Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9432 Multi-Conductor - Audio, Control and Instrumentation Cable
For more Information
please call
1-800-Belden1
General Description:
22 AWG stranded (7x30) tinned copper conductors, conductors cabled, PVC insulation, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
30
22
7x30
TC - Tinned Copper
Total Number of Conductors:
30
Insulation
Insulation Material:
Insulation Material
Wall Thickness (in.)
PVC - Polyvinyl Chloride 0.011
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride .040
Overall Cable
Overall Cabling Color Code Chart:
Number Color
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Black
White
Red
Green
Orange
Blue
White/Black
Red/Black
Green/Black
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
Black/Red
White/Red
Orange/Red
Blue/Red
Red/Green
Orange/Green
Black/White/Red
Page 1 of 3
10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9432 Multi-Conductor - Audio, Control and Instrumentation Cable
23
24
25
26
27
28
29
30
White/Black/Red
Red/Black/White
Green/Black/White
Orange/Black/White
Blue/Black/White
Black/Red/Green
White/Red/Green
Red/Black/Green
Overall Nominal Diameter:
0.400 in.
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-20°C To +80°C
80°C (UL AWM Style 2576)
115 lbs/1000 ft.
270 lbs.
4 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
AWM Specification:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
CMG
CMG
UL Style 2576 (150 V 80°C)
Yes
Yes
Yes
Yes
04/01/2005
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
CSA Flame Test:
UL1685 FT4 Loading
FT4
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/ft)
.17
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
34
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
15.6
Max. Operating Voltage - UL:
Voltage
Page 2 of 3
10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9432 Multi-Conductor - Audio, Control and Instrumentation Cable
300 V RMS (CMG)
150 V RMS (UL AWM Style 2576)
Max. Recommended Current:
Current
1.5 Amps per conductor @ 25°C
Put Ups and Colors:
Item #
9432 060100
9432 0601000
9432 060500
Notes:
C = CRATE REEL PUT-UP.
Putup
100 FT
1,000 FT
500 FT
Ship Weight
12.500 LB
124.000 LB
62.500 LB
Color
CHROME
CHROME
CHROME
C
C
Notes
Item Desc
30#22 PVC PVC
30#22 PVC PVC
30#22 PVC PVC
Revision Number: 2
© 2013 Belden, Inc
All Rights Reserved.
Revision Date: 08-31-2012
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
10-30-2013