Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
89503 Multi-Conductor - Computer Cable for EIA RS-232 Applications
For more Information
please call
1-800-Belden1
Description:
24 AWG stranded (7x32) tinned copper conductors, plenum, FEP insulation, twisted pair, overall Beldfoil
shield (100% coverage), 24 AWG stranded TC drain wire, FEP jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
3
24
7x32
TC - Tinned Copper
Insulation
Insulation Material:
Insulation Material
Wall Thickness (mm)
FEP - Fluorinated Ethylene Propylene 0.1524
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24
7x32
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (mm)
FEP - Fluorinated Ethylene Propylene 0.3556
Overall Cable
Overall Nominal Diameter:
4.445 mm
Pair
Pair Color Code Chart:
Number Color
1
2
3
Black & White
Black & Red
Black & Green
Pair Lay Length & Direction:
Lay Length (mm)
25.3999
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-70°C To +200°C
31.996 Kg/Km
173.480 N
45.720 mm
Page 1 of 3
02-24-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
89503 Multi-Conductor - Computer Cable for EIA RS-232 Applications
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
CMP
CMP
Yes
Yes
Yes
04/01/2005
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
C(UL) Flame Test:
NFPA 262
FT6
Plenum/Non-Plenum
Plenum (Y/N):
Non-Plenum Number:
Yes
9503
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/m)
0.55777
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
68.901
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/m)
131.24
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
79.0721
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
52.1679
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
1.5 Amps per conductor @ 25°C
Related Documents:
No related documents are available for this product
Put Ups and Colors:
Item #
89503 002100
Putup
30 MT
Ship Weight
1.814 KG
Color
RED
Notes
C
Item Desc
3 PR #24 FEP FS FEP
Page 2 of 3
02-24-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
89503 Multi-Conductor - Computer Cable for EIA RS-232 Applications
89503 0021000
89503 002500
Notes:
C = CRATE REEL PUT-UP.
305 MT
152 MT
10.433 KG
4.763 KG
RED
RED
C
C
3 PR #24 FEP FS FEP
3 PR #24 FEP FS FEP
Revision Number: 1
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 04-17-2008
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
02-24-2012