SPECIFICATION
3
4
1,0
5,0
detail A
Land Pattern
16,0 ± 0,1
12,0 ± 0,1
+0,1
-0,05
1
+0,0
-0,3
2
1
2
15,3
5,0
>Rating :
>Contact Resistance :
Initial :
After Life Test :
>Insulation Resistance :
>Dielectric Strength :
>Stroke :
>Bounce :
MATERIAL
50mA, 12VDC
100mΩ max.
2Ω max.
min. 100MΩ at 500VDC
250VAC for 1 minute
0.3 ± 0.1mm
10ms max.
0
3
0,5 max.
4
1,8
O
7,0
O
6,8
0,3 ± 0,1
>Cover :
>Stem :
>Frame :
>Contact :
>Terminal :
SOLDERING INFORMATION
Stainless Steel
PA9T UL 94 V-0
PA9T UL 94 V-0, color Black
Stainless Steel with Silver
Copper Alloy with Silver
Schematic
8,5
3,5
A
>Terminal in SMD version
>Reflow soldering according to JEDEC J-STD 020 Hot Air
>Hand soldering under 350°C for 3 sec. max
ENVIRONMENTAL
Storage condition :
Operation condition :
Compliance :
PACKAGING INFORMATION
>Tape & Reel
-40°C ~ +85°C
-40°C ~ +85°C
Lead Free , ROHS , Reach
q
8,6
q
12,0
Scale - 2:1
Part number
430 172 085 816
430 162 085 826
Force
160g ± 50gf
260g ± 70gf
GENERAL TOLERANCE
Color of Stem
Black
White
PROJECTION
METHOD
Life cycle
500,000
300,000
SCALE
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
com. +49 79 42 945 - 0
www.we-online.de
eiSos@we-online.de
CREATED
CHECKED
LeTe
DESCRIPTION
JLi
DIN ISO 2768-1m
2:1
TECHNICAL REFERENCE
WS-TASV
Tact Switch, SMD version
SIZE
STATUS
_________
ORDER CODE
4301x20858x6
DATE
BUSINESS UNIT
PAGE
REV.
FILE
DATE
BY
12x12 mm
Released
2015-10-27
eiCan
1 /1
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.