LCA
FEATURES
+ 85°C Low Leakage
Current Aluminum
Electrolytic Capacitors
85
220
6v
I
Wide Capacitance Range (.1 to 100 µF)
I
Standard Case Sizes
I
Operating Voltage Range: 6.3 WVDC to 50 WVDC
SPECIFICATIONS
Capacitance Tolerance
Operating Temperature Range
Dissipation Factor
120Hz, 20°C (Max) tan
δ
Leakage current
Impedance Ratio at Low
Temperature (120Hz)
WVDC
tanδ
Time
-25°C/20°C
-40°C/20°C
4
8
3
6
2
4
6.3
.24
10
.20
16
.16
25
.14
35
.12
±20% at 120Hz, 20°C
-40°C to +85°C
50
.1
2 minutes
.002 CV or .5µA, whichever is greater
2
4
2
3
2
3
2,000 hours at 85°C with rated voltage
Load Life
Capacitance change
Dissipation factor
Leakage current
≤
25% of initial measured values
≤
200% initial specified value
≤100%
Initial specified value
1000 hours at 85°C with no applied voltage.
Shelf Life
Resistance to
Soldering Heat
Ripple Current
Multipliers
Capacitance change
Dissipation factor
Leakage current
≤
20% of initial measured values
≤
Initial specified value
≤
Initial specified value
Capacitors placed on a 250°C hot plate for 30 seconds with their electrode terminals facing
downward will fulfill the following conditions after being cooled to room temperature.
Frequency (Hz)
50
.8
120
1.0
400
1.0
1K
1.1
10K
1.3
100K
1.5
Temperature (°C)
85°C
1.0
70°C
1.35
65°C
1.35
®
3757 W. Touhy Ave., Lincolnwood, IL 60712 • (847) 675-1760 • Fax (847) 673-2850 • www.illcap.com