Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
89907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet
For more Information
please call
1-800-Belden1
Description:
20 AWG stranded (19x32) .037" tinned copper conductor, foam FEP insulation, Duobond® II (100%
coverage) plus a tinned copper braid shield (93% coverage), fluorocopolymer jacket.
Usage (Overall)
Suitable Applications:
Thin Ethernet
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
1
20
19x32
TC - Tinned Copper 0.9398
Insulation
Insulation Material:
Insulation Material
Dia. (mm)
FFEP - Foam Fluorinated Ethylene Propylene 2.413
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material
1
2
Bonded Duofoil®
Braid TC - Tinned Copper
Coverage (%)
93
Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVDF - Fluorocopolymer
Overall Cable
Overall Nominal Diameter:
4.064 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-20°C To +150°C
150°C
37.205 Kg/Km
200.169 N
45.720 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
IEEE Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
CMP, CL2P
CMP
IEEE802.3 10Base2
Yes
Yes
Page 1 of 3
02-24-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
89907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Customer Part Number Reference Specification:
RG Type:
Yes
04/01/2005
Yes
Yes
Yes
Yes
DEC Part No. 17-01246-00
58A/U
Flame Test
UL Flame Test:
CSA Flame Test:
NFPA 262
FT6
Suitability
Suitability - Indoor:
Suitability - Outdoor:
Yes
Yes
Plenum/Non-Plenum
Plenum (Y/N):
Non-Plenum Number:
Yes
9907
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm) Tolerance (Ohms)
50
+/- 2
Nom. Inductance:
Inductance (µH/m)
0.208344
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
83.3374
Nominal Velocity of Propagation:
VP (%)
80
Nominal Delay:
Delay (ns/m)
4.16687
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
28.8728
Maximum Loop Resistance:
Resistance (Ohm/km)
50.0024
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
19.0298
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
1
10
50
100
1.41083
4.2653
9.54771
13.7146
Page 2 of 3
02-24-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
89907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet
200
400
700
900
1000
20.0141
30.1852
42.3249
49.215
52.496
Max. Power Rating:
Freq. (MHz) Rating (W)
1
2
10
20
50
100
200
400
700
900
1000
6450
4500
1850
1400
890
640
470
360
290
270
260
Max. Operating Voltage - UL:
Voltage
300 V RMS
Related Documents:
No related documents are available for this product
Put Ups and Colors:
Item #
89907 E4X1000
89907 E4X2500
89907 E4X500
Putup
305 MT
762 MT
152 MT
Ship Weight
10.886 KG
27.216 KG
4.990 KG
Color
GRAY, LIGHT DEC
GRAY, LIGHT DEC
GRAY, LIGHT DEC
Notes
C
CZ
C
Item Desc
#20 FPFA BRD SLF COAX
#20 FPFA BRD SLF COAX
#20 FPFA BRD SLF COAX
Notes:
C = CRATE REEL PUT-UP.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Revision Number: 1
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 09-23-2008
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
02-24-2012