SA01
FEATURES
Series
5~7.5 Watts
Switching Adapter
●Cispr
22’B’, Vcci’B’, Fcc’B’ Compliance
●Light
Weight: 110g only
●Efficiency
62%~74%
●Over-Voltage
Protective Installation
●Short-circuit
Protective Installation
●Protection
Type: Auto-Recover
●Operating
Temperature 0℃~40℃
SPECIFICATION
Model
Item
Output Voltage
Output Rating
Input Voltage
Input Frequency
Input Current
Inrush Current
Line Regulation
Load Regulation
Ripple & Noise
Efficiency
Temperature Coefficient
Over-Voltage Protection
Operating Temperature
Storage Temperature
Fig. A
8V~14V Maximum
SA0104~07 SA013V3
+4V~7V
6W Max
+3.3V
1.5A
SA0105
+5V
1.4A
SA0106
+6V
1.2A
SA0109
+9V
0.8A
SA0112
+12V
0.6A
AC 90~264V
47~63Hz
0.3A Maximum
30A Maximum
2% Maximum
±
5%
1% Maximum
67% Typical
62% Typical
67% Typical
69% Typical
72% Typical
74% Typical
0.05%/℃
7V Maximum
10V Maximum
12V Maximum
18V Maximum
24V Maximum
0~40℃
-20~85℃
UL, CUL, CB, LPS, CE, BSMI, PSE
CE
LPS, CE, BSMI
BSI, LPS, CE, BSMI
TUV, CB, LPS, CE, BSMI
Safety Description
Fig. B
Fig. C
Fig. D
(*): Under Development
(I/P): In Process
Bothhand USA
e-mail: sales@bothhandusa.com
http://www.bothhand.com
462 Boston St - Topsfield, MA 01983 - Phone: 978-887-8050 - Fax: 978-887-5434
ORDERING INFORMATION
SA01 0 5 - A - 1 A
Output plug List
Mechanical
Output Voltage
MECHANICAL
Fig. A
Fig. C
Fig. B
Fig. D
Unit: m.m.
Standard Output Cable:
3.3V: 18AWG, UL SPT-1, 1800mm.
4V~12V: 20AWG, UL 2468, 1800mm.
<
Bothhand USA.
e-mail: sales@bothhandusa.com http://www.bothhand.com