Operating at frequencies up to 2 MHz, VI-200 family converters offer exceptional power
density, efficiency, noise performance, reliability and ease of use. Booster modules
(VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output
requirements. One or more boosters may be used to create synchronous arrays capable of
supplying several kilowatts of output power.
The flexibility of Vicor’s power components is also available in half-size, half-power
VI-J00 MiniMods.
Part Numbering
VI
—
2
6
1
—
C
W
Family
VI
= Non-RoHS
VE
= RoHS
Series
2
= 200
B
= Booster
0
= 12 V
V
= 24 V
1
= 24 V
W
= 24 V
2
= 36 V
3
= 48 V
Input
N
= 48 V
4
= 72 V
T
= 110 V
5
= 150 V
6
= 300 V
7
= 150/300 V
Z
= 2V
Y
= 3.3 V
0
= 5V
X
= 5.2 V
W
= 5.5 V
V
= 5.8 V
T
= 6.5 V
R
= 7.5 V
Output
M
= 10 V
1
= 12 V
P
= 13.8 V
2
= 15 V
N
= 18.5 V
3
= 24 V
L
= 28 V
J
= 36 V
K
= 40 V
4
= 48 V
H
= 52 V
F
= 72 V
D
= 85 V
B
= 95 V
Grade
E
= –10 to 85°C
C
= –25 to 85°C
I
= – 40 to 85°C
M
= –55 to 85°C
≥ 5V
Power
< 5V
U
= 40 A
V
= 30 A
W
= 20 A
X
= 15 A
Y
= 10 A
U
= 200 W
V
= 150 W
W
= 100 W
X
= 75 W
Y
= 50 W
Note: For
additional
packaging options,
please see page 4.
Maximum Power Available for VI-2xx-xx
[a]
Input
Voltage
Nom. (Range)
12 (10-20)
24 (10-36)
24 (21-32)
24 (18-36)
36 (21-56)
48 (42-60)
48 (36-76)
72 (55-100)
110 (66-160)
150 (100-200)
150 (100-375)
300 (200-400)
[a]
[b]
Output
Transient
[b]
22
n/a
36
n/a
60
72
n/a
110
n/a
215
n/a
425
Vin
2
Designators
Z
0
V
1
W
2
3
N
4
T
5
7
6
X
--
U
V
W
U
V
U
V
U
W
U
3.3
Y
X
X
U
V
V
U
U
U
V
U
W
U
5
0
X
Y
U
V
W
U
U
U
V
V
Y
U
Vout Designators
5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 36
X
X
Y
U
V
W
U
U
U
V
V
Y
U
W
X
Y
U
V
W
U
U
U
V
V
Y
U
[c]
[d]
Low Line
75%
Max Power
n/a
n/a
18
n/a
18
36
n/a
45
n/a
85
[c]
40 48 52 72 85 95
K
X
X
U
V
W
U
U
U
V
U
W
U
4
X
X
U
V
W
U
U
U
V
U
W
U
H
X
--
U
V
W
U
U
U
V
U
W
U
F
X
--
U
V
--
U
U
U
V
U
--
U
D
X
--
U
V
--
U
U
U
--
U
--
U
B
X
--
U
V
--
U
U
U
--
U
--
U
V
X
Y
U
V
W
U
U
U
V
V
Y
U
T
X
Y
V
W
W
U
U
V
W
V
W
V
R
X
X
V
W
W
U
U
V
W
V
W
V
M
X
X
U
V
W
U
U
U
V
U
W
U
1
X
X
U
V
W
U
U
U
V
U
W
U
P
X
X
U
V
W
U
U
U
V
U
W
U
2
X
X
U
V
W
U
U
U
V
U
W
U
N
X
X
U
V
W
U
U
U
V
U
W
U
3
X
X
U
V
W
U
U
U
V
U
W
U
L
X
X
U
V
W
U
U
U
V
U
W
U
J
X
X
U
V
W
U
U
U
V
U
W
U
n/a
170
[d]
For
additional
output power, “booster” modules
are available.
(VI-Bxx-xx)
Transient voltage for 1 second.
15 Vout, 200 W models
are
limited to 90 Vdc
15 Vout, 200 W models
are
limited to 185 Vdc
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-200 DC-DC Converters 50 to 200 Watts
Rev. 3.3
Page 1 of 5
Set your site on VICOR at vicorpower.com
CONVERTER SPECIFICATIONS
(typical at T
BP
= 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
VI-200 E-Grade
Parameter
Inrush charge
Input reflected
ripple current – pp
Input ripple rejection
Min
Typ
120 x 10
10%
25+ 20 Log Vin
-6
VI-200 C-, I-, M-Grade
Max
Min
Typ
120 x 10
10%
-6
Max
200 x 10
-6
Units
Coulombs
I
IN
Test Conditions
Nominal line
Nominal line, full load
120 Hz, nominal line
2400 Hz, nominal line
( )
Vout
( )
20+ 20 Log
(
Vin
)
30+ 20 Log Vin
Vout
Vout
dB
dB
2
Watts
No load power dissipation
1.35
2
1.35
OUTPUT CHARACTERISTICS
VI-200 E-Grade
Parameter
Setpoint
accuracy
Load/line regulation
Load/line regulation
Output temperature drift
Long term drift
Output ripple – pp:
2 V, 3.3 V
5V
10 – 95 V
Trim range
[a]
Total remote
sense compensation
OVP set point
Current limit
Short circuit current
[c]
[a]
VI-200 C-, I-, M-Grade
Max
2%
0.5%
1%
Min
Typ
0.5%
0.05%
0.2%
0.01
0.02
150
5%
3%
60
2%
0.75%
50%
0.5
100
3%
1.5%
110%
Max
1%
0.2%
0.5%
0.02
Units
V
NOM
V
NOM
V
NOM
% / °C
%/1K hours
mV
V
NOM
V
NOM
V
NOM
Volts
125%
[b]
135%
125%
130%
V
NOM
I
full load
I
full load
0.25 V max. neg. leg
Recycle power
Automatic restart
Automatic restart
20 MHz
bandwidth
20 MHz
bandwidth
20 MHz
bandwidth
LL to HL, 10% to Full Load
LL to HL, No Load to 10%
Over rated temp.
Test Conditions
Min
Typ
1%
0.02
0.02
50%
0.5
125%
[b]
105%
20%
110%
115%
135%
140%
105%
20%
[b]
[c]
10 V, 12 V, 13.8 V, 15 V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range.
3.3 V output trim range 2.20 to 3.63 V, 95 V output –50 + 0% trim range.
131% nominal for
booster
modules.
Output voltages of 3.3 V or 5 V incorporate foldback current limiting; For output voltages from 5.2 V to 7.5 V consult factory; All other outputs provide constant current limiting.
CONTROL PIN SPECIFICATIONS
VI-200 E-Grade
Parameter
Gate out impedance
Gate in impedance
Gate in open circuit voltage
Gate in low threshold
Gate in low current
Power sharing
accuracy
0.95
0.65
6
1.05
0.95
Min
Typ
50
1000
6
0.65
6
1.05
Max
Min
VI-200 C-, I-, M-Grade
Typ
50
1000
6
Max
Units
Ohms
Ohms
Volts
Volts
mA
Use open collector
Test Conditions
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-200 DC-DC Converters 50 to 200 Watts
Rev. 3.3
Page 2 of 5
Set your site on VICOR at vicorpower.com
CONVERTER SPECIFICATIONS (cont.)
DIELECTRIC WITHSTAND CHARACTERISTICS
VI-200 E-Grade
Parameter
Input to output
Output to
baseplate
Input to
baseplate
Min
3,000
500
1,500
Typ
Max
Min
3,000
500
1,500
VI-200 C-, I-, M-Grade
Typ
Max
Units
V
RMS
V
RMS
V
RMS
Test Conditions
Baseplate earthed
THERMAL CHARACTERISTICS
VI-200 E-Grade
Parameter
Efficiency
Baseplate to sink
thermal impedance
Thermal shutdown
[d]
(Drivers only)
[d]
VI-200 C-, I-, M-Grade
Max
Min
Typ
80 – 90%
0.07
105
90
95
105
°C/Watt
°C
With Vicor P/N 20266
Cool
and
recycle power
to restart
Max
Units
Test Conditions
Min
Typ
78 – 88%
0.07
90
95
No overtemp protection in
booster
modules.
MECHANICAL SPECIFICATIONS
VI-200 E-, C-Grade
Parameter
Weight
Min
5.7
(160.2)
Typ
6.3
(178)
Max
6.9
(195.8)
Min
6.6
(187.2)
VI-200 I-, M-Grade
Typ
7.3
(208)
Max
8.1
(228.8)
Units
Ounces
(Grams)
Test Conditions
PRODUCT GRADE TEMPERATURES
Parameter
E
C
I
M
Storage
-20 to +100
-40 to +100
-55 to +100
-65 to +100
Operating
-10 to + 85
-25 to + 85
-40 to + 85
-55 to + 85
Units
°C
°C
°C
°C
Overtemperature shutdown
95°C typical (recycle power
to restart)
Notes
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-200 DC-DC Converters 50 to 200 Watts
Rev. 3.3
Page 3 of 5
Set your site on VICOR at vicorpower.com
MECHANICAL DRAWING
.50
(12,7)
.30±.015
(7,6)±(0,38)
1.80
(45,7)
4.60
(116,8)
3.60
(91,4)
Standard
0.080 (2,0) Dia (2) places
Solder plate over copper
alloy
RoHS
0.080 (2,0) Dia (2) places
Matte tin over copper
alloy
4
2.10
(53,3)
3
9
VI-200
2
1
8
7
6
5
1.40
1.00 (35,6)
.70 (25,4)
.40 (17,8)
(10,2)
.35±.015
(8,9)±(0,38)
.15
(3,8)
FULL R
.15
(3,8)
Product ID
this surface
Pin # Function
1
+In
2
Gate In
3
Gate Out
4
-In
5
+Out
6*
+Sense
7*
Trim
8*
-Sense
9
-Out
* Do not connect on
booster
modules
RoHS
.040 (1,0) Dia (7) places
Matte tin over copper
alloy
2.40
(61,0)
Standard
.040 (1,0) Dia (7) places
Solder plate over copper
alloy
4.20
(106,7)
.22
(5,6) MIN
.30
(7,6) Min
1.75 Max.
(44,5)
.50
(12,7)
.12
(3,0)
+.030 (0,76)
-.000 (0)
.01
Aluminum Base
PACKAGING OPTIONS
SlimMod
Flangeless package
FinMod
Flangeless package with integral heat sink
MegaMod
Chassis mount
alternatives,
one, two,
or three outputs:
up
to 600 W
4.60"L x 1.80"W x 0.50"H
(116,8 x 45,7 x 12,7 mm)
To order the SlimMod configuration add the suffix “ – S” to
the standard module part number.
Qty (2) grounding clips are included with each SlimMod
P/N 32187
Longitudinal, 0.25"(6.35 mm) fins — add suffix “– F1”
Longitudinal, 0.50"(12.7 mm) fins — add suffix “– F2”
1 up – 4.9¨ x 2.5¨ x 0.62¨ (124,4 x 63,5 x 15,7 mm)
2 up – 4.9¨ x 4.9¨ x 0.62¨ (124,4 x 124,4 x 15,7 mm)
3 up – 4.9¨ x 7.3¨ x 0.62¨ (124,4 x 185,4 x 15,7 mm)
BusMod
Transverse, 0.25"(6.35 mm) fins — add suffix “– F3”
Transverse, 0.50"(12.7 mm) fins — add suffix “– F4”
Available with longitudinal or transverse fins of 0.25"(6.35
mm) or 0.50"(12.7 mm) height. Add the appropriate suf-
fix to the module part number.
Qty (4) grounding clips are included with each FinMod
F1, F2 P/N 32185
F3, F4 P/N 32186
4.60"L x 2.40"W x 1.08"H
(116,8 x 61,0 x 27,4 mm)
To order the BusMod fully assembled, add suffix “–B1”
to the standard module part number.
To order the BusMod separately:
Full-sized BusMod — P/N 06322
See BusMod Mechanical Drawings for more details.
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-200 DC-DC Converters 50 to 200 Watts
Rev. 3.3
Page 4 of 5
Set your site on VICOR at vicorpower.com
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked
and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality con-
trols are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements,
testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DIS-
CLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FIT-
NESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MAT-
TER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be
liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and
assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor prod-
ucts and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing
and operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to
the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause
the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor
products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the prod-
ucts described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
ABI Research最近评选并公布了全球超高频无源和高频无源 RFID芯片的前十大制造商。 前十大超高频无源芯片制造商是: 前十大高频无源芯片制造商是: 超高频的得奖名单并不出人意外,因为实际上似乎总是前三家公司获得大订单。ABI分析家 Mike Liard称,ABI很容易就评选出 Alien、Avery,和 Raflatac为全球...[详细]
“tensymetry”这个词在《韦伯斯特词典》中没有解释,但在医学界却广为人知。由Tensys Medical Systems公司开发的tensymetry是一种使用生物机械、电气、软件工程的专有组合技术。利用这三种强大的技术,你可在手术室内对病人的心跳血压进行精确、连续、实时和非侵入性测量。 该技术结出的果实就是该公司的T-line Tensymeter产品。该产品线的最新进展是去年...[详细]