Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8233 Coax - RG-11/U Type
For more Information
please call
1-800-Belden1
Description:
14 AWG solid .064" bare copper conductor, gas-injected foam HDPE insulation, bare copper double
shields (95% coverage), polyethylene jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
1
14
Solid
BC - Bare Copper
1.6256
Insulation
Insulation Material:
Insulation Material
Dia. (mm)
Gas-injected FHDPE - Foam High Density Polyethylene 7.239
Inner Shield
Inner Shield Material:
Type Inner Shield Material Coverage (%)
Braid BC - Bare Copper
95
Inner Jacket
Inner Jacket Material:
Inner Jacket Material Nom. Dia. (mm)
PE - Polyethylene
9.271
Outer Shield
Outer Shield Material:
Type Outer Shield Material Coverage (%)
Braid BC - Bare Copper
80
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PE - Polyethylene
Overall Cable
Overall Nominal Diameter:
12.065 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
Non-UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-55°C To +80°C
80°C
166.678 Kg/Km
756.194 N
254 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
EU CE Mark:
EU Directive 2000/53/EC (ELV):
No
Yes
Page 1 of 3
02-01-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8233 Coax - RG-11/U Type
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
RG Type:
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
11/U
Suitability
Suitability - Indoor:
Suitability - Outdoor:
Suitability - Aerial:
Suitability - Burial:
Yes
Yes
Yes, when supported by a messenger wire
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
75
Nom. Inductance:
Inductance (µH/m)
0.318257
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
52.8241
Nominal Velocity of Propagation:
VP (%)
84
Nominal Delay:
Delay (ns/m)
3.9372
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
8.2025
Nom. Inner Shield DC Resistance:
DCR @ 20°C (Ohm/km)
5.2496
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
4.5934
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
1
3.6
10
71.5
135
270
360
0.6562
0.9843
1.3124
3.6091
4.9215
7.5463
8.8587
Page 2 of 3
02-01-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8233 Coax - RG-11/U Type
540
720
750
1000
1500
2250
3000
11.4835
13.7802
14.1083
17.0612
23.2951
31.4976
39.372
Max. Operating Voltage - Non-UL:
Voltage
300 V RMS
Minimum Return Loss:
Start Freq. (MHz) Stop Freq. (MHz) Min. RL (dB)
5
851
850
3000
21
15
Sweep Test
Sweep Testing:
100% Sweep tested 5 MHz to 3 GHz.
Related Documents:
No related documents are available for this product
Put Ups and Colors:
Item #
8233 0101000
8233 0102000
8233 010500
Notes:
C = CRATE REEL PUT-UP.
Putup
305 MT
610 MT
152 MT
Ship Weight
53.978 KG
108.863 KG
28.576 KG
Color
BLACK
BLACK
BLACK
Notes
C
C
C
Item Desc
RG-11/U TYPE TRIAX
RG-11/U TYPE TRIAX
RG-11/U TYPE TRIAX
Revision Number: 1
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 04-06-2009
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Page 3 of 3
02-01-2012