电子工程世界电子工程世界电子工程世界

关键词

搜索

型号

搜索

PVQ-EUSDC1MRD

产品描述Cable Assembly
产品类别连接器    连接器支架   
文件大小102KB,共2页
制造商Panduit
官网地址http://www.panduit.com
标准
下载文档 详细参数 选型对比 全文预览

PVQ-EUSDC1MRD在线购买

供应商 器件名称 价格 最低购买 库存  
PVQ-EUSDC1MRD - - 点击查看 点击购买

PVQ-EUSDC1MRD概述

Cable Assembly

PVQ-EUSDC1MRD规格参数

参数名称属性值
是否Rohs认证符合
Reach Compliance Codecompli
Factory Lead Time12 weeks
连接器支架类型CABLE ASSEMBLY
Base Number Matches1

文档预览

下载PDF文档
PanView iQ
(PViQ
) Interconnect
Patch Cords – Enhanced
specifications
Category 6A/Class E
A
UTP interconnect patch cords shall be constructed
of 26 AWG stranded copper cable with a PViQ
Patch Panel Plug on one
end and a LED switch modular plug on the other end. Copper conductors
in patch cable shall be twisted in pairs and separated by a quadrant
separator. All four pairs shall be surrounded by MaTriX tape. Additional
26 AWG conductors shall connect the LED switch plug to 9th and 10th
contacts on the PViQ
Patch Panel Plug. A flame retardant jacket will
cover all conductors. The MaTriX tape shall suppress alien crosstalk and
allow 10 Gb/s transmission. Patch cords shall be used in conjunction with
intelligent patch panels and exclusively for interconnect architectures.
S P E C I F I C AT I O N S H E E T
PanView iQ
Interconnect Patch Cords –
Enhanced – UTP CM Rated
Foot lengths:
PVQ-EUSDC3BU*
Meter lengths:
PVQ-EUSDC1MBU^
PanView iQ Interconnect Patch Cords –
Enhanced – STP CM/LSZH Rated
Foot lengths:
PVQ-ES6X3BU*
Meter lengths:
PVQ-ES6X1MBU^
PanView iQ
Interconnect Patch
Cords – CM Rated
Foot lengths:
PVQ-BIU6C3BU*
Meter lengths:
PVQ-BIU6C1MBU**
PanView iQ Interconnect Patch
Cords – LSZH Rated
Meter lengths:
PVQ-BIU6L1MBU^
PanView iQ
Patch Panels
Modular, intelligent, blank 24-port
Flat unshielded:
PVQ-MIQPU24
Angled unshielded:
PVQ-MIQAPU24
Flat shielded:
PVQ-MIQPS24
Angled shielded:
PVQ-MIQAPS24
PanView iQ
Intelligence Modules
Panel manager (PM):
PVQ-PM
Expansion module
(EM):
PVQ-EM
NOTE: PM requires PanViewiQ
Power Supply
(not included).
PanView iQ
Power Supply
12 volt power supply
(North America):
PVQ-PS12VDC-S
(Europe):
PVQ-PS12VDC-E
(UK):
PVQ-PS12VDC-U
(Japan):
PVQ-PS12VDC-J
(China):
PVQ-PS12VDC-C
PIM
Software Platform and Modules
Base functionality
module:
PIM-BASE
Connectivity management
module:
PIM-CONNECT‡
Maintenance, support and warranty
agreement:
PIM-CAMA
*For standard lengths other than 3 feet (5, 7, 10,
14, or 20) change the length designation in the
part number to the desired length. For standard
cable color other than BU (Blue), replace suffix
BU with WH (White) at the end of the part number.
For example, the part number for a white, 5-foot
UTP patch cord is PVQ-EUSDC5WH. For example,
the part number for a white, 5-foot STP patch
cord is PVQ-ES6X5WH.
^For standard lengths other than 1 meter (2, 3,
5 or 10) change the length designation in the part
number to the desired length. For standard cable
color other than BU (Blue), replace suffix BU with
WH (White) at the end of the part number. For
example, the part number for a white 2 meter
UTP patch cord is PVQ-ES6X2MWH. For example,
the part number for a white 2 meter STP patch
cord is PVQ-ES6X2MWH.
**For standard lengths other than 3 feet (5, 7, 10,
14, or 20) change the length designation in part
number to the desired length. For standard cable
colors other than BU (Blue) replace suffix BU with
GR (Green) at the end of the part number. For
example, the part number for a green 10-foot
CM patch cord is PVQ-BIU6C10GR.
***For standard lengths other than 1 meter (2, 3,
5, or 10) change the length designation in part
number to the desired length. For standard cable
colors other than BU (Blue) replace suffix BU with
GR (Green) at the end of the part number. For
example, the part number for a green 10-meter
CM patch cord is PVQ-BIU6C10MGR.
^^For standard lengths other than 1 meter (2, 3,
5, or 10) change the length designation in part
number to the desired length. For standard cable
colors other than BU (Blue), replace suffix BU
with WH (White) at the end of the part number.
For example, the part number for a white 10-meter,
LSZH patch cord is PVQ-BIU6L10MWH.
‡To order this module, add the appropriate letter
to the end of the part number, based on the size
of the installation: -S (<50 racks); -M (50-199
racks); -L (200-399 racks); -X (400+ racks). For
example, the part number for the Connectivity
Management Module for 250 racks
is PIM-CONNECT-L.
technical information
Category 6A/Class E
A
channel performance:
Certified channel performance in a 4-connector configuration up to 100
meters and exceeds the requirements of ANSI/TIA-568-C.2 Category
6A and ISO 11801 Class E
A
standards for supporting 10GBASE-T
transmission over twisted-pair cabling systems; attenuation de-rating
factor is 1.5
Certified component performance to the ANSI/TIA-568-C.2 component
standard for supporting 10GBASE-T transmission over twisted-pair
cabling systems
Cable diameter:
Temperature rating:
FCC and ANSI compliance:
IEC compliance:
PoE compliance:
UL listed:
0.255 in. (6.5mm) nominal
14°F to 140°F (-10°C to 60°C) during operation
-40°F to 158°F (-40°C to 70°C) during storage
Meets ANSI/TIA/EIA-1096-A; contacts plated with 50 microinches of
gold for superior performance
Meets IEC 60603-7
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications
UL 1863
key features and benefits
Switch/server
port detection
100% performance tested
Integral pair manager
Slender strain relief boot
Patented tangle free latch
Ninth conductor continuity
Communicates connection status between switch/server and PViQ
Patch Panels
Assurance that each patch cord will deliver the critical
electrical performance requirements
Optimizes performance and consistency by reducing untwist at the plug
Provides easy access in high-density applications
Prevents snags and provides easy release, saving time on frequent
moves, adds, and changes
Provides continuity through the patch cord enabling the PanView iQ
System to monitor connectivity without interfering with
Ethernet performance
Meets individual length and color-coding requirements for greater
system flexibility
LEDs aid in patch cord tracing and connectivity changes at the switch
end; they also identify unauthorized removals or insertions
Variety of cable colors
and lengths
LED indicator and switch
applications
Panduit’s PViQ
System Hardware, which
includes intelligent patch panels, modules and
cabling, seamlessly feeds information directly
into the Physical Infrastructure Manager (PIM
)
Software Platform to provide continuous real-time
patch field monitoring and visibility of physical
infrastructure connectivity for enhanced system
reliability, security and capacity management.
PViQ
Patch Panels support tiered installations to
provide customers with the flexibility of installing
passive connectivity that may be upgraded to fully
managed at a future time. PViQ
Interconnect Patch
Cords enable intelligent physical infrastructure
management for interconnect architectures by
verifying switch port connection and communicating
with the system software, to allow improved network
visibility. Interconnect patch cords can reduce patch
panel requirements by 50% over cross-connect
designs, reducing installation and deployment costs.
w w w.pand uit.co m

PVQ-EUSDC1MRD相似产品对比

PVQ-EUSDC1MRD PVQ-EUSDC1MBU PVQ-EUSDC14GR PVQ-EUSDC2MYL PVQ-EUSDC3MBU PVQ-EUSDC2MRD PVQ-EUSDC1MYL PVQ-EUSDC7RD PVQ-EUSDC2MGR
描述 Cable Assembly Cable Assembly Cable Assembly Cable Assembly Cable Assembly Cable Assembly Cable Assembly Cable Assembly Cable Assembly
是否Rohs认证 符合 符合 符合 符合 符合 符合 符合 符合 符合
Reach Compliance Code compli compli compli compli compliant compliant compliant compliant compli
Factory Lead Time 12 weeks 12 weeks 12 weeks 12 weeks 12 weeks 12 weeks 12 weeks 12 weeks 12 weeks
连接器支架类型 CABLE ASSEMBLY CABLE ASSEMBLY CABLE ASSEMBLY CABLE ASSEMBLY CABLE ASSEMBLY CABLE ASSEMBLY CABLE ASSEMBLY CABLE ASSEMBLY CABLE ASSEMBLY
Base Number Matches 1 1 1 1 1 1 1 1 -
红外传感器在障碍物探测应用中的抗干扰问题
避开环境红外光频率确定红外传感器接收器中带通滤波器的中心频率 根据带通滤波器中心频率选择发射 #器的发射频率 根据接收器响应时间选择发射器发射的红外光的调制频率 采用左右发射管轮流发光 ......
frozenviolet 机器人开发
ATX电源供应器
我的350W电源的一个保险管熔断了(F2保险管,3A),现在临时找了同型号电源的一个4A保险管换上,是否可行...
HAMSAM 模拟与混合信号
USB-Blaster ep2c35
请教各位前辈 用USB-Blaster 能读出ep2c35内的程序吗 小弟是纯菜鸟 在此多谢啦...
xxytx FPGA/CPLD
用netlink进行内核空间向用户空间传送数据时的问题!
大家好,在用netlink进行内核空间向用户空间传送数据时,用户空间有反应但一直没有接到实际的数据(rcvlen一直等于15(也就是getbuf数据的大小,可是getbuf一直为空))。由此看来内核空间和用户 ......
danglingbo 嵌入式系统
]高品质的LED有五大特点
高品质的LED有五大特点: 1. 失效率:在LED显示屏开始装配至老化72小时的失效率不高于万分之一2. 抗静电能力:LED的人体静电模式测试失效电压不低于3000V3. 衰减特性:1000小时,20毫安常温点亮 ......
探路者 LED专区
[BB方案]第二辑——Linux的设备驱动
再次拜读了楼主的作品,于是就更加认为楼主是个山炮。 ——又是楼主 在Linux领域,可能再也找不到比楼主还矬的开发者了。 ......
sjtitr DSP 与 ARM 处理器

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1615  2800  1410  1067  2679  33  57  29  22  54 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved