Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8623 Multi-Conductor - Audio, Control and Instrumentation Cable
For more Information
please call
1-800-Belden1
General Description:
16 AWG stranded (19x29) tinned copper conductors, conductors cabled, PVC insulation, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
15
16
19x29
TC - Tinned Copper
Total Number of Conductors:
15
Insulation
Insulation Material:
Insulation Material
Wall Thickness (in.)
PVC - Polyvinyl Chloride .031
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride .060
Overall Cable
Overall Cabling Color Code Chart:
Number Color
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Black
White
Red
Green
Orange
Blue
White/Black
Red/Black
Green/Black
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
Overall Nominal Diameter:
0.694 in.
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
-20°C To +80°C
80°C
288 lbs/1000 ft.
Page 1 of 3
10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8623 Multi-Conductor - Audio, Control and Instrumentation Cable
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
456 lbs.
7 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
Yes
Yes
10/01/2005
Yes
Yes
Yes
Yes
Flame Test
Other Flame Test:
VW-1, FT1
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
19.5
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
4.4
Max. Operating Voltage - Non-UL:
Voltage
600 V RMS
Max. Recommended Current:
Current
5 Amps per conductor @ 25°C
Put Ups and Colors:
Item #
8623 060100
8623 0601000
8623 0602000
8623 060500
8623 0605000
Putup
100 FT
1,000 FT
2,000 FT
500 FT
5,000 FT
Ship Weight
32.300 LB
312.000 LB
602.000 LB
151.500 LB
1,555.000 LB
Color
CHROME
CHROME
CHROME
CHROME
CHROME
C
CZ
Notes
C
C
Item Desc
15 #16 PVC FRPVC
15 #16 PVC FRPVC
15 #16 PVC FRPVC
15 #16 PVC FRPVC
15 #16 PVC FRPVC
Notes:
C = CRATE REEL PUT-UP.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Revision Number: 3
© 2013 Belden, Inc
All Rights Reserved.
Revision Date: 08-22-2012
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
Page 2 of 3
10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8623 Multi-Conductor - Audio, Control and Instrumentation Cable
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
10-30-2013