over-voltage protection, short circuit protection,
output over-current protection
Operating temperature range: -40℃ to +85℃
Meet CISPR22/EN55022 CLASS A
A2S (wring mounting) and A4S (TS35 rail mounting)
products featuring anti-reverse connection for
input
Meet UL60950/ EN60950/ IEC60950 Certified
International standard pin-out
CB
Patent Protection
RoHS
URE_LP-10WR3 & URF_LP-10WR3 series are isolated 10W DC-DC products with 4:1 input voltage. They feature efficiency up to 87%, 3000VDC
isolation, operating temperature of -40℃~+85℃, Input under-voltage protection, output short circuit protection, over-voltage protection,
over-current protection and EMI meets CISPR22/EN55022 CLASS A, which make them widely applied in industrial control, electric power,
instruments and communication fields. And extension package A2S and A4S also enable them with reverse voltage protection.
Selection Guide
Certification
Part No.
①
URE2405LP-10WR3
--
URE2412LP-10WR3
URE2415LP-10WR3
URF2403LP-10WR3
URF2405LP-10WR3
UL/CE/CB
URF2409LP-10WR3
URF2412LP-10WR3
URF2415LP-10WR3
URF2424LP-10WR3
URE4805LP-10WR3
--
URE4812LP-10WR3
URE4815LP-10WR3
URF4803LP-10WR3
URF4805LP-10WR3
UL/CE/CB
URF4812LP-10WR3
URF4815LP-10WR3
URF4824LP-10WR3
48
(18-75)
80
24
(9-36)
40
Input Voltage (VDC)
Nominal
(Range)
Max.
②
Output
Output
Voltage (VDC)
±5
±12
±15
3.3
5
9
12
15
24
±5
±12
±15
3.3
5
12
15
24
Output Current (mA)
(Max./Min.)
±1000/0
±416/0
±333/0
2400/0
2000/0
1111/0
833/0
667/0
416/0
±1000/0
±416/0
±333/0
2400/0
2000/0
833/0
667/0
416/0
Efficiency
③
(%,Typ.)
@ Full Load
80/82
84/86
85/87
77/79
80/82
83/85
84/86
85/87
85/87
80/82
84/86
85/87
77/79
80/82
84/86
85/87
85/87
Max.
Capacitive
Load(µF)
1000
330
220
5400
5400
680
470
330
100
1000
330
220
5400
5400
470
330
100
Notes:
①Part
No. with suffix of “A2S” means chassis mounting and suffix of “A4S” means DIN-Rail mounting (e.g. URF2405LP-10WR3A2S means chassis mounting;
URF2405LP-10WR3A4S means DIN-Rail mounting);
②Absolute
maximum rating without damage on the converter, but it isn't recommended;
③Efficiency
is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection, minimum
efficiency greater than Min.-2 is qualified;
④The
capacitive loads of positive and negative outputs are identical.
2015.11.16-A/3
Page 1 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URE_LP-10WR3 & URF_LP-10WR3 Series
Input Specifications
Item
Input Current (full load / no-load)
Reflected Ripple Current
Input impulse Voltage (1sec. max.)
Starting Voltage
Operating Conditions
24V Input
48V Input
24V Input
48V Input
24V Input
48V Input
24V Input
48V Input
24V Input
48V Input
Nominal input& constant resistance load
Min.
--
--
--
--
-0.7
-0.7
--
--
5.5
14
--
Typ.
508/5
254/4
40
30
--
--
--
--
6.5
15.5
10
Pi filter
Max.
521/12
261/12
--
--
50
100
9
18
--
--
--
Unit
mA
VDC
I
nput under-voltage protection
Starting Time
Input Filter
Hot Plug
ms
Unavailable
Module switch on
Ctrl suspended or connected to TTL high level
(3.5-12VDC)
Ctrl pin connected to GND or low level (0-1.2VDC)
--
5
8
mA
Ctrl*
Module switch off
Input current when switched off
Note: * the voltage of Ctrl pin is relative to input pin GND.
Output Specifications
Item
Output Voltage Accuracy
①
Operating Conditions
0%-100% load
Dual output, balanced load
Full load, the input voltage is from
low voltage to high voltage
②
Min.
--
--
Positive output
Negative
Positive output
Negative
--
--
--
--
--
--
--
--
--
110
110
Typ.
±1
±1
±0.2
±0.5
±0.5
±0.5
--
300
±3
--
60
130
140
Max.
±3
±2
±0.5
±1.0
±1
±1.5
±5
500
±5
±0.03
120
160
190
Unit
Balance of Output Voltage
Line Regulation
%
Load Regulation
5%-100% load
Cross Regulation
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Ripple & Noise
③
Over-voltage Protection
Over-current Protection
Short circuit Protection
Dual output, main circuit with 50% load,
auxiliary circuit with 10%-100% load
25% load step change
Full load
20MHz bandwidth, 5%-100% load
Input voltage range
µs
%
%/℃
mV p-p
%Vo
%Io
Continuous
Note:
①At
0%~5% load, the Max. output voltage accuracy of ±5VDCoutput converter is ±5%;
②When
testing from 0% to100%load working conditions,load regulation index of ±5%;
③0%-5%
load ripple&Noise is no more than 5%Vo.Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application
Notes for specific operation.
General Specifications
Item
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Operating Temperature
Storage Temperature
Operating Conditions
Input-output, with the test time of 1 minute and the
leak current lower than 1mA
Input-output, insulation voltage 500VDC
Input-output, 100KHz/0.1V
Derating if the temperature is
≥71℃(see
Fig. 1)
Min.
3000
1000
--
-40
-55
Typ.
--
--
500
--
--
Max.
--
--
--
+85
+125
Unit
VDC
MΩ
pF
℃
2015.11.16-A/3
Page 2 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URE_LP-10WR3 & URF_LP-10WR3 Series
Storage Humidity
Pin Welding Resistance
Temperature
Vibration
Switching Frequency*
MTBF
PWM mode
MIL-HDBK-217F@25℃
--
1000
Non-condensing
Welding spot is 1.5mm away from the casing, 10
seconds
5
--
--
--
95
+300
%RH
℃
10-55Hz, 10G, 30 Min. along X, Y and Z
350
--
--
--
KHz
K hours
Note:* This series of products using the technique of reducing frequency. The switching frequency is test at full load; when the load is below 50%, the switching