RP
RP110 Series
RP110
COMPACT TO 30A
CHASSIS MOUNT FILTER
ROHS COMPLIANT
RADIUS POWER
Your Power Partner
Compact Single Stage Power Line Filter
SPECIFICATIONS
Operating Freq.
Usable Freq.
Max. Operating Voltage
Ambient Temperature
Climatic Category
Hipot Rating (L-G)
Terminals (-T)
Safety Approvals
Typ. Weight, LBS (KG)
:
:
:
:
:
:
:
:
:
:
50/60Hz
DC - 400Hz
250V +10%
-25 to 40C
25/100/21
2700VDC
QD: 0.25 Tabs
S: 30A (M4)
cURus, EN60939
0.4 (0.2)
0
LEAKAGE CURRENT
Y-cap, nF
.47
1
2.2
4.7
10
mA,
120V/60Hz
0
0.04
0.09
0.2
0.4
0.9
mA,
250V/60Hz
0
0.08
0.18
0.4
0.8
1.8
PART NUMBER/ ORDERING
RP110
-X
(Amps)
3
6
10
20
30
-Y
(Ycap, nF)
0
.47
1
2.2
4.7
10
Note:
Use any combination of -Y with any -X (Amps) rating
e.g. RP110-3-2.2-QD (3 Amps with 2.2nF Ycap)
-T
SCHEMATIC
QD
S
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
10
RP
RP110
Typical Insertion Loss, dB (50/50ohm)
3 Amp
FREQ (MHz)
CM(dB)
DM(dB)
.15
48
30
.5
45
48
1.0
40
60
10
40
55
30
40
55
RADIUS POWER
Your Power Partner
Mechanical Dimensions
3/6/10/20A
6 Amp
FREQ (MHz)
CM(dB)
DM(dB)
.15
40
28
.5
40
40
1.0
40
50
10
40
70
30
40
60
10 Amp
FREQ (MHz)
CM(dB)
DM(dB)
.15
28
28
.5
40
40
1.0
44
54
10
44
70
30
34
66
30A
20 Amp
FREQ (MHz)
CM(dB)
DM(dB)
.15
15
28
.5
24
38
1.0
30
50
10
54
54
30
54
70
TYPICAL TOLERANCE: +/-0.02 (0.50)
30 Amp
FREQ (MHz)
CM(dB)
DM(dB)
.15
13
20
.5
22
32
1.0
30
50
10
52
55
30
50
60
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
11