The JDSU SN Series fiberoptic switch is GR-1221 qualified and designed for use
in central office network applications. This reliable, miniature optical component
is available as a 1x1 (on/off), 1x2, and 2x2 switch.
Collimated lenses and a moving mirror minimize insertion loss and improve the
repeatability and stability of the switch parameters. The switch itself is directly
mounted on printed circuit boards (PCBs), and is equipped with status contacts
to provide an electrical readout of the switch position. Latching operation ensures
that the switch remains in position following power loss.
On request, JDSU also provides customized modular assemblies that incorporate
taps, wavelength division multiplexers (WDMs), splitters, and other components.
Compliance
• Telcordia GR-1221-CORE and
GR-1073-CORE
NORTH AMERICA
:
800 498-JDSU (5378)
WORLDWIDE
:
+800 5378-JDSU
WEBSITE
:
www.jdsu.com
SN SERIES FIBEROPTIC SWITCH
2
SN Series Dimensions Diagram
1.904 [48.36]
.714 [18.14]
.349 [8.86]
.230 [5.84]
.100 [2.54]
.730 [18.54]
1.855 [47.12]
.125 [3.18]
.135 [3.43]
.105 [2.67]
.405 [10.29]
.505 [12.83]
.29 [7.4]
.50 [12.7]
Pin #12
.000 [.00]
Pin #1
.300 [7.62]
.400 [10.16]
Ø .040 [1.02]
11 PL
Pin #6
(Specifications in inches [mm] unless otherwise noted.)
.167 [4.24]
1.625 [41.28]
.000 [.00]
.100 [2.54]
.200 [5.08]
.400 [10.16]
.500 [12.70]
PCB
NOTES: RECOMMENDED BOARD THICKNESS .063" [1.59]
SWITCH MOUNTING HOLE PATTERN
Specifications
Parameter
Wavelength range
Insertion loss
1
1x1, 1x2
2x2
Return loss
2
Polarization dependent loss
2
Repeatability
Crosstalk
Optical input power (continuous wave)
Switching time
Cycle rate
Power supply
3
Dimensions (W x H x D)
Weight
Operating temperature
Storage temperature
Humidity (non-condensing)
Qualification
Specification
1290 to 1330 and/or 1525 to 1610 nm
0.8 dB
1.0 dB
55 dB
0.1 dB
±0.05 dB
-60 dB
300 mW
9 ms
10 Hz
5 V DC/40 mA ±10%
48.4 x 8.7 x 18.1 mm
14 g
0 to 65 °C, or -5 to 70 °C short term
4
-40 to 85 °C
<85% RH, or 90% RH short term
4
GR-1221-CORE, GR-1073-CORE
1. Insertion loss is specified for the 1290 to 1330 nm and 1520 to 1570 nm wavelength ranges, all polarization states, and does not include connectors. Add 0.3 dB maximum
over operating temperature range. Add 0.1 dB maximum for extended wavelength operation up to 1610 nm.
2. Excluding connectors.
3. A 5 V DC 40 mA pulse of 20 ms duration is recommended.
4. The switch can be operated over the short term from -5 to 70 °C for 96 consecutive hours or less and a total of 15 days or less over a one year period.
SN SERIES FIBEROPTIC SWITCH
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at
customer.service@jdsu.com.
Sample: SN22+10750FA
SN
Code
11
12
22
+1
Configuration
1x1
1x2 (2x1)
2x2
Code
2
7
Fiber Type
9/125/250 µm
1
9/125/900 µm
Code
1
3
5
D
W
Wavelength
1525
to
1610
nm
1290
to
1330
nm
1525
to
1575
nm
1290
to
1330
nm
and
1525
to
1575
nm
1290
to
1330
nm
and 1525
to
1610
nm
Code
NC
FA
FP
LC
SC
SP
SU
MU
Connector Type
No
connector
FC/APC
FC/HPC
LC/PC
SC/HPC
ST/HPC
SC/APC
MU
Code
0
Control Type
Direct
control
Code
0
5
Fiber Length
1.0 m
1.5 m
1. The 250 µm fiber option is only available with the “no connector” option.
SynQor推出超小的病人全接触型400W医疗电源模块,该电源模块的封装为3×5×1.44,功率密度高达18.3W/立方英寸,转换效率达91%。 SynQor通过推出首款专门针对医疗应用而研制的AC/DC电源模块,使得公司的多元化战略持续成功地延伸至新的医疗领域。ACuQor模块系列实现了在3×5×1.44有限尺寸上提供400W的有用功率。SynQor可以提供48V,36V or 24V的...[详细]
便携式医疗设备的特殊性决定了它们应该是对用户友好的、必须工作在无菌环境下,并且空间占用小、耗能低。 同时,便携式医疗设备还需要足够的计算能力以便处理医疗数据,能够连接到无线或有线接口以便记录和发送数据。从设计人员的角度考虑,上述需求需要低功耗的单片机(MCU)和数字信号控制器(Digital Signal Controller,DSC)。 正是有了嵌入式处理器,设计人员才有可能设...[详细]