P.C.B. COAXIAL CABLE TERMINATIONS
3
INTRODUCTION
3 termination types
• Economic type
• Shielded type
• Half-Shielded type
Features
• Time saving by reduction of terminations and connection outputs.
• Easy assembly : no special tooling is needed for the cable preparation.
• Operationally secure : fitted cable is virtually pull-out proof.
Construction
•
•
•
•
Pitch 5.08 or 2.54. mm
Body : brass.
Insulator PTFE.
Plating :
• Standard : Tin-lead 60/40 (code 110).
• Special : Nickel + Gold (code 131) – consult factory.
Technical characteristics
Environmental and Mechanical
•
•
•
•
Operating temperature :
....................................................................................
Damp heat (severity 5) :
..............................................................................................
Salt spray :
...............................................................................................................
Vibration :
................................................................................................
-55°C + 125°C
21 days
48 hours
10/2000 Hz – 20 G
Electrical
• Working voltage :
...........................................................................................
• Test voltage :
.................................................................................................
• Insulation resistance :
............................................................................................
250 Vrms 50 Hz
500 Vrms 50 Hz
> 1000 MΩ
Nota : All sizes are in millimetres.
4
TYPE INDEX
s
P.C.B. / CABLES TERMINATIONS
REFERENCES
P.C.B. termination
TYPES
SERIES
thickness 1.6 mm
Crimp
Solder
thickness 2.4 mm thickness 3.2 mm
Crimp
Solder
22202
22203
22204
SMT
term.
PAGES
CABLES
GROUPS
Crimp
Solder
6
6
6
6
7
7
7
7
A
D-G
A
D-G
A
D-G
C
C
G
A
B
H
J
D-G
A
A
D-G
D-G
A
B
H
A
B
C-E
22200
22205
22206
22207
22326
ECONOMIC
22300
22327
B 514 C 01 B 514 C 02
B 514 C 03 B 514 C 04
B 514 C 21 B 514 C 22
B 514 C 23 B 514 C 24
B 514 C 27 B 514 C 28
B 514 C 51 B 514 C 52
B 514 C 54
5600 B
8-9
8-9
8-9
8-9
9
10
10
11
11
B 514 C
B 514 C 07 B 514 C 08
B 514 C 31 B 514 C 32
B 514 C 34
SHIELDED
5600
5600 A
22200
22200
22201
B 350 C 01 B 350 C 02
B 350 C 03 B 350 C 04
B 350 C 21 B 350 C 22
B 350 C 23 B 350 C 24
B 350 C 27 B 350 C 28
B 350 C 51 B 350 C 52
B 270 C 01
12-13
12-13
12-13
12-13
14
14
14
HALF-
SHIELDED
B 350 C
B 350 C 07 B 350 C 08
B 350 C 31 B 350 C 32
B 270 C
B 270 C 03
B 270 C 04
5
THREE TERMINATION TYPES
s
ECONOMIC TYPE
22200 and 22300 series
• P .C.B. termination thickness 2.4 mm.
• Cable groups A, C, D, G (see page 2).
•
Solder
braid.
• For 90° cable/p.c.b.
(references 22206, 22207 and 22326).
B 514 C series
• P .C.B. termination thickness 1.6 to 3.2 mm.
• Cable groups A, B, G, H (see page 2).
•
Solder
or
crimp
braid.
s
SHIELDED TYPE
5600 series
• P .C.B. termination thickness 2.4 mm.
• Cable groups A, D, G (see page 2).
•
Solder
braid.
s
HALF-SHIELDED TYPE
22200 series
• P .C.B. termination thickness 2.4 mm.
• Cable groups A, D, G (see page 2).
•
Solder
braid.
B 350 C series
• P .C.B. termination thickness 1.6 to 3.2 mm.
• Cable groups A, B, D, G, H (see page 2).
•
Solder
or
crimp
braid.
B 270 C series
• SMT termination.
• Cable groups A, B, C, E (see page 2).
•
Solder
braid.