RoHS
Compliant
Broadband CATV, Coupler
5-1000MHz
Features
•
•
•
•
•
•
•
Surface Mount
Typical Coupling 20dB
RoHS* Compliant
RoHS version of ELDC-20.
260°C Reflow Compatible
Available on Tape and Reel.
All wires are soldered to the substrate using HMP sol-
der
MACP-008125-CK07F0
V1
Schematic
Description
M/A-COM’s MACP-008125-CK07F0 is a high
performance 75 Ohm Coupler, in a SM-55 low cost,
surface mount package. The MACP-008125-CK07F0 is
designed for use in high volume CATV applications.
Typical applications include Set-top Boxes, Network
Interface Units, Broadband Amplifiers and Headend
equipment.
Case Style: SM-127
Pin Configuration
Pin No.
1
2
3
4
5
6
Function
Output
Ground, not connected
Isolated (external 75 Ohms termination)
Coupled
Ground
Input
Part Number
MACP-008125-CK07F0
MACP-008125-CK07TB
Dimensions in inches [mm] Tolerance: .xx ± .02, .xxx ± .010
Ordering Information
Package
900 piece reel
Customer Test Board
Note: Reference Application Note
M513
for reel size information.
1
ADVANCED:
Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY:
Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
•
North America
Tel: 800.366.2266 •
Europe
Tel: +353.21.244.6400
•
India
Tel: +91.80.4155721
•
China
Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
RoHS
Compliant
Broadband CATV, Coupler
5-1000MHz
Electrical Specifications: T
A
= 25°C, Z
0
= 75Ω
1
Parameter
Mainline Loss
MACP-008125-CK07F0
V1
Test Conditions
5 - 50 MHz
50 - 870 MHz
870 - 1000 MHz
5 - 870 MHz
870 - 1000 MHz
5 - 1000 MHz
5 - 870 MHz
870 - 1000 MHz
5 - 50 MHz
50 - 1000 MHz
5 - 50 MHz
50 - 1000 MHz
5 - 50 MHz
50 - 1000 MHz
Units
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Min
—
—
—
—
—
—
10
7
20
22
20
22
20
20
Typ
0.6
0.45
0.6
20
20
—
14
9
22
27
22
28
22
27
Max
0.7
0.65
0.7
± 0.8
± 1.0
± 0.5
—
—
—
—
—
—
—
—
Coupling
Coupling Flatness
Directivity
Input Return Loss
Output Return Loss
Coupled Return Loss
Absolute Maximum Ratings
1,2
Parameter
Max Input Power
DC current
Operating Temperature
Storage Temperature
Recommended PCB Configuration
Absolute Maximum
250mW
30mA
-40°C to +85°C
-55°C to +100°C
1. Exceeding any one or combination of these limits may cause
permanent damage to this device.
2. M/A-COM does not recommend sustained operation near
these survivability limits.
2
ADVANCED:
Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY:
Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
•
North America
Tel: 800.366.2266 •
Europe
Tel: +353.21.244.6400
•
India
Tel: +91.80.4155721
•
China
Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
RoHS
Compliant
Broadband CATV, Coupler
5-1000MHz
Typical Performance Curves T
A
= 25°C, Z
0
= 75Ω
Main Line Loss
0.0
-0.2
-10
MACP-008125-CK07F0
V1
Return Loss: Input
0
-5
-0.4
dB
dB
-0.6
-0.8
-1.0
5
204
403
602
801
1000
-15
-20
-25
-30
-35
5
204
403
602
801
1000
Frequency (MHz)
Coupling
18
Frequency (MHz)
Return Loss: Output
0
-5
-19
-10
dB
dB
-20
-15
-20
-21
-25
-30
-22
5
204
403
602
801
1000
-35
5
204
403
602
801
1000
Frequency (MHz)
Frequency (MHz)
Directivity
0
-5
Return Loss: Coupled
0
-5
-10
-15
-20
-25
-30
-35
5
204
403
602
801
100
-10
-15
-20
-25
-30
-35
5
204
403
602
801
1000
dB
dB
Frequency (MHz)
•
North America
Tel: 800.366.2266 •
Europe
Tel: +353.21.244.6400
•
India
Tel: +91.80.4155721
•
China
Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
3
Frequency (MHz)
ADVANCED:
Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY:
Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.