20 A (resistive) Max. Continuous Load (Output) Current with Heat Sink
264V AC Max. Load Voltage Range
5,12, or 24V DC Control/Input Voltage
Built-in Varistor Helps Absorb Most Electrical Surges
Low Profile (Flat Pack) Design
Quick-Connect #110 Input and #250 Output Terminals
Table Of Contents
Product Selection . . . . . . . . 42
Accessories . . . . . . . . . . . . . 43
Specifications . . . . . . . . . . . 44
Approximate
Dimensions . . . . . . . . . . . . . 46
Input-to-
Output
Isolation
Method
Zero Cross
Function
LED
Indicator
Rated Output (Load)
Max. Current and
Voltage Range
➊
Rated Input
Control Voltage
Cat. No.
Factory-
stocked
Item
(single
pack)
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
5V DC
5 A at 100…240V AC
12V DC
24V DC
5V DC
Yes
10 A at 100…240V AC
12V DC
24V DC
5V DC
20 A at 100…240V AC
Phototriac
No
5V DC
5 A at 100…240V AC
12V DC
24V DC
5V DC
No
10 A at 100…240V AC
12V DC
24V DC
5V DC
20 A at 100…240V AC
12V DC
24V DC
12V DC
24V DC
700-SE05GZZ05
700-SE05GZZ12
700-SE05GZZ24
700-SE10GZZ05
700-SE10GZZ12
700-SE10GZZ24
700-SE20GZZ05
700-SE20GZZ12
700-SE20GZZ24
700-SE05GNZ05
700-SE05GNZ12
700-SE05GNZ24
700-SE10GNZ05
700-SE10GNZ12
700-SE10GNZ24
700-SE20GNZ05
700-SE20GNZ12
700-SE20GNZ24
➊
Maximum load current when mounted on a heat sink.
42
Bulletin 700-SE
Solid-State Relays
Accessories
Description
Pkg. Quantity
Cat. No.
Factory-stocked Item
Heat Sink — Panel or DIN Rail Mount
➊
1
700-S10
✔
Cat No. 700-S10
Heat Sink — Panel or DIN Rail Mount
➊
1
700-S20
✔
Cat No. 700-S20
DIN Rail Mounting Pack
Standard 35 x 7.5 mm DIN Rail, 1 meter long,
10 rails per package. Order must be for 10
rails or multiples of 10.
Cat No. 199-DR1
10
199-DR1
✔
➊
Refer to "Load Current Vs. Ambient Temperature Characteristics" page 45 for information about how to select the correct size of heat sink for your application
( cat. no. 700-S10, 700-S20).
43
Bulletin 700-SE
Solid-State Relays
Specifications
Control/Input Ratings
➊
Rated
Control
Voltage
5V DC
12V DC
24V DC
Input Impedance
Operating Control
Voltage Range
4…6V DC
9.6…14.4V DC
19.2…28.8V DC
With Zero
Cross Function
250
Ω ±
20%
600
Ω ±
20%
1.6k
Ω ±
20%
Load/Output Ratings
Applicable Load
Cat. No.
Continuous Load Current (Resistive)
Rated Load Voltage
Load Voltage Range
With Heat Sink
➋
Min.
700-SE05…
700-SE10…
700-SE20…
Characteristics
Item
Load Switching Method/Device
Pick-up time
Drop-out time
Output ON voltage drop
Output Leakage current
Output
V
DRM
V
CEO
(V)
Output di/dt (A/uS)
Output dv/dt (V/uS)
Output
I
2
t (A
2
S)
Output Tj (°C) max.
Insulation resistance
Dielectric strength
Vibration resistance (max.)
Shock resistance (max.)
Ambient temperature
Ambient humidity
Standards
Weight
Operating
600
SE05GZ=100
SE10GZ & SE20 GZ =50
SE05GZ=200, SE10GZ=500, SE20GZ=100
SE05GZ =24.5, SE10GZ =60, SE20GZ =260
125
100 MΩ min. (at 500V DC)
2,000V AC, 50/60 Hz for 1 min.
10…55 Hz, 1.5 mm double amplitude (10 G)
1,000 m/s
2
(100 G)
Operating: –30…80°C (–22…176°F) with no icing or condensation
Storage: –30…100°C (–22…212°F) with no icing or condensation
45…85% (no condensation)
UL 508, CSA C22.2 , TUV, CE
Approx. 37 g
700-SE_ _ _Z…
Triac
1/2 of load power source cycle + 1 ms max.
1/2 of load power source cycle + 1 ms max.
1.6 V (RMS) max.
5 mA max. (at 100V AC)
10 mA max. (at 200V AC)
600
SE05GN=100
SE10 GN & SE20GN =50
SE05GN =200, SE10GN =500, SE20GN
=100
SE05GN =24.5, SE10GN =60, SE20GN =260
125
1 ms max.
700-SE_ _ _N…
100…240V AC
75…264V AC
0.1 A
0.1 A
0.1 A
Max.
5A
10 A
20 A
Without Heat Sink
➋
Min.
0.1 A
0.1 A
0.1 A
Max.
5A
5A
5A
60 A (@50/60 Hz,
1 cycle)
150 A (@50/60 Hz,
1 cycle)
220 A (@50/60 Hz,
1 cycle)
Max. Inrush Current
➌
Without Zero
Cross
Function
300
Ω ±
20%
800
Ω ±
20%
Control Voltage Levels
Pick-up Voltage
4V DC max.
9.6V DC max.
19.2V DC max.
1V DC min.
Drop-out Voltage
Cat. No.
700-SE_ _ _Z05
700-SE_ _ _Z12
700-SE_ _ _Z24
➊
Each 5 A, 10 A, and 20 A model has 5V DC, 12V DC, and 24V DC input versions.
➋
Refer to "Load Current Vs. Ambient Temperature Characteristics" graphs page 45 regarding maximum load current with and without heat sinks.
➌
If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to the “Inrush Current Resistivity” graphs on page 45 for more details.
44
Bulletin 700-SE
Solid-State Relays
Specifications, Continued
Load Current vs. Ambient Temperature Characteristics
700-SE05…
700-SE10…
With standard heat sink (700-S10)
or aluminum plate measuring
100 mm x 100 mm x 2 mm (W x H x D)
700-SE20…
With standard heat sink (700-S20) or
aluminum plate measuring 300 mm x
300 mm x 2 mm (W x H x D)
Without heat sink
Load current (A)
Load current (A)
Without heat sink
Load current (A)
Without heat sink
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
Inrush Current Resistivity
➊
700-SE05...
700-SE10...
700-SE20...
Inrush current (A. Peak)
Inrush current (A. Peak)
Energizing time (ms)
Energizing time (ms)
Inrush current (A. Peak)
Energizing time (ms)
➊
Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability
once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
45
Bulletin 700-SE
Solid-State Relays
Approximate Dimensions
Mounting Considerations
➊➋➌
Note: All units are in millimeters unless otherwise indicated. Dimensions are not intended for manufacturing purposes.
3.5 dia. hole
47.5
max.
Terminal Arrangement/
Internal Connections
(Top View)
37.5 max.
30±0.5
14.5
Input
voltage
6.5
Two #250 (t = 0.8) (Faston
tab or equivalent)
7.95
3
11.5 max.
3+
Input
4-
Input
1
Load
2
Load power
supply
Two #110 (t = 0.5) (Faston tab
or equivalent)*
7.1
2.9
6
Mounting Holes
Two, 3.5-dia. or M3 holes
30±0.2
➊
The proper mounting orientation of the heat sink is so the heat fins run perpendicular to the floor (vertical) to maximize ventilation flow. If the fins do not run perpendicular
to the floor, a 30% current derating is required.
➋
When attaching a heat sink to Bulletin 700-SE, apply heat conductive grease on the heat sink to maximize heat transfer between the SSR and the heat sink.
Recommended types: Silicon based, Toshiba YG6240; Non-silicon based, AOS company type 53300.
➌
Tighten the SSR’s panel/heat sink mounting screws to a torque of 0.78…0.98 Nm (6.9…8.7 lb.-in.)
Heat Sinks
Cat. No. 700-S10
Weight: Approx. 200 g
4.6 dia. hole
Two, M3 holes
Two, M4 holes
Two, 3.2-dia.
holes
90±0.4
35 30.5±0.3
44 max. 30
47 max.
Two, 4.4-dia.
or M4 holes
Mounting Holes
➍
47.6
77 max.
90±0.3
100 max.
5.6
5
6
51 max.
4.5
35±0.2
Cat. No. 700-S20
Weight: Approx. 400 g
4.6 dia. hole
Two, M3 holes
Two, M4
holes
Two, 3.2-dia. holes
Mounting Holes
35 30.5±0.3
71 max.
30
75 max.
90±0.4
Two, 4.4-dia.
or M4 holes
47.6
77 max.
90±0.3
100 max.
5.6
28
5
100 max.
13
4.5
35±0.2
➍
Tighten the heat sink’s panel mounting screws (M4) to a torque of 0.59…0.98 Nm (5.22…8.67 lb.-in.).
Basic Application Considerations
R
C
+
Input
–
SSR
• Because the operation time of Bulletin 700-SE is extremely short, take measures to suppress noise induced between the
input
terminals. If generation of strong
noise is expected, connect an external noise absorber such as an RC circuit.
• Do not apply excessive force to the terminals. Exercise care when pulling or inserting the terminal clips.
• Bulletin 700-SE has a built-in varistor to absorb most inrush/surge currents when operating AC inductive loads If additional suppression is required, connect an
external varistor across the load device terminals. Select a varistor that meets the load voltage outlined in the table below.
• For additional details on applying solid-state relays, refer to pub. 700-AT001A-EN-P, "Solid-State Relay Application Guide." Document available at