All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of
the relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and
to request our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without
notification. All rights of Tyco are reserved.
100
Please observe the disclaimer.
PCB relays
Single relays
Mini power relay K (open)
Dimensional drawing
Open version
.512±.008
(13.0
±0.2)
.591
±.039
(15
±1)
Ø .138
(3.5)
Catalog 1308028
Issued 01-05
.374
±.008
(9.5
±0.2)
.571
±.016
(14.5
±0.4)
.689
±.020
(17.5
±0.5)
.008 … .055
(0.2 … 1.4)
.138
±.012
*)
(3.5
±0.3)
*) additional tin tops
max .039 inch (1 mm)
.157
±.039
(4
±1)
Terminals tinned
.035
±.006
(0.9
±0.15)
.240
±.012
(6.1
±
0.3)
.264
±.012
(6.7
±
0.3)
Tyco0595-Z
View of the terminals
(Bottom view)
Ø .033
±.002
(0.85
±0.05)
.033
±.002
(0.85
±0.06)
4 x .033
±.002
(0.85
±0.06)
.030
±.002
(0.75
±0.06)
.022
±.002
(0.55
±0.05)
ECR2209-U
Mounting holes
View of the terminals
(Bottom view)
Grid 0.049 … 0.050" (1.25 … 1.27 mm)
Ø .512 +.004
(1.3 +0.1)
.049 … .050
(1.25 … 1.27)
.039
±.018
(1
±0.45)
.091 max.
(2.3 max.)
.047
±.016
(1.2
±0.4)
.056
±.010
(1.42
±0.25)
Tyco0596-8
101
Please observe the disclaimer.
PCB relays
Single relays
Mini power relay K (sealed)
Dimensional drawing
Sealed version
.579
±.012
(14.7
±0.3)
.665
±.012
(16.9
±0.3)
The Nipp-off-pin may be
removed after soldering
and washing
(for ventilation)
Catalog 1308028
Issued 01-05
Assembly and
Nipp-off-pin
positioning aid
.756
±.012
(19.2
±0.3)
.018
±.016
(0.45
±0.4)
.118
±.012
*)
(3
±0.3)
*) additional tin tops
max .039 inch (1 mm)
.012
±.008
(0.3
±0.2)
Tyco1112-3
Terminals tinned
View of the terminals
(Bottom view)
.075
±.008
(1.9
±0.2)
2 x Ø .033
±.002
(0.85
±0.05)
.181
±.008
(4.6
±0.2)
Ø .079
±.004
(Ø 2
±0.1)
.354
±.008
(9
±0.2)
.033
±.002
(0.85
±0.06)
.033
±.002
(0.85
±0.06)
.030
±.002
(0.75
±0.06)
4 x .022
±.002
(0.55
±0.05)
ECR2210-X
Mounting holes
View of the terminals
(Bottom view)
Grid 1.25 … 1.27 mm
Ø .512 +.004
(1.3 +0.1)
.049 … .050
(1.25 … 1.27)
.094
±.024
(2.4
±0.6)
ECR0598-P
.106
±.016
(2.7
±0.4)
102
Please observe the disclaimer.
PCB relays
Single relays
Mini power relay K (open and sealed)
Catalog 1308028
Issued 01-05
Contact data
Typical areas of application
Contact configuration
Make
contact/
Form A
Resistive / inductive loads
Changeover
Double
contact/
make contact/
Form C
Form U
3
5
Indicator lamps
Make
Double
contact/
make contact/
Form A
Form U
Circuit symbol
(see also Pin assignment)
4
Rated voltage
Rated current at 85 °C
Contact material
Max. switching voltage/power
Max. switching current
1)
On
2)
Off
Min. recommended load
5)
Voltage drop at 10 A (initial)
for NC/NO contacts
Mechanical endurance (without load)
Electrical endurance
(example of resistive load)
1)
2)
10 A
5 A/10 A
AgNi0.15
12 V
2x6A
See load limit curve
5A
AgSnO
2
2x5A
60 A
20 A
NC/NO
12 A/60 A
10 A/20 A
2 x 40 A
2 x 20 A
1 A at 5 V
60 A
3)
6A
120 A
3)
12 A
Typ. 50 mV, 300 mV max.
Typ. 2 x 50 mV, 300 mV max.
> 10
7
operations
5
operations
> 2 x 10
10 A, 13.5 V
Typ. 150 mV, 300 mV max.
> 1,5 x 10
6
operations
up to 3 x 21 W
> 1.5 x 10
6
operations
up to 6 x 21 W
The values apply to a resistive load or inductive load with suitable spark suppression.
For a load current duration of maximum 3 s for a make/break ratio of 1:10.
3)
Corresponds to the peak inrush current on initial actuation (cold filament).
4)
At 50 % ON period
5)
See chapter Diagnostics in our Application Recommendations on page 18.
Load limit curve
Tyco0626-Y
Tyco
Load limit curve 1
^
safe shutdown,
=
connected as form X, load on pin 5
and 7
Load limit curve 2
^
safe shutdown,
=
no stationary arc / make contact
Load limit curve 3
^
arc extinguishes
=
during transit time (changeover contact)
Load limit
Load limi
curve
curve 1
1
Load limit
Load limi
curve 2
2
curve
Load limit
Load
curve 3
limi
curve 3
Pin assignment (open and sealed)
1 make contact/
1 form A
1 double make contact/
1 form U
1 changeover contact/
1 form C
103
Please observe the disclaimer.
PCB relays
Single relays
Mini power relay K (open and sealed)
Catalog 1308028
Issued 01-05
Coil data
Available for nominal voltages
Nominal power consumption of the unsuppressed coil at nominal voltage
Test voltage winding/contact
Maximum ambient temperature range
1)
Operate time at nominal voltage
2)
Release time at nominal voltage
1)
2)
12, 24 V
(other coils on request)
1.1 W
500 VAC
rms
– 40 to + 85 °C
Typ. 3 ms
Typ. 1.5 ms
See also operating voltage range diagram
Measured at nominal voltage without coil suppression unit
N.B.
A low resistive suppression device in parallel to the relay coil increases the release time and reduces
the lifetime caused by increased erosion and/or higher risk of contact tack welding.
Operating voltage range
Does not take into account
the temperature rise due to
the contact current
E = pre-energization
Mechanical data
Enclosure
Sealed
Sealed relay is suitable for immersion cleaning of PCB assembly or conformal coating.
Please refer to the Application Recommendations in this catalog.