode
V
O
= 0 V to V
CC
[1]
Min
-0.5
-50
-0.5
-50
-0.5
-
-
-50
-65
Max
+4.6
-
+4.6
-
+4.6
±20
50
-
+150
250
Unit
V
mA
V
mA
V
mA
mA
mA
°C
mW
supply voltage
input clamping current
input voltage
output clamping current
output voltage
output current
supply current
ground current
storage temperature
total power dissipation
T
amb
= -40 °C to +125 °C
[2]
-
The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
For SOT363 (SC-88) package: P
tot
derates linearly with 3.7 mW/K above 83 °C.
For SOT886 (XSON6) package: P
tot
derates linearly with 3.3 mW/K above 74 °C.
For SOT1115 (XSON6) package: P
tot
derates linearly with 3.2 mW/K above 71 °C.
For SOT1202 (XSON6) package: P
tot
derates linearly with 3.3 mW/K above 74 °C.
74AUP1G158
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2020. All rights reserved
Product data sheet
Rev. 6 — 26 October 2020
3 / 16
Nexperia
74AUP1G158
Low-power 2-input multiplexer; inverting
9. Recommended operating conditions
Table 6. Recommended operating conditions
Symbol Parameter
Conditions
V
CC
V
I
V
O
T
amb
Δt/ΔV
supply voltage
input voltage
output voltage
ambient temperature
input transition rise and fall rate
V
CC
= 0.8 V to 3.6 V
Active mode
Power-down mode; V
CC
= 0 V
Min
0.8
0
0
0
-40
0
Max
3.6
3.6
V
CC
3.6
+125
200
Unit
V
V
V
V
°C
ns/V
10. Static characteristics
Table 7. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
T
amb
= 25 °C
V
IH
HIGH-level input voltage
V
CC
= 0.8 V
V
CC
= 0.9 V to 1.95 V
V
CC
= 2.3 V to 2.7 V
V
CC
= 3.0 V to 3.6 V
V
IL
LOW-level input voltage
V
CC
= 0.8 V
V
CC
= 0.9 V to 1.95 V
V
CC
= 2.3 V to 2.7 V
V
CC
= 3.0 V to 3.6 V
V
OH
HIGH-level output voltage
V
I
= V
IH
or V
IL
I
O
= -20 μA; V
CC
= 0.8 V to 3.6 V
I
O
= -1.1 mA; V
CC
= 1.1 V
I
O
= -1.7 mA; V
CC
= 1.4 V
I
O
= -1.9 mA; V
CC
= 1.65 V
I
O
= -2.3 mA; V
CC
= 2.3 V
I
O
= -3.1 mA; V
CC
= 2.3 V
I
O
= -2.7 mA; V
CC
= 3.0 V
I
O
= -4.0 mA; V
CC
= 3.0 V
V
OL
LOW-level output voltage
V
I
= V
IH
or V
IL
I
O
= 20 μA; V
CC
= 0.8 V to 3.6 V
I
O
= 1.1 mA; V
CC
= 1.1 V
I
O
= 1.7 mA; V
CC
= 1.4 V
I
O
= 1.9 mA; V
CC
= 1.65 V
I
O
= 2.3 mA; V
CC
= 2.3 V
I
O
= 3.1 mA; V
CC
= 2.3 V
I
O
= 2.7 mA; V
CC
= 3.0 V
I
O
= 4.0 mA; V
CC
= 3.0 V
I
I
I
OFF
input leakage current
power-off leakage current
V
I
= GND to 3.6 V; V
CC
= 0 V to 3.6 V
V
I
or V
O
= 0 V to 3.6 V; V
CC
= 0 V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.1
0.31
0.31
0.31
0.44
0.31
0.44
±0.1
±0.2
V
V
V
V
V
V
V
μA
μA
0.3 × V
CC
V
V
CC
- 0.1
0.75 × V
CC
1.11
1.32
2.05
1.9
2.72
2.6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V
V
V
V
V
V
V
V
0.70 × V
CC
0.65 × V
CC
1.6
2.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V
V
V
V
Conditions
Min
Typ
Max
Unit
0.30 × V
CC
V
0.35 × V
CC
V
0.7
0.9
V
V
74AUP1G158
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2020. All rights reserved
Product data sheet
Rev. 6 — 26 October 2020
4 / 16
Nexperia
74AUP1G158
Low-power 2-input multiplexer; inverting
Conditions
Min
-
-
-
-
-
0.70 × V
CC
0.65 × V
CC
1.6
2.0
-
-
-
-
V
CC
- 0.1
0.7 × V
CC
1.03
1.30
1.97
1.85
2.67
2.55
-
-
-
-
-
-
-
-
-
-
-
-
-
Typ
-
-
-
0.8
1.7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Max
±0.2
0.5
40
-
-
-
-
-
-
Unit
μA
μA
μA
pF
pF
V
V
V
V
Symbol Parameter
ΔI
OFF
I
CC
ΔI
CC
C
I
C
O
V
IH
additional power-off leakage V
I
or V
O
= 0 V to 3.6 V;
current
V
CC
= 0 V to 0.2 V
supply current
additional supply current
input capacitance
output capacitance
HIGH-level input voltage
V
I
= GND or V
CC
; I
O
= 0 A;
V
CC
= 0.8 V to 3.6 V
V
I
= V
CC
- 0.6 V; I
O
= 0 A; V
CC
= 3.3 V
[1]
V
CC
= 0 V to 3.6 V; V
I
= GND or V
CC
V
O
= GND; V
CC
= 0 V
V
CC
= 0.8 V
V
CC
= 0.9 V to 1.95 V
V
CC
= 2.3 V to 2.7 V
V
CC
= 3.0 V to 3.6 V
T
amb
= -40 °C to +85 °C
V
IL
LOW-level input voltage
V
CC
= 0.8 V
V
CC
= 0.9 V to 1.95 V
V
CC
= 2.3 V to 2.7 V
V
CC
= 3.0 V to 3.6 V
0.30 × V
CC
V
0.35 × V
CC
V
0.7
0.9
-
-
-
-
-
-
-
-
0.1
0.37
0.35
0.33
0.45
0.33
0.45
±0.5
±0.5
±0.6
0.9
50
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
μA
μA
μA
μA
μA
V
OH
HIGH-level output voltage
V
I
= V
IH
or V
IL
I
O
= -20 μA; V
CC
= 0.8 V to 3.6 V
I
O
= -1.1 mA; V
CC
= 1.1 V
I
O
= -1.7 mA; V
CC
= 1.4 V
I
O
= -1.9 mA; V
CC
= 1.65 V
I
O
= -2.3 mA; V
CC
= 2.3 V
I
O
= -3.1 mA; V
CC
= 2.3 V
I
O
= -2.7 mA; V
CC
= 3.0 V
I
O
= -4.0 mA; V
CC
= 3.0 V
V
OL
LOW-level output voltage
V
I
= V
IH
or V
IL
I
O
= 20 μA; V
CC
= 0.8 V to 3.6 V
I
O
= 1.1 mA; V
CC
= 1.1 V
I
O
= 1.7 mA; V
CC
= 1.4 V
I
O
= 1.9 mA; V
CC
= 1.65 V
I
O
= 2.3 mA; V
CC
= 2.3 V
I
O
= 3.1 mA; V
CC
= 2.3 V
I
O
= 2.7 mA; V
CC
= 3.0 V
I
O
= 4.0 mA; V
CC
= 3.0 V
0.3 × V
CC
V
I
I
I
OFF
ΔI
OFF
I
CC
ΔI
CC
input leakage current
power-off leakage current
V
I
= GND to 3.6 V; V
CC
= 0 V to 3.6 V
V
I
or V
O
= 0 V to 3.6 V; V
CC
= 0 V
additional power-off leakage V
I
or V
O
= 0 V to 3.6 V;
current
V
CC
= 0 V to 0.2 V
supply current
additional supply current
V
I
= GND or V
CC
; I
O
= 0 A;
V
CC
= 0.8 V to 3.6 V
V
I
= V
CC
- 0.6 V; I
O
= 0 A; V
CC
= 3.3 V
[1]
74AUP1G158
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2020. All rights reserved
Product data sheet
Rev. 6 — 26 October 2020