Notice for TAIYO YUDEN products
Please read this notice before using the TAIYO YUDEN products.
REMINDERS
■
Product information in this catalog is as of October 2011. All of the contents specified herein are subject to change
without notice due to technical improvements, etc. Therefore, please check for the latest information carefully be-
fore practical application or usage of the Products.
Please note that Taiyo Yuden Co., Ltd. shall not be responsible for any defects in products or equipment incorpo-
rating such products, which are caused under the conditions other than those specified in this catalog or individual
specification.
■
Please contact Taiyo Yuden Co., Ltd. for further details of product specifications as the individual specification is
available.
■
Please conduct validation and verification of products in actual condition of mounting and operating environment
before commercial shipment of the equipment.
■
All electronic components or functional modules listed in this catalog are developed, designed and intended for
use in general electronics equipment.(for AV, office automation, household, office supply, information service,
telecommunications, (such as mobile phone or PC) etc.). Before incorporating the components or devices into any
equipment in the field such as transportation,( automotive control, train control, ship control), transportation signal,
disaster prevention, medical, public information network (telephone exchange, base station) etc. which may have
direct influence to harm or injure a human body, please contact Taiyo Yuden Co., Ltd. for more detail in advance.
Do not incorporate the products into any equipment in fields such as aerospace, aviation, nuclear control, subma-
rine system, military, etc. where higher safety and reliability are especially required.
In addition, even electronic components or functional modules that are used for the general electronic equipment,
if the equipment or the electric circuit require high safety or reliability function or performances, a sufficient reliabil-
ity evaluation check for safety shall be performed before commercial shipment and moreover, due consideration to
install a protective circuit is strongly recommended at customer's design stage.
■
The contents of this catalog are applicable to the products which are purchased from our sales offices or distribu-
“TAIYO
YUDEN’ official sales channel”
tors (so called
s
).
It is only applicable to the products purchased from any of TAIYO YUDEN’ official sales channel.
s
■
Please note that Taiyo Yuden Co., Ltd. shall have no responsibility for any controversies or disputes that may oc-
cur in connection with a third party's intellectual property rights and other related rights arising from your usage of
products in this catalog. Taiyo Yuden Co., Ltd. grants no license for such rights.
■
Caution for export
Certain items in this catalog may require specific procedures for export according to
“Foreign
Exchange and For-
eign Trade Control Law”of Japan,
“U.S.
Export Administration Regulations” and other applicable regulations.
,
Should you have any question or inquiry on this matter, please contact our sales staff.
1
2
notice_e-01
RADIAL LEADED INDUCTORS
WAVE
■
FEATURES
◦
The LHL08~LHL16 series radial inductors are encapsulated in a resin
housing which adds to the stability of the mounted part on a printed
circuit board.
◦
The LHL08/LHL10/LHL13/LHL16 series are for high current applica-
tions.
◦
The LHLP10/LHLP12/LHLP16 series are shielded type for high current ap-
plications.
◦
LHLP10 series is also available in packaging.
◦
LHLC08/LHLC10 series which are encapsulated in a resin housing, are ra-
dial leaded inductor for high current applications.
■
APPLICATIONS
◦
Ideal for use as a power choke coil in general household appliances
(TVS, PDPTV, LCDTV, DVD, etc) and industrial equipment.
◦
Can also be used as a peaking coil in filtering applications.
◦
For DC/DC converter (LCD TV, PDP TV, CTV, DVD etc.) (LHLC Series)
■
OPERATING TEMP.
◦ー25℃½105℃
(Including
self-generated heat)
■
ORDERING CODE
L
H
△
❶
L
❷
△
0
❸
8
T
❹
B
NB
TB
1
0
❺
1
K
○ ○ ○
❻
❼
❻Inductance
Tolerances (%)
J
±5
K
±10
M
±20
N
±30
❼Internal
code
△△△
Standard product
△=Blank
space
❶Type
LH Radial leaded inductor
❷Configuration
L△ Standard type Taping available
LP Shielded type Bulk
LC
High current type
△=Blank
space
❸External
dimensions
〔mm
max〕
08
9.0
10
11.0
12
13.0
13
14.0
16
17.0
❹Packaging
Code
Bulk (LHL)
Ammo packaging (LHL)
❺Nominal
Inductance
(μH)
example
1R0
150
102
1.0
15
1000
※R=Decimal
point
■
EXTERNAL DIMENSIONS/STANDARD QUANTITY
Type
LHL08
LHL10
LHL13
LHL16
LHLP10
LHLP12
LHLP16
Fig.
D
9.0 max.
(0.354
max.)
11.0 max.
(0.433
max.)
14.0 max.
(0.551
max.)
17.0 max.
(0.669
max.)
11.0 max.
(0.433
max.)
13.0 max.
(0.512
max.)
17.0 max.
(0.669
max.)
H
2
9.5 max.
(0.374
max.)
14.0 max.
(0.551
max.)
17.0 max.
(0.669
max.)
21.0 max.
(0.827
max.)
11.0 max.
(0.433
max.)
16.0 max.
(0.624
max.)
19.0 max.
(0.741
max.)
ℓ
5.0±1.0
(0.197±0.039)
5.0±1.0
(0.197±0.039)
5.0±1.0
(0.197±0.039)
5.0±1.0
(0.197±0.039)
5.0±1.0
(0.197±0.039)
5.0±1.0
(0.197±0.039)
5.0±1.0
(0.197±0.039)
F
5.0±1.0
(0.197±0.039)
5.0±1.0
(0.197±0.039)
7.5±1.0
(0.295±0.039)
7.5±1.0
(0.295±0.039)
5.0±1.0
(0.197±0.039)
5.0±1.0
(0.197±0.039)
7.5±1.0
(0.295±0.039)
φd
0.6±0.05
(0.024±0.002)
0.6±0.05
(0.024±0.002)
0.8±0.05
(0.031±0.002)
0.8±0.05
(0.031±0.002)
0.6±0.05
(0.024±0.004)
0.6±0.05
(0.024±0.004)
0.8±0.05
(0.031±0.004)
Standard Quantity (pcs)
Taped
Box
Bulk
ー
ー
ー
500
500
300
200
100
50
25
ー
ー
ー
ー
1000
500
500
250
200
ー
ー
Unit:mm
(inch)
【LH
type】
Type
LHLC08
LHLC10
Fig.
D
9.0max
(0.354max)
11.0max
(0.433max)
H
2
ℓ
F
5.0±1.0
(0.197±0.039)
5.0±1.0
(0.197±0.039)
φd
0.6±0.05
(0.024±0.002)
0.6±0.05
(0.024±0.002)
Standard Quantity (pcs)
Taped
Bulk
100
50
1000
500
Unit:mm
(inch)
9.5max
5.0±1.0
(0.374max) (0.197±0.039)
14.0max
5.0±1.0
(0.551max) (0.197±0.039)
*
This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
112
1
2
leaded_i02_e-01
■
PART NUMBERS
●LHL13
Ordering code
LHL13□100K
LHL13□150K
LHL13□220K
LHL13□330K
LHL13□470K
LHL13□680K
LHL13□101K
LHL13□151K
LHL13□221K
LHL13□331K
LHL13□471K
LHL13□681K
LHL13□102J
LHL13□152J
LHL13□222J
LHL13□332J
LHL13□472J
LHL13□682J
LHL13□103J
EHS (Environmental
Hazardous
Substances)
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
[μH]
10
15
22
33
47
68
100
150
220
330
470
680
1000
1500
2200
3300
4700
6800
10000
Inductance
Tolerance
Q
(min.)
140
100
70
±10%
50
40
Self-resonant
frequency
〔MHz〕
(min.)
19
12
7.6
6.9
5.6
4.4
3.3
2.6
2.2
1.8
1.5
1.2
1.0
0.83
0.70
0.60
0.43
0.38
0.30
DC Resistance
[Ω] (max.)
0.023
0.028
0.035
0.043
0.052
0.070
0.12
0.19
0.23
0.35
0.43
0.61
1.2
1.8
2.2
3.4
4.7
5.6
10
Rated current
〔A〕
(max.)
4.5
4.0
3.4
3.2
2.8
2.4
2.0
1.5
1.3
1.1
0.90
0.80
0.60
0.45
0.40
0.33
0.28
0.25
0.19
Measuring
frequency
〔MHz〕
2.52
0.796
30
INDUCTORS LEADED INDUCTORS
40
±5%
30
70
0.252
L:1kHz
Q:0.0796MHz
□
Please specify the packaging code. (TB: Taping, NB: Bulk)
/
●LHL16
Ordering code
LHL16□470K
LHL16□680K
LHL16□101K
LHL16□151K
LHL16□221K
LHL16□331K
LHL16□471K
LHL16□681K
LHL16□102J
LHL16□152J
LHL16□222J
LHL16□332J
LHL16□472J
LHL16□682J
LHL16□103J
EHS (Environmental
Hazardous
Substances)
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
[μH]
47
68
100
150
220
330
470
680
1000
1500
2200
3300
4700
6800
10000
Inductance
Tolerance
Q
(min.)
70
Self-resonant
frequency
〔MHz〕
(min.)
4.5
3.9
2.7
2.3
1.9
1.6
1.4
1.2
0.84
0.69
0.56
0.49
0.41
0.35
0.26
DC Resistance
[Ω] (max.)
0.046
0.054
0.077
0.11
0.15
0.21
0.28
0.35
0.74
0.93
1.4
2.2
2.6
3.9
7.3
Rated current
〔A〕
(max.)
3.7
3.3
2.9
2.4
2.0
1.5
1.3
1.1
0.86
0.75
0.60
0.50
0.40
0.33
0.25
Measuring
frequency
〔MHz〕
2.52
±10%
60
40
30
0.796
20
±5%
0.252
70
L:1KHz
Q:0.0796MHz
□
Please specify the packaging code. (TB: Taping, NB: Bulk)
●LHLP10
Ordering code
LHLP10□100M
LHLP10□150M
LHLP10□220M
LHLP10□330M
LHLP10□470M
LHLP10□680M
LHLP10□101K
LHLP10□151K
LHLP10□221K
LHLP10□331K
LHLP10□471K
LHLP10□681K
LHLP10□102K
EHS (Environmental
Nominal Inductance
Hazardous
[μH]
Substances)
RoHS
10
RoHS
15
RoHS
22
RoHS
33
RoHS
47
RoHS
68
RoHS
100
RoHS
150
RoHS
220
RoHS
330
RoHS
470
RoHS
680
RoHS
1000
L Measuring
frequency
Inductance
Tolerance
DC Resistance
[Ω] (max.)
0.038
0.049
0.075
0.094
0.15
0.23
0.30
0.47
0.70
0.88
1.3
1.9
3.2
Rated current
〔A〕
(max.)
2.5
2.2
1.9
1.7
1.3
1.0
0.90
0.78
0.63
0.58
0.46
0.38
0.30
2.52
±20%
0.796
±10%
0.252
□
Please specify the packaging code. (TB: Taping, NB: Bulk)
●LHLP12NB
Ordering code
LHLP12NB150M
LHLP12NB220M
LHLP12NB330M
LHLP12NB470M
LHLP12NB680M
LHLP12NB101K
LHLP12NB151K
LHLP12NB221K
LHLP12NB331K
LHLP12NB471K
LHLP12NB681K
LHLP12NB102K
EHS (Environmental
Nominal Inductance
Hazardous
[μH]
Substances)
RoHS
15
RoHS
22
RoHS
33
RoHS
47
RoHS
68
RoHS
100
RoHS
150
RoHS
220
RoHS
330
RoHS
470
RoHS
680
RoHS
1000
L Measuring
frequency
Inductance
Tolerance
DC Resistance
[Ω] (max.)
0.035
0.050
0.070
0.081
0.12
0.16
0.24
0.38
0.46
0.69
1.1
1.8
Rated current
〔A〕
(max.)
3.3
2.7
2.4
2.1
1.7
1.6
1.3
0.95
0.89
0.74
0.58
0.46
2.52
±20%
0.796
±10%
0.252
*
This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
leaded_i02_e-01