CT1990/1 Series
MIL-STD-1553B Remote Terminal, BUS Controller,
or Passive Monitor Hybrid with Status Word Control
www.aeroflex.com/Avionics
June 13, 2005
FEATURES
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
Performs the Complete Dual-Redundant Remote Terminal, Bus Controller Protocol and Passive Monitor Functions of MIL-STD-1553B
Automated Self-Test Functions
Allows Setting of the Message Error Bit on Illegal Commands
Provides Programmable Control over Terminal Flag and Subsystem Flag Status Bits
50mW Typical Power Consumption
+5V DC Operation
Full Military (-55°C to +125°C) Temperature Range
Advanced Low Power VLSI Technology
Compatible with all Aeroflex-Plainview Driver/Receiver Units
Designed for Commercial, Industrial and Aerospace Applications
MIL-PRF-38534 compliant devices available
Aeroflex-Plainview is a Class H & K MIL-PRF-38534 Manufacturer
Packaging – Hermetic Ceramic Plug-In - 90 Pin, 2.4"L x 1.6"W x .225"Ht
DESC SMD# 5962–94775: Released CT1990, Pending CT1991
Encoder
Interface
Unit
Sub Address
&
Word Count
Outputs
ASIC
Decoder
"O"
Driver
Select
&
Enable
Decoder
"1"
BUS "0"
T/R
Hybrid
Status
Word
Control
Program
Inputs
Discrete
Outputs
ASIC
BUS "1"
T/R
Hybrid
Internal
Highway
Control
Control
Inputs
Terminal
Address
Inputs
CT1990/1
Figure 1 – BLOCK DIAGRAM (WITH TRANSFORMERS)
DESCRIPTION
The Aeroflex-Plainview CT1990/1 Series is a monolithic implementation of the MIL-STD-1553B Bus Controller,
Remote Terminal and Passive Monitor functions. All protocol functions of MIL-STD-1553B are incorporated and
a number of options are included to improve flexibility. These features include programming of the status word,
illegalizing specific commands and an independent loop back self-test which is initiated by the subsystem. This
unit is directly compatible with all microprocessor interfaces such as the CT1611 and CT1800 produced by
Aeroflex.
SCDCT1990 Rev C
ABSOLUTE MAXIMUM RATINGS
Parameter
V
CC
Input or Output Voltage at any Pin
Storage Case Temperature
Load Temperature (Soldering 10 Sec)
Min
-0.3
-0.3
-65
-
Max
7.0
V
CC
+ 0.3V
+150
+300
Units
V
V
°C
°C
RECOMMENDED DC OPERATING CONDITIONS
Parameter
V
CC
(Logic)
V
IH
V
IL
V
CC
= 5.0V
V
CC
= 5.0V
Test Conditions
Min
4.5
2.2
-
Typ
5.0
-
-
Max
5.5
-
0.7
Unit
V
V
V
Notes
-
1,2
1,2
ELECTRICAL CHARACTERISTICS
(T
A
= -55°C to +125°C)
Parameter
V
OH
High Level Output Voltage
V
OL
Low Level Output Voltage
I
IH
High Level Input Current
I
IL
Low Level Input Current
I
CC
Supply Current
Test Conditions
V
CC
= 4.5V
V
CC
= 4.5V
V
CC
= 5.5V,
V
IN
= 2.7V
V
CC
= 5.5V,
V
IN
= 0.4V
V
CC
= 5.5V
Min
2.4
-
-200
-25
-400
-25
-
Typ
-
-
-
-
-
-
-
Max
-
0.4
-700
-400
-900
-400
20
Unit
V
V
µA
µA
µA
µA
mA
Notes
4
4
2
3
2
3
4
NOTES:
1/ RTAD 0/1/2/3/4 and RTADPAR ONLY.
2/ ALL Inputs and Bidirectionals other than those in Note 1.
3/ I
OL
max = 3mA / I
OH
max = -2mA TX INHIBIT 0/1 and TX DATA/DATA ONLY.
I
OL
max = 2mA / I
OH
max = -1mA – ALL remaining Outputs and Bidirectionals.
4/ Input Clock (running) = 6MHz, ALL remaining Inputs are Open and ALL Outputs and Bidirectionals have no load
CLOCK REQUIREMENTS
Parameter
Frequency:
Stability -55°C to +125°C:
Maximum Asymmetry:
Rise/Fall Time:
Output Level:
Range
6.0 MHz
±0.01% (100ppm)
48 - 52%
10ns MAX
Logic "0" 0.4V MAX
Logic "1" 2.4V MIN
SCDCT1990 Rev C
2
REMOTE TERMINAL OPERATION
Receive Data Operation
All valid data words associated with a valid receive data command word for the RT are passed to the subsystem.
The RT examines all command words from the bus and will respond to valid (i.e. correct Manchester, parity
coding etc.) commands which have the correct RT address (or broadcast address if the RT broadcast option is
enabled). When the data words are received, they are decoded and checked by the RT and, if valid, passed to the
subsystem on a word by word basis at 20µs intervals. This applies to receive data words in both Bus Controller to
RT and RT to RT messages. When the RT detects that the message has finished, it checks that the correct number
of words have been received and if the message is fully valid, then a Good Block Received signal is sent to the
subsystem, which must be used by the subsystem as permission to use the data just received.
The subsystem must therefore have a temporary buffer store up to 32 words long into which these data words can
be placed. The Good Block Received signal will allow use of the buffer store data once the message has been
validated.
If a block of data is not validated, then Good Block Received will not be generated. This may be caused by any
sort of message error or by a new valid command for the RT being received on another bus to which the RT must
switch.
Transmit Data Operation
If the RT receives a valid transmit data command addressed to the RT, then the RT will request the data words
from the subsystem for transmission on a word by word basis. To allow maximum time for the subsystem to
collect each data word, the next word is requested by the RT as soon as the transmission of the current word has
commenced.
It is essential that the subsystem should provide all the data words requested by the RT once a transmit sequence
has been accepted. Failure to do so will be classed by the RT as a subsystem failure and reported as such to the Bus
Controller.
Control of Data Transfers
This section describes the detailed operation of the data transfer mechanism between the RT and subsystems. It
covers the operations of the signals DTRQ, DTAK, IUSTB, H/L, GBR, NBGT, TX/RX during receive data and
transmit data transfers.
Figure 7 shows the operation of the data handshaking signals during a receive command with two data words.
When the RT has fully checked the command word, NBGT is pulsed low, which can be used by the subsystem as
an initialization signal. TX/RX will be set low indicating a receive command. When the first data word has been
fully validated, DTRQ is set low. The subsystem must then reply within approximately 1.5µs by setting DTAK
low. This indicates to the RT that the subsystem is ready to accept data. The data word is then passed to the
subsystem on the internal highway IH08-IH715 in two bytes using IUSTB as a strobe signal and H/L as the byte
indicator (high byte first followed by low byte). Data is valid about both edges of IUSTB. Signal timing for this
handshaking is shown in Figure 12.
If the subsystem does not declare itself busy, then it must respond to DTRQ going low by setting DTAK low
within approximately 1.5µs. Failure to do so will be classed by the RT as a subsystem failure and reported as such
to the Bus Controller.
It should be noted that IUSTB is also used for internal working in the RT. DTRQ being low should be used as an
enable for clocking data to the subsystem with IUSTB.
Once the receive data block has finished and been checked by the RT, GBR is pulsed low if the block is entirely
correct and valid. This is used by the subsystem as permission to make use of the data block. If no GBR signal is
generated, then an error has been detected by the RT and the entire data block is invalid and no data words in it
may be used.
SCDCT1990 Rev C
3
If the RT is receiving data in an RT to RT transfer, the data handshaking signals will operate in an identical fashion
but there will be a delay of approx 70µs between NBGT going low and DTRQ first going low. See Figure 10.
Figure 6 shows the operation of the data handshaking signals during transmit command with three data words. As
with the receive command discussed previously, NBGT is pulsed low if the command is valid and for the RT.
TX/RX will be set high indicating a transmit data command. While the RT is transmitting its status word, it
requests the first data word from the subsystem by setting DTRQ low. The subsystem must then reply within
approximately 13.5µs by setting DTAK low. By setting DTAK low, the subsystem is indicating that it has the data
word ready to pass to the RT. Once DTAK is set low by the subsystem, DTRQ should be used together with H/L
and TX/RX to enable first the high byte and then the low byte of the data word onto the internal highway
IH08-IH715. The RT will latch the data bytes during IUSTB, and will then return DTRQ high. Data for each byte
must remain stable until IUSTB has returned low. Signal timing for this handshaking is shown in Figure 11.
Additional Data Information Signals
At the same time as data transfers take place, a number of information signals are made available to the
subsystem. These are INCMD, the subaddress lines SA0-SA4, the word count lines WC0-WC4 and current word
count lines CWC0-CWC4. Use of these signals is optional.
INCMD will go active low while the RT is servicing a valid command for the RT. The subaddress,
transmit/receive bit, and word count from the command word are all made available to the subsystem as
SA0-SA4, TX/RX and WC0-WC4 respectively. They may be sampled when INCMD goes low and will remain
valid while INCMD is low.
The subaddress is intended to be used by the subsystem as an address pointer for the data block. Subaddress 0 and
31 are mode commands, and there can be no receive or transmit data blocks associated with these. (Any data word
associated with a mode command uses different handshaking operations. If the subsystem does not use all the
subaddresses available, then some of the subaddress lines may be ignored.
The TX/RX signal indicates the direction of data transfer across the RT - subsystem interface. Its use is described
in the previous section.
The word count tells the subsystem the number of words to expect to receive or transmit in a message, up to 32
words. A word count of all 0s indicates a count of 32 words.
The current word count is set to 0 at the beginning of a new message and is incremented following each data word
transfer across the RT - subsystem interface. (It is clocked on the falling edge of the second IUSTB pulse in each
word transfer). It should be noted that there is no need for the subsystem to compare the word count and current
word count to validate the number of words in a message. This is done by the RT.
SUBSYSTEM USE OF STATUS BITS AND MODE COMMANDS
General Description
Use of the status bits and the mode commands is one of the most confusing aspects of MIL-STD-1553B. This is