Compact High Voltage Power Supply Units C4710 Series
The C4710 series comprises on-board type high voltage power
supply units, designed specifically for photomultiplier tube op-
erations. The C4710 series is designed for ease of use and high
performance, and can be selected from among 6 models to meet
your various needs.
Compact High Voltage Power Supply Units C1309 Series
FEATURES
q
Compact and lightweight
Allows direct mounting on a PC board.
q
High stability
Ensures excellent input regulation, load regulation and drift.
q
Fully enclosed metal-shielded package
Provides effective noise shielding
FEATURES
q
q
q
q
q
Compact and lightweight
High stability
High output voltage up to 1500 V
Ample protective functions
Fully enclosed metal-shielded package
s
Specifications
Parameter
Input Voltage
Input Current
A
with no load
with full load
Specification Guaranteed Output Voltage Range
Output Current
Line Regulation against
±
1 V Input Change
B
Load Regulation against 0 % to 100 % Load Change
A
Ripple/Noise (p-p)
B
Output Voltage Control
Controlling Voltage Input Impedance
Output Voltage Setting (Absolute Value)
Output Voltage Rise Time (0 %→99 %)
B
Temperature Coefficient
B
Operating Temperature
B
Storage Temperature
Weight
Protective Functions
NOTE
s
Specifications
Parameter
C4710
C4710-01
C4710-02
C4710-50
C4710-51
C4710-52
Unit
V dc
mA Typ.
V dc
mA Max.
Input Voltage
A
Input Current
AB
Output Voltage
Specification Guaranteed Output Voltage Range
Output Current
Line Regulation
BC
Load Regulation against 0 to 100% Load Change
D
Ripple/Noise (p-p)
B
Drift (After Warm-up)
B
Programming Resistance
Programming Voltage
Output Voltage Rise Time (10 %→90 %)
B
Temperature Coefficient
BE
Warm-up Time
Operating Temperature
B
Storage Temperature
Weight
NOTE
A
With single supply voltage.
B
Maximum output voltage and current.
C
±
2 V input change for C1309-01.
±
1 V input change for C1309-02, -04 and -06.
D
Maximum output voltage.
E
Operating temperature:
+
5
°C
to
+
40
°C
C1309-01
C1309-02
C1309-04
C1309-06
Unit
V dc
mA Max.
V dc
V dc
mA Max.
% Typ.
% Typ.
mV Typ.
%/h Typ.
kΩ
V dc
ms Typ.
%/
°C
Typ.
min Typ.
°C
°C
+
12 to
+
16
300
+
14 to
+
16
170
+
14 to
+
16
170
+
14 to
+
16
250
+
15
±
1
95
260
+
12
±
1
120
340
+
24
±
1
65
145
+
15
±
1
95
260
+
12
±
1
120
340
+
24
±
1
65
145
-
400 to
-
800
-
500 to
-
800
2
-
200 to
-
1100
-
400 to
-
1100
0.7
-
200 to
-
1100
-
400 to
-
1100
0.7
-
400 to
-
1500
-
500 to
-
1500
1
-
240 to
-
1500
1
+
240 to
+
1500
±
0.015
±
0.01
0.005
±
0.01
±
0.01
±
0.015
±
0.015
±
0.02
±
0.01
±
0.02
±
0.01
±
0.015
±
0.01
% Typ.
% Typ.
% Typ.
kΩ Typ.
V Typ.
ms Typ.
% /
°C
Typ.
°C
°C
±
0.1
±
0.1
300
±
0.06
±
0.15
100
±
0.06
±
0.15
100
±
0.05
±
0.2
150
±
0.2
1
±
0.1
10
0 to
+
1.4
200
±
0.02
10
0 to
+
1.4
200
±
0.1
10
0 to
+
1.4
200
By external controlling voltage (
+
0.8 V to
+
5 V) or external potentiometer (10kΩ)
40
(Controlling Voltage
×
300)
±
0.5%
100
56
+
4.8 to
+
7
30
±
0.01
0 to
+
40
-
20 to
+
60
105
Units protected against reversed power input, reversed/ excessive controlling voltage input,
continuous overloading/short circuit in output.
±
0.05
15
±
0.03
15
±
0.005
15
±
0.02
15
+
5 to
+
40
-
5 to
+
60
140
+
5 to
+
40
-
5 to
+
60
120
+
5 to
+
40
-
5 to
+
60
120
+
5 to
+
40
–
5 to
+
60
120
g
g
A
At maximum output voltage.
B
At maximum output voltage and current.
Dimensional Outlines (Unit: mm)
65
55
27.5
8
45
Output Voltage Controlling Characteristic
Dimensional Outlines (Unit: mm)
(C4710,
−01, −02)
−1800
−1500
TACCB0009EA
(C4710−50,
−51, −52)
+1800
+1500
77
71
21
7.4
60
q
INPUT VOLTAGE
w
INPUT VOLTAGE
e
GND
r
HV ADJ
t
HV OUTPUT
y
GND
OUTPUT VOLTAGE (V)
−1200
−900
+1200
+900
1
10
1
2
+12/15/24 V dc IN
COMMON
OUTPUT VOLTAGE (V)
1.0
±
0.1
45
25
10
5
35
2
5
10
3
4
HV ADJ
HV OUT
5
10
−300
+300
2-MOUNTING THREADS (M2.3)
(SIDE VIEW)
(BOTTOM VIEW)
TACCA0124EA
0
0 0.43
1
2
3
4
5 5.3
6
0
4-No.2-56UNC
(4PCS OF SCREWS SUPPLIED)
(SIDE VIEW)
(BOTTOM VIEW)
TACCA0123EA
CONTROLLING VOLTAGE
26
4
6
V
REF
OUT
−600
+600
3
20
48
54
1
27