SPECIFICATION SHEET
JFW MODEL 50PA-389
HANDOVER TEST SYSTEM
JFW Industries, Inc.
Phone: 317-887-1340
sales@jfwindustries.com
www.jfwindustries.com
Frequency Range
Configuration
Impedance
VSWR
Insertion Loss
Attenuation Range
Attenuation Accuracy
(guaranteed monotonic)
Power Divider Isolation
RF Input Power
Switching Speed
800-3000 MHz
12 x 4 Handover Test System
See block diagram 092-5634
50 Ohms nominal
1.5:1 typical
1.7:1 maximum
29.2 dB typical @ 800 MHz
33.7 dB typical @ 3000 MHz
0-127 dB in 1 dB steps
± 0.5 dB or 2% (typical)
± 0.75 dB or 2% (maximum)
20 dB minimum
+25 dBm operating
+30 dBm (no damage)
10 microseconds typical
(after command is received and processed)
(3 milliseconds typical processing time)
100-240 VAC @ 47-63 Hz
Keypad and LCD display
Ethernet (10/100) and RS-232
Set Attenuator
Read Attenuator
Fade Attenuator
Handover
Variable Handover
Change Baud Rate
(SAx y <CR>)
(RAx <CR>)
(FAx y z t <CR>)
(HNDx y t)
(VHND Av Aw Vx Vy Tz)
(CBx <CR>)
AC Supply
Manual Control
Remote Control
Remote Commands
Baud Rates (RS-232 mode)
RF Connector
Temperature Range
Physical Size
9600, 19200, or 38400 Baud
SMA female
0ºC to +50ºC
See outline drawing 092-5635
--CONTINUED--
Page 1 of 2
JFW FORM E-7-F REV F