SPECIFICATION CONTROL DRAWING
TITLE
FLDW+1321
Date
TWO CONDUCTOR CABLE, SHIELDED, JACKETED, 600 VOLT
7-14-10
Revision
D
The complete requirements for procuring the cable described herein shall consist of this document and the issue in effect of
Raychem Specification 44 and UL Subject 758, Style 20889, File E303150 and carries UL labels to this effect.
COMPONENT WIRES - FLDW+0311
SHIELD -TIN-COATED COPPER
JACKET - RADIATION-CROSSLINKED,
MODIFIED PVDF
TABLE I. CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
FLDWC1321-26-*
FLDWC1321-24-*
FLDWC1321-22-*
FLDWC1321-20-*
FLDWC1321-18-*
FLDWC1321-16-*
FLDWC1321-14-*
FLDWC1321-12-*
FLDWD1321-12-*
FLDWD1321-10-*
FLDWE1321-8-*
CONDUCTOR
SIZE
(AWG)
26
24
22
20
18
16
14
12
12
10
8
SHIELD
SIZE
(AWG)
36
36
36
36
36
36
36
36
36
36
36
JACKET THICKNESS
(in.)
MINIMUM
.008
.008
.008
.008
.008
.008
.008
.008
.008
.008
.008
NOMINAL
.010
.010
.010
.010
.010
.010
.010
.010
.010
.010
.010
OUTSIDE DIAMETER
(in.)
NOMINAL
.121
.133
.149
.165
.187
.203
.237
.285
.275
.333
.445
MAXIMUM
.127
.140
.156
.173
.196
.213
.249
.299
.289
.350
.467
TARGET
WEIGHT
(lbs/1000 ft.)
10.6
13.1
16.5
20.9
27.7
33.1
45.5
68.7
63.1
94.5
151.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/
COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
The TE logo, Tyco Electronics and Raychem are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
Page 1 of 2
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2006-2010 Tyco Electronics Corporation. All rights reserved.
Revision
SCD
SPECIFICATION CONTROL DRAWING
Page 2 of 2
D
FLDW+1321
TABLE II. CABLE PERFORMANCE DETAILS
BEND TESTING
PART NUMBER
1/
MANDREL DIAMETER
(inch) (±3%)
ACCELERATED AGING
FLDWC1321-26-*
FLDWC1321-24-*
FLDWC1321-22-*
FLDWC1321-20-*
FLDWC1321-18-*
FLDWC1321-16-*
FLDWC1321-14-*
FLDWC1321-12-*
FLDWD1321-12-*
FLDWD1321-10-*
FLDWE1321-8-*
3.00
6.00
6.00
6.00
6.00
6.00
6.00
10.0
10.0
10.0
18.0
COLD
BEND
3.00
6.00
6.00
6.00
6.00
6.00
6.00
10.0
10.0
10.0
18.0
WEIGHT
(lb) (±3%)
ACCELERATED AGING
.375
.375
.375
.500
.500
1.00
1.00
1.50
1.50
2.00
2.00
COLD
BEND
1.50
1.50
3.00
3.00
3.00
3.00
9.00
9.00
9.00
9.00
15.0
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 125°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 2500 volts (rms), 60 Hz, 1 minute
FLAMMABILITY: 30 seconds (maximum); 3 in. (maximum); no flaming of facial tissue
INSULATION ELONGATION AND TENSILE STRENGTH: Test per WCD 3106
Primary Insulation,
Elongation, 150% (minimum)
Tensile Strength, 2500 lbf/in² (minimum)
JACKET COLOR: White preferred
JACKET CONCENTRICITY: 70% (minimum)
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 200% (minimum)
Tensile Strength, 4500 lbf/in² (minimum)
JACKET FLAWS:
Spark Test, 1.5 kV (rms)
Impulse Dielectric Test, 6.0 kV (peak)
JACKET WALL THICKNESS: Measure per WCD 3106
Lower Limit: Per Table I
Minimum Average: 0.008 inch
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHIELD COVERAGE: 85% (minimum)
VOLTAGE WITHSTAND (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute
PART NUMBER:
The “+” in the part number in the upper right hand corner shall be replaced with a letter designator to
define conductor stranding (see part numbers in table).
C = 19 Strands D = 37 Strands E = Rope Lay
The “*” in the part numbers on Tables I and II shall be replaced by color code designators with a slash
separating the component wire colors and a dash separating the component wire colors from the jacket color.
1/
Example: AWG 16, 19 strands, black and brown component wires; white jacket: FLDWC1321-16-0/1-9
1/
See footer section on page 1